INSTALLATION AND OWNER GUIDE
Model 349
RADIANT / CONVECTOR GAS FIRE
Fitted with one of the following fascia.
Brava, Charm
Esquire.
(GC No. 32-032-91)
We trust that this guide gives
sufficient details to enable this
appliance to be installed and
maintained satisfactorily. However, if
further information is required, our
Valor Fires Technical Helpline will
be pleased to help.
Telephone 0844 8711 565 (National
call rates apply in the United
Kingdom).
In the Republic of Ireland
Telephone 0044 844 8711 565.
INSTALLER: Please leave this guide with the owner
©
Baxi Heating U.K. Limited 2009.
or
5135979/01

Advertisement

Table of Contents
loading

Summary of Contents for Valor Fires 349

  • Page 1 However, if further information is required, our Valor Fires Technical Helpline will be pleased to help. Telephone 0844 8711 565 (National call rates apply in the United Kingdom).
  • Page 2 Warning: Any person who does any unauthorised act in relation to a copyright work may be liable to criminal prosecution and civil claims for damages. Valor Fires, Erdington, Birmingham B24 9QP www.firesandstoves.co.uk Because our policy is one of constant development and improvement, details may vary slightly from those given in this publication ©...
  • Page 3 BS EN ISO 9001 quality system accepted by the British Standards Institute. The Highest Standards Valor Fires is a member of SBGI and HHIC (Heating and Hot water Industry Council) that work to ensure high standards of safety, quality and performance. Careful Installation...
  • Page 4 INSTALLER GUIDE INSTALLER GUIDE FOR OWNER GUIDE SEE PAGES 32 TO 47 © Baxi Heating U.K. Limited 2009. Page 4...
  • Page 5: Table Of Contents

    INSTALLER GUIDE CONTENTS Section Heading Page INSTALLER GUIDE 4 - 31 OWNER GUIDE 32 - 47 1. SAFETY 2. LIST OF ACCESSORIES 3. APPLIANCE DATA AND EFFICIENCY 3.1 Appliance data. 3.2 Efficiency. 4. GENERAL INSTALLATION REQUIREMENTS 4.1 Regulations, Standards and Law. 4.2 Ventilation.
  • Page 6: Installer Guide

    INSTALLER GUIDE CONTENTS (Continued) Section Heading Page 7. CONTROL & PRESSURE CHECKS 7.1 Check control settings. 7.2 Flame supervision and spillage monitoring system. 7.3 Check reference pressure. 8. FASCIA FITTING 8.1 To fit the closure plate baffle. 8.2 To fit the fascia. 9.
  • Page 7: Safety

    INSTALLER GUIDE 1. SAFETY Installer Before continuing any further with the installation of this appliance please read the following guide to manual handling: The lifting weight (kg) of this appliance is as below: Model Heat Engine Fascia Brava 10.15 7.39 Charm 10.15 7.39...
  • Page 8: Appliance Data And Efficiency

    : Model Efficiency % (Gross) 349 Brava, Charm & Esquire The gross calorific value of the fuel has been used for this efficiency calculation. The test data from which it has been calculated has been certified by GL Industrial services (0087).
  • Page 9: General Installation Requirements

    INSTALLER GUIDE 4. GENERAL INSTALLATION REQUIREMENTS 4.1 Regulations, Standards and Law. The installation must be in accordance with these instructions. For the user’s protection, in the United Kingdom it is the law that all gas appliances are installed by competent persons in accordance with the current edition of the Gas Safety (Installation and Use) Regulations.
  • Page 10: Ventilation

    INSTALLER GUIDE b) All relevant national and local rules in force. c) The current building regulations. Where no specific instructions are given, reference should be made to the relevant British Standard Code of Practice. 4.2 Ventilation. Normal adventitious ventilation is usually sufficient to satisfy the ventilation requirements of this appliance.
  • Page 11: Fireplace Preparation

