Page 1
240 (T-H3J), 340 (T-H3S) and 540 (T-H3) Models On-Demand Water Heater Service Manual A.O. Smith Water Products Company 500 Tennessee Waltz Parkway Ashland City, TN 37015 Toll Free: 1-877-737-2840...
CONFIDENTIAL 240 (T-H3J), 340 (T-H3S) and 540 (T-H3) models Service Manial Ver. 1.00 Table of Contents 1. Specifications........................ 2. Exterior view........................ 3. Interior view........................ 4. List of main components in the interior view..............5. Schematic diagram......................6.
240 (T-H3J), 340 (T-H3S) and 540 (T-H3) models Service Manial Ver. 1.00 1. Specifications Model Indoor Outdoor Indoor Outdoor Indoor Outdoor (T-H3J-DV) (T-H3J-OS) (T-H3S-DV) (T-H3S-OS) (T-H3-DV) (T-H3-OS) inch H 22.4 x W 17.7 x D 10.7 Dimensions 570 (H) x 450 (W) x 272 (D) Weight lbs.
CONFIDENTIAL 240 (T-H3J), 340 (T-H3S) and 540 (T-H3) models Service Manial Ver. 1.00 4. List of main components in the interior view Items# in Part # Description components 240, 340 and T-H3J, T-H3S and diagram 540 models T-H3 models Indoor EK159 models Case assembly...
Page 11
CONFIDENTIAL 240 (T-H3J), 340 (T-H3S) and 540 (T-H3) models Service Manial Ver. 1.00 Items# in Part # Description components 240, 340 and T-H3J, T-H3S and diagram 540 models T-H3 models Indoor 319143-443 EK109 models Fan motor Outdoor 319143-043 EKK25 models Indoor Freeze 319143-496...
Page 12
CONFIDENTIAL 240 (T-H3J), 340 (T-H3S) and 540 (T-H3) models Service Manial Ver. 1.00 Items# in Part # Description components 240, 340 and T-H3J, T-H3S and diagram 540 models T-H3 models Manifold port Gas inlet port 319143-525 EK198 Indoor (240/340 models) (T-H3J/T-H3S models) 319143-527 models...
CONFIDENTIAL 240 (T-H3J), 340 (T-H3S) and 540 (T-H3) models Service Manial Ver. 1.00 5. Schematic diagram The diagram below refers to both the Direct Vent Indoor models and Outdoor models. Direct Vent Indoor models only Hi-limit switch for exhaust Intake port Exhaust Exhaust thermistor Secondary heat exchanger...
CONFIDENTIAL 240 (T-H3J), 340 (T-H3S) and 540 (T-H3) models Service Manial Ver. 1.00 6. Wiring diagram 240 (T-H3J) models / 340 (T-H3S) models W: WHITE BK: BLACK LB: LIGHT BLUE R: RED BL: BLUE Y: YELLOW G: GREEN O: ORANGE BR: BROWN P: PURPLE 240/340 Outdoor...
Page 15
CONFIDENTIAL 240 (T-H3J), 340 (T-H3S) and 540 (T-H3) models Service Manial Ver. 1.00 540 (T-H3) models W: WHITE BK: BLACK LB: LIGHT BLUE R: RED BL: BLUE Y: YELLOW G: GREEN O: ORANGE BR: BROWN P: PURPLE 540 Outdoor 540 Direct Vent Indoor Heater Heater Heater...
CONFIDENTIAL 240 (T-H3J), 340 (T-H3S) and 540 (T-H3) models Service Manial Ver. 1.00 7. Wiring diagram check points for diagnosis The table below applies to both the the Direct Vent Indoor models and Outdoor models. Check- Part and Description Color of wires Normal range point 120V Power supply...
Page 17
CONFIDENTIAL 240 (T-H3J), 340 (T-H3S) and 540 (T-H3) models Service Manial Ver. 1.00 Check- Part and Description Color of wires Normal range point Remote controller White – Black 11 to 25 VDC Red - Blue 132 to 192 VDC Fan motor Yellow - Blue 13 to 17 VDC Orange - Blue...
