free hit counter
Table of Contents

Advertisement

Kikko Max
English
Code:
Date:
P250U00
11 - 2005

Advertisement

Table of Contents
loading

Summary of Contents for Necta Kikko Max P250U00

  • Page 1 Kikko Max English Code: Date: P250U00 11 - 2005...
  • Page 2 Legend Necta’s vending machines can function in 3 different operating modes: - Normal vending mode - Normal vending mode - Normal vending mode - Normal vending mode - Normal vending mode - Filler menu - Filler menu - Filler menu...
  • Page 3 1 Statistics 1 STATISTICS 1.1 Printing the Statistics 1.1 STATISTICS PRINTING 1.1.1 Partial printout 1.1.1 Partial printing 1.1.1.1 Printing the selection counters 1.1.1.1 SELECT.COUNT. PRINT. When confirming this function, the counters regarding the different selections are printed. 1.1.1.2 PRINT BAND COUNTER 1.1.1.2 Printing the time band counters When confirming this function, the counters regarding the different time bands are printed.
  • Page 4: Table Of Contents

    1 STATISTICS 1.3 Displaying the statistics 1.3 STATISTICS DISPLAY 1.3.1 Displaying the selection counters 1.3.1 SELECT. COUNT. DISP. 1.3.1.1 Displaying the single counters 1.3.1.1 COUNT DISP. X S.SEL. This function is used for displaying the counters regarding each selection, divided by price band (0, 1, 2, 3, 4, Free, Test). 1.3.1.2 Displaying the total counters 1.3.1.2 TOTAL COUNT DISPLAY This function is used for displaying the total counters regard-...
  • Page 5 1 STATISTICS 1.4 Displaying the relative statistics 1.4 DISPLAY RELAT. STAT. 1.4.1 Displaying the selection counters 1.4.1 SELECT. COUNT. DISP. 1.4.1.1 Displaying the single counters 1.4.1.1 COUNT DISP. X S.SEL. This function is used for displaying the counters regarding each selection, divided by price band (0, 1, 2, 3, 4, Free, Test). 1.4.1.2 Displaying the total counters 1.4.1.2 TOTAL COUNT DISPLAY This function is used for displaying the total counters regard-...
  • Page 6 1 STATISTICS 1.5 DELETE RELAT. STAT. 1.5 Deleting the relative statistics 1.5.1 Partial delete 1.5.1 PARTIAL RESET 1.5.1.1 Deleting the selection counters 1.5.1.1 SELECT. COUNT. RESET When confirming this function, the counters regarding the different selections, described at point 3.4.1, are deleted. 1.5.1.2 DISCOUNT COUNT.RESET 1.5.1.2 Deleting the discount counters When confirming this function, the counters regarding dis-...
  • Page 7: Boiler Temperature

