Changing a Bank of Heating Elements (Continued).
Remove the four hex head screws which secure the bank to the housing and remove
the bank of elements.
The interior surface where the bank of elements were previously attached should be
cleaned completely of any remaining sealant.
A new bank of elements must be sealed to the housing using a NSF/FDA approved
silicone sealant.
Finish installing the new elements by reversing the above disassembly procedures.
Replacing the Exterior Door Gasket
Remove the 18 screws which hold the gasket retainers on.
Remove the gasket.
The sheet metal surface of the door where the gasket was attached and the retainers
should be cleaned completely of any remaining sealant.
Replace the gasket retainers but leave the screws loose.
Start replacing the gasket on the hinge side of the door beginning about 1-1/2" above
the spot where the two retainers meet. Slide the gasket between the retainer and
the door surface making sure it is seated completely especially in the corners.
Tighten the gasket retainer screws as you go.
Completely seal the inside and outside edges of the gasket using a NSF/FDA
approved silicone sealant. (Run a bead underneath the outside edge of the gasket
as well as along the edge
Allow sealant to dry before closing the door or operating the oven, (approximately
four to five hours).
Replacing the Interior Door Gasket
Remove the 14 screws securing the door panel (It has the exterior gasket fastened
to it).
Lay the panel down and remove the gasket from the glass and metal frame.