CONFIDENTIAL 240 (T-H3J), 340 (T-H3S) and 540 (T-H3) models Service Manial Ver. 1.00 8. (A) Resistance values of the temperature thermistors The the Direct Vent Indoor models and Outdoor models use the same thermistors. Resisitance values at different temperatures °F Temperature °C Resistance...
CONFIDENTIAL 240 (T-H3J), 340 (T-H3S) and 540 (T-H3) models Service Manial Ver. 1.00 8. (B) Resistance values of the temperature exhaust thermistor Only the Direct Vent Indoor models are equipped with the exhaust thermistor. Resisitance values at different temperatures °F Temperature °C Resistance...
CONFIDENTIAL 240 (T-H3J), 340 (T-H3S) and 540 (T-H3) models Service Manial Ver. 1.00 9. Operational flow chart The diagram below refers to both the Direct Vent Indoor models and Outdoor models. Power supply ON FAV&BV open Operation SW ON Remove cause Opeartion lamp OFF Operation stop Pre-check...
CONFIDENTIAL 240 (T-H3J), 340 (T-H3S) and 540 (T-H3) models Service Manial Ver. 1.00 10-1. Burners Part # • 319143-514 (EK192) Unit Part# #101 There are 2 types of burners in the burner assembly: the gas-rich burner stabilizes the flames within the combustion chamber and the air-rich burner produces more heat in the combustion chamber.
CONFIDENTIAL 240 (T-H3J), 340 (T-H3S) and 540 (T-H3) models Service Manial Ver. 1.00 10-2. Gas manifold • 319143-515 (EK181) : Propane Included Part # Unit Part# • 319143-516 (EK182) : Natural gas in #102 1. The manifold distributes gas from the gas valves to the burners. The manifold has two types of the nozzles: one type for gas-rich burners (16 nozzles) and the other for air-rich burners (15 nozzles) Function...
CONFIDENTIAL 240 (T-H3J), 340 (T-H3S) and 540 (T-H3) models Service Manial Ver. 1.00 10-3. Fan motor • 319143-443 (EK109) : Direct Vent Indoor model Part # Unit Part# #103 • 319143-043 (EKK25) : Outdoor model To provide combustion air into the combustion chamber and to exhaust Function flue gas.
CONFIDENTIAL 240 (T-H3J), 340 (T-H3S) and 540 (T-H3) models Service Manial Ver. 1.00 10-4. Gas valve assembly • 319143-515 (EK181) : Propane Included in Part# Unit Part# • 319143-516 (EK182) : Natural gas #102 Opens and closes the gas pathways of the water heater (main and solenoid gas valves) Function Modulates the gas flow from the gas inlet (proportional gas valve)
CONFIDENTIAL 240 (T-H3J), 340 (T-H3S) and 540 (T-H3) models Service Manial Ver. 1.00 10-5. Flame rod Part # • 319143-517 (EK193) Unit Part# #108 Function To detect flames while the water heater is in operation. 1. Unable to detect flames when flames actually do occur. Failure events 2.
CONFIDENTIAL 240 (T-H3J), 340 (T-H3S) and 540 (T-H3) models Service Manial Ver. 1.00 10-6. AFR rod Part # • 319143-517 (EK193) Unit Part# #108 Checks flame conditions during combustion. Function When AFR rod detects unexpected flame conditions, the computer of the water heater makes adjustments in the fan motor speed to compensate.
Color / Number of wires Checkpoint NOTE: Pictures are on the following page Part # Model 319143-525 EK198 240 Indoor (T-H3J-DV) / 340 (T-H3S-DV) 319143-526 EK199 240 Outdoor (T-H3J-OS) / 340 (T-H3S-OS) 319143-527 EK200 540 Indoor (T-H3-DV) 319143-528...
Page 29
CONFIDENTIAL 240 (T-H3J), 340 (T-H3S) and 540 (T-H3) models Service Manial Ver. 1.00 10-7. Heat exchanger The heat exchanger of the 240 (T-H3J) and 340 (T-H3S) models have the “77” mark, and 540 (T-H3) models have the "P77" mark as shown below. 240, 340 Indoor (T-H3J, T-H3S-DV) 240, 340 Outdoor (T-H3J, T-H3S-OS) 11"...