    INSTALLER GUIDE 4.6 Fireplace preparation. 4.6.1 The appliance can be fitted to a purpose made proprietary class “O” 150°C surround. 4.6.2 If the fireplace opening is an underfloor draught type, it must be sealed to stop any draughts. 4.6.3 The front of the fireplace should be flat over an area sufficient to ensure a good seal with the closure plate.
  • Page 12: Fireplace Clearances

    INSTALLER GUIDE 4.7 Fireplace clearances. 4.7.1 The minimum allowable distance from the outside of the appliance fascia to a corner wall having combustible material or any other combustible surface which projects beyond the front of the appliance is 50mm at either side (See figure 2). Although no side clearance is necessary to non-combustible surfaces we recommend a 100mm clearance for service access to fascia side fixing.
  • Page 13: The Flue Spigot

    250mm downward measured from the bottom of the flue spigot (See figure 4). 4.8.2 A spigot extension is available (Valor Fires part number 0595191). When fitted this shall extend through the closure plate for at least 38mm and have a minimum clearance of 50mm from the end to any surface.
  • Page 14: The Hearth

    INSTALLER GUIDE 4.9. The hearth. The appliance must be mounted on a non-combustible hearth except when the conditions in section 4.10.3 are met (N.B. conglomerate marble hearths are considered as non-combustible). The hearth must be at least 680mm wide x 300mm deep.
  • Page 15 INSTALLER GUIDE The fireplace opening must be within the following dimensions: Precast flue Width Height Max. 440mm Max. 610mm Min. 305mm Min. 544mm The total height of the closure plate is 660mm and will accommodate a maximum opening height of 650mm (This allows a 10mm overhang). Heights above 580mm (Inclusive of sealing tape) will leave the sealing tape and closure plate visible above the appliance.
  • Page 16: Flues

    INSTALLER GUIDE Wall mounting to a pre cast flue. Important: If the base of the opening is above the finished floor level it must be a maximum 350mm from the finished floor level. This will ensure that the air relief hole in the closure plate is not covered or reduced.
  • Page 17: Pre-Installation Preparation

    INSTALLER GUIDE terminal, shall be not less than 3m in actual vertical height. When calculated in accordance with BS 5440: Part 1 Annex B, the minimum equivalent height of the flue shall be 2.0m of 125mm dia. flue pipe. The flue must be clear of any obstruction and its base must be clear of debris. The flue must be completely sealed so that combustion products do not come into contact with combustible materials outside the chimney.
  • Page 18: Fitting The Battery To Electronic Ignition Models

    INSTALLER GUIDE 5.3 Fitting the battery to electronic ignition models. 1. At the front of the electronic spark generator there is a removable circular battery cover. Unscrew the cover in an anticlockwise direction. 2. Remove any protective film from the battery and place into the generator.
  • Page 19: Fitting The Closure Plate

    INSTALLER GUIDE 5.5 Fireplace flue pull. Close all doors and windows in the room in which the appliance is to be installed. After confirming with a match that smoke is drawn into the flue, light a 13 gram smoke pellet and check that there is a definite flow through the flue. Verify outside that the smoke exits from one terminal only and that the termination is suitable.
  • Page 20 INSTALLER GUIDE 5.6.1 Hearth mounting (See figure 8). The closure plate must be fitted and sealed to the hearth and fireplace opening using a suitable heat resistant material. If necessary cut the closure plate but make sure that it overlaps the fireplace opening sufficiently to allow satisfactory sealing.
  • Page 21: Appliance Installation

    INSTALLER GUIDE 5.6.3 Check the flue pull with closure plate fitted by applying a lighted match or smoke match to the flue spigot opening in the closure plate and observe the smoke. If there is a definite flow continue with the installation. If not check the fitting of the closure plate.
  • Page 22: Wall Mounting

    INSTALLER GUIDE 6.3 Wall mounting. The fixing hole positions in relation to the flue spigot opening are shown in figure 12. These hole positions are for the upper fixing brackets shown in figure 13 and the lower fixing holes in the back panel.
  • Page 23: Flue Restrictor Adjustment