    2 Setting single prices 2 SET INDIVIDUAL PRICE Four different prices can be set for each selection according to the programmed time bands, if enabled. 2.1 Price band 0 2.1 PRICE BAND 0 This function is used for setting the prices of each selection for time band 0 (if enabled).
  • Page 8 5 Test 5 Test 5.1 Complete dispensing 5.1 COMPLETE DISPENSING With this function it is possible to obtain, with the door open and without inserting any money, complete dispensing for each selection. 5.2 Dispensing water only 5.2 WATER ONLY With this function it is possible to dispense, with the door open and without inserting any money, only the water doses for each selection.
  • Page 9 1. FAILURES 1. Failures 1.1 Reading the failures 1.1 FAILURE READING When the “Failure” function is displayed, press the confirm but- ton “ ” to display the present failures. If no failures are currently present, after pressing the confirm button “ ” the message “End failures” will be displayed. The possible failures are indicated in the following cases: Water failure Water failure...
  • Page 10 1. FAILURES RAM Data RAM Data RAM Data RAM Data RAM Data RAM data One or more areas of the RAM contain wrong data which was corrected with the default values. The machine will continue to function, but it would be advisable to initialise as soon as possible.
  • Page 11 2 Setting the parameters 2. SET PARAMETERS 2.1 Cash 2.1 cash This set of functions controls all parameters regarding the pay- ment systems and the sales prices. 2.1.1 Prices 2.1.1 PRICES Four different prices can be set for each selection according to the programmed time bands for when the time table option is enabled.
  • Page 12 2. SET PARAMETERS 2.1.2 Coin mechanisms 2.1.2 COIN MECHANISM 2.1.2.1 Setting the coin mechanisms 2.1.2.1 COIN MECHANISM SET. It is possible to decide which of the payment system protocols available are to be enabled for the functions. The available payment systems are: - Executive - Validators - BDV...
  • Page 13 2. SET PARAMETERS Accepted coins Accepted coins Accepted coins Accepted coins Accepted coins 2.1.2.1 COIN MECHANISM SET. It is possible to define which, among the coins recognised by the validator, are to be accepted. Check the label on the coin mechanism for the correct coin to value matching, indicating the position of the coins.
  • Page 14 2. SET PARAMETERS 2.1.2.1 COIN MECHANISM SET. M D B M D B M D B M D B M D B The MDB protocol menus are used for defining the following functions: Type of vending Type of vending Type of vending Type of vending Type of vending Setting the operating mode for multiple or single dispensing.
  • Page 15 2. SET PARAMETERS Accepted coins with “exact amount” Accepted coins with “exact amount” Accepted coins with “exact amount” Accepted coins with “exact amount” Accepted coins with “exact amount” It is possible to define which, among the coins recognised by the validator, are to be accepted when the machine is in the “exact amount”...
  • Page 16 2. SET PARAMETERS 2.1.4 Master slave 2.1.4 Master / Slave 2.1.4.1 Settings 2.1.4.1 SETTING The machine control system is pre-arranged for the connection in a bank of vending machines using special kits. This permits the use of a single payment system for more ma- chines.
  • Page 17 2. SET PARAMETERS 2.1.4.4 Reset Snakky SL 2.1.4.4 reset snakky sl This function is used for resetting the programming of a Snakky SL to default values. 2.1.4.5 Monitor Slave 2.1.4.5 monitor slave This function is used for scrolling through all the information of a slave being connected.
  • Page 18 2. SET PARAMETERS 2.2 SELECTIONS 2.2 Selections 2.2.1 Setting the water 2.2.1 SET WATER 2.2.1.1 Water doses 2.2.1.1 WATER DOSES This function is used for setting the water dose, expressed in cc, for each selection button and therefore for each product as- signed to it;...
  • Page 19 2. SET PARAMETERS 2.2.2 Setting the powders 2.2.2 SET POWDER 2.2.2.1 Powder doses 2.2.2.1 POWDER DOSES The powder dose, expressed in grams, can be set for each selec- tion button and therefore each product assigned to it; the dis- play indicates the name of the product being selected. 2.2.2.2 Setting the doser units 2.2.2.2 DOSER SETTING This function is used for setting the flow rate of the single...
  • Page 20 2. SET PARAMETERS 2.3 Machine parameters 2.3 MACHINE PARAM. 2.3.1 Boiler temperature 2.3.1 BOILER TEMPERAT. This function is used for setting the operating temperature, ex- pressed in °C, of the boiler installed in the machine. When pressing the confirm button “ ” the temperature value starts blinking and can be modified.
  • Page 21 2. SET PARAMETERS 2.3.8 Dispensing compartment lamp timing 2.3.8 SLIDER LAMP TIME In the event the machine is equipped with a dispensing compart- ment lamp. With this function it is possible to define how long (programmable between 0 and 300 t/s, 70 by default) the light- ing lamp inside the dispensing compartment is to stay on, if the cup sensor is not fitted.
  • Page 22 2. SET PARAMETERS 2.4 Display 2.4 display 2.4.1 Language 2.4.1 LANGUAGE It is possible to choose which of the following languages, avail- able in the software, is to be used for the messages on the dis- play: - Italian - French - Spanish - English - German...
  • Page 23 2. SET PARAMETERS 2.5 Pre-selections 2.5 PRE-SELECTIONS This function is used for setting the pre-selections present in this model, enabling or disabling the pre-selection for a certain selec- tion, changing dose and price. An example for the first pre-selection is indicated below; the operations to be carried out are identical for each selection.
  • Page 24: Setting The Password

    2. SET PARAMETERS 2.6 Miscellaneous 2.6 MISCELLANEOUS 2.6.1 Jug facilities 2.6.1 jug facilities Models that have this function and are equipped with a special key, it is possible to obtain a programmable number of selections (1 to 9; 5 by default) without cup to fill a jug. 2.6.2 Password This function is used for setting a password for accessing the 2.6.2 password...
  • Page 25 2. SET PARAMETERS 2.6 MISCELLANEOUS 2.6.6 Espresso unit 2.6.6 es unit This function is used for setting the vending machine to the 2 possible types of espresso unit: Z2000 or Z3000 according to which one is installed in the machine. 2.6.7 Automatic unit wash 2.6.7 auto.
  • Page 26: Displaying The Statistics