Inspect for soot buildup inside the secondary heat exchanger. Color / Number of wires Checkpoint NOTE: Pictures are on the following page Part # Model 319143-525 EK198 240 Indoor (T-H3J-DV) / 340 (T-H3S-DV) 319143-526 EK199 240 Outdoor (T-H3J-OS) / 340 (T-H3S-OS) 319143-527 EK200 540 Indoor (T-H3-DV) 319143-528...
Page 31
CONFIDENTIAL 240 (T-H3J), 340 (T-H3S) and 540 (T-H3) models Service Manial Ver. 1.00 10-8. Secondary heat exchanger The heat exchanger of the 240 (T-H3J) and 340 (T-H3S) models have the “77” mark, and 540 (T-H3) models have the "P77" mark as shown below. 240, 340 Indoor (T-H3J, T-H3S-DV) 240, 340 Outdoor (T-H3J, T-H3S-OS) 11"...
CONFIDENTIAL 240 (T-H3J), 340 (T-H3S) and 540 (T-H3) models Service Manial Ver. 1.00 10-9. Flow adjustment valve Part# • 319143-463 (EK129) Unit Part# #402 Function Controls water flow to properly control the output hot water temperature. 1. Water leakage from valve. Failure events 2.
CONFIDENTIAL 240 (T-H3J), 340 (T-H3S) and 540 (T-H3) models Service Manial Ver. 1.00 10-10. Flow sensor Part# • 319143-463 (EK129) Unit Part# #402 Detects and measures water flow rate using a spinning impeller and Function magnetic pick-up. Failure events Unable to detect or measure any water flow rate. Ignition sequence does not start (water heater will not initiate any Effects on the water heater operation)
CONFIDENTIAL 240 (T-H3J), 340 (T-H3S) and 540 (T-H3) models Service Manial Ver. 1.00 10-11. Bypass valve (540 (T-H3) models only) • 319143-464 (EKD58) Part # Unit Part# #403 540 (T-H3) models only 1. Mixes hot water from the heat exchanger with cold water from the water inlet in order to modulate and control the water heater’s outlet water temperature.
CONFIDENTIAL 240 (T-H3J), 340 (T-H3S) and 540 (T-H3) models Service Manial Ver. 1.00 10-12. Thermistors #407 (Inlet) Unit Part # *See the table below #408 (Outlet ) Part# #411 (Heat exchanger) Function Measures cold/hot water temperatures in the water heater. Failure events Unable to properly measure water temperatures within the water heater.
Page 36
CONFIDENTIAL 240 (T-H3J), 340 (T-H3S) and 540 (T-H3) models Service Manial Ver. 1.00 10-12. Thermistors 240 (T-H3J) and 340 (T-H3S) models Part# 319143-214 (EKK4J) (Inlet thermistor) 42 Part# 319143-529 (EK207) (Outlet thermistor) 113 540 (T-H3) models Black Part# 319143-465 (EK137) (Inlet thermistor) 42 Blue Part# 319143-190 (EKK1A)
CONFIDENTIAL 240 (T-H3J), 340 (T-H3S) and 540 (T-H3) models Service Manial Ver. 1.00 10-13. Exhaust thermistor Part# • 319143-131 (EKH6E) Unit Part# #718 Function Measures the exhaust temperatures in the secondary heat exchanger. Failure events Unable to measure exhaust temperature in the exhaust chamber properly. If the thermistors fail open or short, error code appears before starting Effects on the water heater operation.
CONFIDENTIAL 240 (T-H3J), 340 (T-H3S) and 540 (T-H3) models Service Manial Ver. 1.00 10-14. Hi-limit switch • 319143-228 (EM212) 240 (T-H3J) /340 (T-H3S) models Part# Unit Part# #412 • 319143-095 (EKN34) 540 (T-H3) models -Based on bi-metal thermal expansion. -Detects excessively high water temperature in pipes of the heat exchanger. -After detection, communication between the computer board and gas Function valves are severed, shutting down the water heater instantly.
