How to Mount Installation Plate

The wall you select should be strong and solid enough
to prevent vibration
1. Mount the installation plate on the wall with
type "A" screws. If mounting the unit on a concrete
wall, use anchor bolts.
• Mount the installation plate horizontally by aligning the
centerline using a level.
2. Measure the wall and mark the centerline. It is also important to use caution concerning the location of the instal-
lation plate-routing of the wiring to power outlets is through the walls typically. Drilling the hole through the wall
for piping connections must be done safely.
CHASSIS
(Grade)
A
SE
65(2.6)
110(4.3)

Drill a Hole In The Wall

• Drill the piping hole with a ø70mm(2.76in) hole
core drill. Drill the piping hole at either the right
or the left with the hole slightly slanted to the out-
door side.
Distance [mm(in)]
B
C
D
85(3.3)
110(4.3)
Chassis
Hook
Installation plate
D
C
Ø70mm
Left rear piping
WALL
Indoor
Installation
Installation Plate
Type "A"
B
A
Ø70mm
Right rear piping
Outdoor