    3 Statistics 3. STATISTICS 3.1 Electronic counter 3.1 ELECTRONIC COUNTER 3.1.1 Displaying the selection counters 3.1.1 DISPLAY COUNTERS This function is used for displaying the total number of selec- tions dispensed by the vending machine. 3.1.2 Resetting the counters at power-on 3.1.2 RESET COUNTER This function is used for resetting the general selection counter.
  • Page 27 3. STATISTICS 3.2.5 Displaying the coin mechanism data 3.2.5 COIN MECH.DATA DISP. 3.2.5.1 Displaying the audit data 3.2.5.1 AUDIT DATA DISPLAY This function is used for displaying the number of coins inserted in the vending machine, differentiated by the type of coin. 3.2.5.2 Displaying the cashed amount 3.2.5.2 CASH COUNT.
  • Page 28 3. STATISTICS 3.4 Displaying the relative statistics 3.4 DISPLAY RELAT. STAT. 3.4.1 Displaying the selection counters 3.4.1 SELECT. COUNT. DISP. 3.4.1.1 Displaying the single counters 3.4.1.1 COUNT DISP. X S.SEL. This function is used for displaying the counters regarding each selection, divided by price band (0, 1, 2, 3, 4, Free, Test).
  • Page 29 3. STATISTICS 3.5 DELETE RELAT. STAT. 3.5 Deleting the relative statistics 3.5.1 Partial delete 3.5.1 PARTIAL RESET 3.5.1.1 Deleting the selection counters 3.5.1.1 SELECT. COUNT. RESET When confirming this function, the counters regarding the dif- ferent selections, described at point 3.4.1, are deleted. 3.5.1.2 DISCOUNT COUNT.RESET 3.5.1.2 Deleting the discount counters When confirming this function, the counters regarding discounts...
  • Page 30 3. STATISTICS 3.7.2 Total printout 3.7.2 TOTAL PRINTING When confirming this function, all statistics are printed. 3.8 Printing the relative statistics 3.8 PRINT RELAT. STAT. 3.8.1 Partial printout 3.8. 1 Partial printing 3.8.1.1 Printing the selection counters 3.8.1.1 SELECT.COUNT. PRINT. When confirming this function, the relative counters regarding the different selections are printed.
  • Page 31 4. Test 4. test 4.1 Test dispensing 4.1 TEST DISPENSING 4.1.1 Complete dispensing 4.1.1 COMPLETE DISPENSING With this function it is possible to obtain, with the door open and without inserting any money, complete dispensing for each selection. 4.1.2 WATER ONLY 4.1.2 Dispensing water only With this function it is possible to dispense, with the door open and without inserting any money, only the water doses for each...
  • Page 32 4. test 4.3 Autotest 4.3 autotest This function allows testing, in a semiautomatic way, of the main machine components. When pressing the confirm button, the message “AUTOTEST” will be start blinking. It is possible to cancel each operation and go to the next one by pressing the exit button, but confirming with the confirm button to start the autotest routine.
  • Page 33 5 Miscellaneous 5 varie 5.1 Vending machine information 5.1 D.A. REGISTRY 5.1.1 Installation date 5.1.1 INSTALLATION DATE This function is used for storing the current date of system as installation date of the vending machine. This date will be indi- cated on the statistics printout.
  • Page 34 5 varie 5.3 EVADTS 5.3 evadts The EVADTS (European Vending Association Data Transfer Sys- tem) communication protocol has 2 codes for identifying the machine and for recognising the data transfer terminal. 5.3.1 Pass code 5.3.1 pass code It is a four-digit alphanumeric code (0-9; A-F) that must be the same as the one in the data transfer terminal to allow its identi- fication.
  • Page 35 5 varie 5.4 Up-key 5.4 upkey 5.4.1 Setup control 5.4.1 SETUP MANAGEMENT 5.4.1.1 Up-Key -> vending machine 5.4.1.1 UPKEY -> MACHINE When confirming this function after inserting the Up-Key in the special port located on the C.P.U. board, it will be possible to select the setup file from the list shown on the display using the scrolling buttons, then when confirming with the confirm button the selected setup will be loaded in the vending machine.
  • Page 36 6 GSM 6 gsm The control software can send, via GSM modem, a signal indicat- ing a machine failure or an “ending product” “pre-alarm”, after dispensing a certain (programmable) number of selections of a given product. 6.1 gsm pin code 6.1 GSM Pin code This function is used for programming the identification code that will be sent to the GSM modem (optional) when switching...

Table of Contents

Save PDF