Page 39
CONFIDENTIAL 240 (T-H3J), 340 (T-H3S) and 540 (T-H3) models Service Manial Ver. 1.00 10-14. Hi-limit switch After the hi-limit switch was working, refer to the following procedure. 1. Turn off the controller. 2. Open a hot water tap and lower the temperature of the heat exchanger. 3.
CONFIDENTIAL 240 (T-H3J), 340 (T-H3S) and 540 (T-H3) models Service Manial Ver. 1.00 10-15. Hi-limit switch for exhaust Part# • 319143-104 (EKH6G) Unit Part# #472 -Based on bi-metal thermal expansion. -Detects excess temperature (more than 151˚F or 66˚C) of exhaust gas in Function the exhaust chamber.
CONFIDENTIAL 240 (T-H3J), 340 (T-H3S) and 540 (T-H3) models Service Manial Ver. 1.00 10-16. Overheat cut off fuse Part# • 319143-149 (EK333) Unit Part# #413 -The overheat cutoff fuse contains solder with a melting point of 430 ˚F (221 ˚C). -Detects excessive temperatures within the water heater, especially around the heat exchanger and combustion chamber.
CONFIDENTIAL 240 (T-H3J), 340 (T-H3S) and 540 (T-H3) models Service Manial Ver. 1.00 10-18. Computer board • 319143-543 (EK186): 240 (T-H3J) models Part# • 319143-544 (EK175): 340 (T-H3S) models Unit Part# #701 • 319143-545 (EK176): 540 (T-H3) models Function Controls the functions of most of the parts in the water heater. Failure events Malfunctioning computer -A component(s) may not operate within the water heater.
CONFIDENTIAL 240 (T-H3J), 340 (T-H3S) and 540 (T-H3) models Service Manial Ver. 1.00 10-19. Igniter Part # • 319143-479 (EK153) Unit Part# #711 -To ignite the gas/air mixtures when the water heater is ready to burn gas on its burner surface. Function -The output voltage of the igniter is more than 14 kVDC.
CONFIDENTIAL 240 (T-H3J), 340 (T-H3S) and 540 (T-H3) models Service Manial Ver. 1.00 10-20. Freeze protection thermostat • 319143-496 (EK184): Indoor Part# Unit Part# #713 • 319143-497 (EK185): Outdoor Temperature detecting device which prevents the pipes within the water heater from freezing. When this device detects temperatures below 36.5 ˚F Function (2.5 ˚C) inside the water r heater, power is supplied to the electric heaters to prevent the water heater from freezing.
CONFIDENTIAL 240 (T-H3J), 340 (T-H3S) and 540 (T-H3) models Service Manial Ver. 1.00 10-21. Surge box Part# Unit Part# #121 • 319143-522 (EK163) Protects the unit from high voltage and/or high electric current caused by lightning. There are 2 types of surge absorbers in the water heater. Surge absorber Function A is activated by voltage higher than 220 V, the other one is activated by voltage higher than 680 V.
CONFIDENTIAL 240 (T-H3J), 340 (T-H3S) and 540 (T-H3) models Service Manial Ver. 1.00 11. Fault Analysis & Specifications Remarks: 1. Proper range of values of voltage & resistance shown below. 2. Please refer to the wiring diagram for checkpoint positions. 3.
Page 48
CONFIDENTIAL 240 (T-H3J), 340 (T-H3S) and 540 (T-H3) models Service Manial Ver. 1.00 Check Natural of Fault Diagnosis point 1 Check whether the flow rate is high enough to keep the water heater running. 2 Check if there is a recirculation system installed and check also if the •...
Page 49
CONFIDENTIAL 240 (T-H3J), 340 (T-H3S) and 540 (T-H3) models Service Manial Ver. 1.00 Check Natural of Fault Diagnosis point 6 Fault of PCB in the water heater No voltage flow adjustment valve • Fluctuation of hot Normal: 7.0 to 16 VDC between (red-black) water temperature 7 Flow adjustment valve fault Normal: 0.09 to 0.2 kΩ...