    INSTALLER GUIDE 6.6 Flue restrictor adjustment. (See figure 14). The appliance has an integral adjustable flue draught restrictor. This is supplied set in the fully open (unrestricted) position and in most cases no adjustment should be necessary. It can be reset to a fully restricted position if the flue draught is excessive.
  • Page 24: Control & Pressure Checks

    INSTALLER GUIDE 7. CONTROL & PRESSURE CHECKS Please note: When operating the fire for the first time, some vapours may be given off which could set off smoke alarms in the vicinity. These vapours are quite normal with new appliances. They are totally harmless and will disappear after a few hours use. 7.1 Check control settings.
  • Page 25: Flame Supervision And Spillage Monitoring System

    INSTALLER GUIDE 7.2 Flame supervision and spillage monitoring system. The pilot unit incorporates a system that will automatically shut off the gas supply if the pilot flame goes out or if there is insufficient oxygen due to spillage or lack of ventilation.
  • Page 26: Fascia Fitting

    INSTALLER GUIDE 8. FASCIA FITTING Before continuing with the installation of this appliance it is important that the information contained on the back pages of the Owner guide is completed. 8.1 To fit the closure plate baffle. The closure plate baffle is supplied with the fire and is intended for use where the height of the closure plate and sealing tape is greater than 580mm.
  • Page 27: Spillage Check

    INSTALLER GUIDE 9. SPILLAGE CHECK A spillage check must be made before leaving the installed appliance with the customer. Make this with all radiants and complete fascia in position. 1. Close all doors and windows in the room containing the fire. 2.
  • Page 28: Final Review

    INSTALLER GUIDE 10. FINAL REVIEW COMPLETE THE INFORMATION IN THE WARRANTY AND SERVICE SECTION OF THE OWNER GUIDE (See last pages of the OWNER guide). Make sure that the dress guard is securely in position. Recheck the operation of the fire at all control positions. Explain to the customer the operation of the ignition system and that manual ignition models are fitted with a two-spark ignition system (See section 7.1 point 3).
  • Page 29: Servicing & Parts Replacement

    INSTALLER GUIDE 11. SERVICING & PARTS REPLACEMENT Always turn off the gas supply and allow the appliance to cool completely before commencing any servicing (The appliance inlet “T” connector incorporates an isolating valve). It is recommended that, at least once a year, the appliance is disconnected and the catchment space behind the closure plate checked and cleared of any debris.
  • Page 30: To Replace The Pilot Unit

    INSTALLER GUIDE 11.3 To replace the pilot unit. 1. Remove the fascia as section 11.2. 2. Disconnect the thermocouple connection at the bottom of the gas tap. 3. Disconnect the pilot pipe from the gas tap. It is the upper connection at the right side of the tap.
  • Page 31: To Grease The Gas Tap

    INSTALLER GUIDE It is important to note the orientation of the ‘D’ flat at the top of the spindle as it will need to be replaced in the same way. 3. Electronic ignition: Remove the lower ‘R’ clip from the base of the spindle assembly.
  • Page 32: Owner Guide

