8. Wiring Diagrams

ART COOL Type

FAN
MOTOR
1(L) 2(N)
TO OUTDOOR UNIT
3854A20135Y
CONNECTOR NUMBER
CN-POWER
CN-MOTOR
CN-D1
CN-D2
CN-LR1
CN-LR2
CN-UD
CN-TH1
CN-TH2
34
MPS Variable Multi Split System(50Hz, R410A)
AC PWB ASM
WH
BK
YL
RD
Z
FUSE
250V 3.15A
3
4
SAFETY S/W
SAFETY S/W
LOCATION
AC POWER SUPPLY
BLDC FAN MOTOR OUTPUT
DISPLAY
DISPLAY
STEP MOTOR
STEP MOTOR
STEP MOTOR
ROOM/PIPE SENSOR
DISCHARGE PIPE SENSOR
DC PWB ASM
THERMISTOR(OUT-PIPE)
THERMISTOR(IN-PIPE)
THERMISTOR(ROOM)
STEP
MOTOR
STEP
MOTOR
STEP
MOTOR
RD
H.V.
BK
ASM
CN-D1(WH) CN-D2(WH)
DISPLAY
CONNECT
PCB
PCB ASM
ASM
STEP
FORCE S/W
MOTOR
PLASMA
AIR CLEAN