Page 50
CONFIDENTIAL 240 (T-H3J), 340 (T-H3S) and 540 (T-H3) models Service Manial Ver. 1.00 Error Code Malfunction description Cancellation method Ignition failure Turn off the power or water supply Diagnosis Check point 1 Check gas supply and inlet gas pressure (Refer to section 1) 2 Check the igniter (Refer to section 10-19) Visual inspection: connection/breakage of wires and/or observed weak spark.
Page 51
CONFIDENTIAL 240 (T-H3J), 340 (T-H3S) and 540 (T-H3) models Service Manial Ver. 1.00 Error Code Malfunction description Cancellation method Loss of flame Turn off the power or water supply Diagnosis Check point 1 Check gas supply and pressure (Refer to section 1) 2 PCB fault [1] No voltage to gas main solenoid valve (MV) Normal: 93 to 120 VDC between COM (blue) &...
Page 52
CONFIDENTIAL 240 (T-H3J), 340 (T-H3S) and 540 (T-H3) models Service Manial Ver. 1.00 Error Code Malfunction description Cancellation method Disconnected/short-circuited inlet thermistor Turn off the power or water supply Diagnosis Check point 1 Inlet thermistor fault (Refer to section 10-12) Visual inspection: connection/breakage of wires and/or debris on thermistor.
Page 53
CONFIDENTIAL 240 (T-H3J), 340 (T-H3S) and 540 (T-H3) models Service Manial Ver. 1.00 Error Code Malfunction description Cancellation method Flow sensor failure (Only Easy-link system) Turn off the power or water supply Diagnosis Check point 1 Flow sensor fault (Refer to section 10-10) Visual inspection: connection/breakage of wires and/or debris on impeller.
Page 54
CONFIDENTIAL 240 (T-H3J), 340 (T-H3S) and 540 (T-H3) models Service Manial Ver. 1.00 Error Code Malfunction description Cancellation method Fan motor fault Turn off the power or water supply Diagnosis Check point 1 PCB and fan motor fault (Refer to section 10-3 & 10-18) Visual inspection of fan motor: connection/breakage of wires or dust buildup (causing electrical shortage) Normal: 132 to 192 VDC between red &...
Page 55
CONFIDENTIAL 240 (T-H3J), 340 (T-H3S) and 540 (T-H3) models Service Manial Ver. 1.00 Error Code Malfunction description Cancellation method 1 PCB fault (701 error code) [1] Fault of preparation for the outlet thermistor Turn off the power or water supply operation.
Page 56
CONFIDENTIAL 240 (T-H3J), 340 (T-H3S) and 540 (T-H3) models Service Manial Ver. 1.00 Error Code Malfunction description Cancellation method Miscommunication between water heater and When computer detects temperature controller (Direct Vent Indoor proper connections between the models only) water heater and the temperature controller, "751"...
Page 57
CONFIDENTIAL 240 (T-H3J), 340 (T-H3S) and 540 (T-H3) models Service Manial Ver. 1.00 Error Code Malfunction description Cancellation method Abnormal exhaust temperature Turn off the power or water supply (Direct Vent Indoor models only) Diagnosis Check point 1 Check how long the water heater has been installed and in use. 2 Check the vent length.
CONFIDENTIAL 240 (T-H3J), 340 (T-H3S) and 540 (T-H3) models Service Manial Ver. 1.00 12. Controls and settings 12-1. Diagnosis using the temperature controller and temperature remote controller..59 12-2. Verifying functionality of computer board..............63 12-3. Displaying error code history, Clearing error code history memory, and Display patterns for error codes....................64 12-4.
CONFIDENTIAL 240 (T-H3J), 340 (T-H3S) and 540 (T-H3) models Service Manial Ver. 1.00 12-1. Diagnosis using the temperature controller and temperature remote controller TEMPERATURE CONTROLLER and TEMPERATU REREMOTE CONTROLLER The illustration below shows an example of the controllers. The exact display may differ from examples. Temperature controller Temperature remote controller Display for Temperature...
Page 60
CONFIDENTIAL 240 (T-H3J), 340 (T-H3S) and 540 (T-H3) models Service Manial Ver. 1.00 < For multiple units in an Easy-Link system > 1. Press and hold the "HOT" and "COLD" buttons simultaneously for at least 5 seconds to enter “Diagnostics Mode”.