    OWNER GUIDE OWNER GUIDE FOR WARRANTY AND SERVICE INFORMATION SEE PAGES 41 TO 47 © Baxi Heating U.K. Limited 2009. Page 32...
  • Page 33 OWNER GUIDE LIST OF CONTENTS Section Page SAFETY GAS CONSUMPTION APPLIANCE DIMENSIONS OPERATING YOUR FIRE The Oxysafe flame sensing and flue blockage safety system. To light the fire (Manual ignition). To light the fire (Electronic ignition). Settings. To turn the fire off. Lighting with a match or taper.
  • Page 34 OWNER GUIDE SAFETY IF YOU SMELL GAS DON’T SMOKE. EXTINGUISH ALL NAKED FLAMES. DON’T TURN ELECTRICAL SWITCHES ON OR OFF. TURN OFF THE GAS SUPPLY AT THE METER. OPEN DOORS AND WINDOWS TO GET RID OF THE GAS. IMMEDIATELY CALL THE GAS EMERGENCY SERVICE FROM A NEIGHBOURS PHONE - SEE YOUR LOCAL TELEPHONE DIRECTORY.
  • Page 35 OWNER GUIDE Do provide a suitable guard that complies with BS 8423 for the protection of young children, the elderly, the infirm and pet animals Although this fire conforms to all the applicable standards, it is a heating appliance and certain parts of its surface will become hot).
  • Page 36 OWNER GUIDE APPLIANCE DIMENSIONS Model Dimension ‘A’ (mm) Dimension ‘B’ (mm) Dimension ‘C’ (mm) Brava Charm Esquire Figure 2. Dimensions and clearances OPERATING YOUR FIRE PLEASE NOTE When operating your fire for the first time, some vapours may be given off which may cause a slight odour and could possibly set off any smoke alarms in the immediate vicinity.
  • Page 37 OWNER GUIDE This device incorporates a probe that senses that the heat from the pilot flame is correct. If this probe is cool, the device will prevent any gas flow unless the control knob is held down at the ignition position. If, for any reason, the flames go out when the fire is hot or if the fire is turned off when hot, always wait at least three minutes before attempting to relight.
  • Page 38 OWNER GUIDE Settings. The control settings are shown in the table below: Control Knob Radiants Condition Position Centre radiants on low. Outer radiants off. (The right hand centre radiant will glow slightly more than than the left hand centre radiant due to the pilot flame) Centre radiants fully on.
  • Page 39 REPLACING THE RADIANTS (See figure 5). Always use the correct type of replacement radiant. Ask for Valor Fires part number 5132071 (Single Radiant). Turn the fire off and allow it to cool before attempting to remove the radiants. To remove the dress guard, gently pull the centre of the dress guard with one hand and carefully spring out one end of the dress guard with the other.
  • Page 40 OWNER GUIDE MAINTENANCE Battery replacement (Electronic ignition). 1. The battery cover is located at the base of the fire on the right hand side. 2. To access the battery cover the fascia will have to be removed. The fascia securing screws are located at the bottom rear of the fascia.
  • Page 41 OWNER GUIDE WARRANTY AND SERVICE Standard Warranty Terms & Conditions The warranty is for 12 months subject to contract. In the United Kingdom servicing can be carried out either by a heateam service engineer or a GAS SAFE REGISTER engineer. Outside of the United Kingdom servicing can be carried out either by a CORGI or GAS SAFE REGISTER engineer.
  • Page 42 OWNER GUIDE When calling heateam, it would be helpful if you could have the following information to hand:- Fire serial number and fascia code (The serial number can be found on the serial number label - See figure 7 on page 47).* Date of installation.* Your installer name and address details.* Fire make and model number.*...
  • Page 43 OWNER GUIDE © Baxi Heating U.K. Limited 2009. Page 43...
  • Page 44 OWNER GUIDE © Baxi Heating U.K. Limited 2009.
  • Page 45 OWNER GUIDE © Baxi Heating U.K. Limited 2009. Page 45...
  • Page 46 OWNER GUIDE To be completed by installer: Installer Details (Block Capitals) Installer Name Gas Safe Register or Corgi Registration Number. Company Name. Company Address Company Telephone number Company Fax number © Baxi Heating U.K. Limited 2009. Page 46...
  • Page 47: Owner Guide

    OWNER GUIDE Model Serial number (Can be found on the serial number label - See figure 7) A LABEL CONTAINING THE SERIAL NUMBER LABEL SERIAL NUMBER MAY HAVE TO BE AFFIXED HERE BEEN PLACED INSIDE THIS BOX. Fascia name (Block Capitals) Fascia code - Can be found close to the information label (Block Capitals) A LABEL CONTAINING THE FASCIA CODE...