Lit. No. 94-30-007A
There are 2 relay boards, 1 for a single oven and 1 for a double oven. You can use the
double oven board for a single oven. You must use a double oven board for a double oven.
The relay board has 14 snap relays activated by 24 volts d.c., 8 small pin headers that carry
signal voltage to components, and 5 large pin headers that provide or transfer 120 volts ac
to components.
Relays K0 through K15:
K0
Transfers 12 volts from transformer to microwave board.
K1
Transfers 120 volts from L2 to lower oven latch motor.
K2
None
K3
None
K4
Transfers 120volts from L2to both oven cooling motors.
K5
Transfers 120 volts from L2 to both oven cooling motors.
K6
Transfers current to complete 12 v.a.c. Upper oven halogen light circuit.
K7
Transfers current to complete 12 v.a.c. Lower oven halogen light circuit.
K8
Transfers 120 volts from L2 to upper oven Jet Blowers (both).
K9
Transfers 120 volts from L2 to upper oven convection elements.
K10
Transfers 120 volts from L2 to upper oven Jet Plate and mullion elements.
K11
Transfers 120 volts from L2 to upper oven tube fan and stirrer motor.
K12
Transfers 120 volts from L2 to lower oven bake element
K13
Transfers 120 volts from L2 to lower oven broil element.
K14
Transfers 120 volts from L2 to lower oven convection element.
K15
Transfers 120 volts from L2 to lower oven convection motor.
These relays have normally open contacts that transfer voltage when the are snapped
closed. These relays have a coil that is snapped closed by 24 VDC from the eeprom
(memory chip) on the relay board.
"CJ" DAC RELAY BOARD
(Digital Appliance Controls)
Page 75
CJ Oven Service Manual