Page 61
CONFIDENTIAL 240 (T-H3J), 340 (T-H3S) and 540 (T-H3) models Service Manial Ver. 1.00 Description of mode numbers in “Diagnostics Mode” Mode # Whole multi-unit system information (#0) Unit information (#1 to #4) Total system flow rate 0 to 999 (GPM) Total operation time 0 to 999 (x 100 hours) BTU requirement for...
Page 62
CONFIDENTIAL 240 (T-H3J), 340 (T-H3S) and 540 (T-H3) models Service Manial Ver. 1.00 Mode # Whole multi-unit system information (#0) Unit information (#1 to #4) Bypass valve 0 to 999 (x 10 steps) position** closed position = 0 Ratio of hot water and 0 to 999 (%) cold water** EEPROM Initialization...
CONFIDENTIAL 240 (T-H3J), 340 (T-H3S) and 540 (T-H3) models Service Manial Ver. 1.00 12-2. Verifying functionality of computer board A. How to check if the computer board works properly Check the power ON-OFF switch of the water heater. AC120V The factory setting is ON position. Power ON-OFF switch Temperature remote controller...
CONFIDENTIAL 240 (T-H3J), 340 (T-H3S) and 540 (T-H3) models Service Manial Ver. 1.00 12-3. Displaying error code history, Clearing error code history memory and Display patterns for error codes Displaying error code history Check the mode #11 to 13 of "Diagnostic Mode" of the controller.
CONFIDENTIAL 240 (T-H3J), 340 (T-H3S) and 540 (T-H3) models Service Manial Ver. 1.00 12-4. Clearing the “101” and “991” error code The “101” and “991” error codes signify imperfect (abnormal) combustion, caused by insufficient intake air and/or obstructions in the exhaust. A.
CONFIDENTIAL 240 (T-H3J), 340 (T-H3S) and 540 (T-H3) models Service Manial Ver. 1.00 12-5. AFR rod function <Function> The AFR rod checks flame conditions during combustion. When the AFR rod detects unexpected flame conditions, the computer board of the water heater adjusts the fan motor speed to ensure that air and fuel are always at a proper mixture ratio, minimizing emissions.
CONFIDENTIAL 240 (T-H3J), 340 (T-H3S) and 540 (T-H3) models Service Manial Ver. 1.00 12-6. DIPswitch settings 240 (T-H3J) and 340 (T-H3S) models The 240 (T-H3J) /340 (T-H3S) Indoor shares the computer Computer board board with the 240 (T-H3J) /340 (T-H3S) Outdoor. The DIPswitches have certain special functions as shown on the following table and generally should not need adjustment.
Page 68
CONFIDENTIAL 240 (T-H3J), 340 (T-H3S) and 540 (T-H3) models Service Manial Ver. 1.00 The 540 Indoor (T-H3-DV) shares the computer board with the 540 Outdoor 540 (T-H3) models (T-H3-OS). There are two banks of DIPswitches computer board Upper bank of (upper and lower bank) on the computer board.
Page 69
CONFIDENTIAL 240 (T-H3J), 340 (T-H3S) and 540 (T-H3) models Service Manial Ver. 1.00 The lower bank of DIPswitches Functions ON position OFF position Parent/Child setting for Easy-Link systems Parent Child (Default) FM+, FM- and Input- (FM speed is increased automatically. See section 12-13) DEFAULT ON 1 2 3 4 5 6 No.2: OFF...
CONFIDENTIAL 240 (T-H3J), 340 (T-H3S) and 540 (T-H3) models Service Manial Ver. 1.00 12-7. Assigning unit numbers in the Easy-link system Only 540 (T-H3) models 540 (T-H3) models computer board A. How to display the unit number Press the “Increase” button on the computer board of child unit.
CONFIDENTIAL 240 (T-H3J), 340 (T-H3S) and 540 (T-H3) models Service Manial Ver. 1.00 12-8. (A) ON/OFF conditions: Overview The following table shows the ON/OFF conditions of the water heater. ON / OFF Conditions The BTU requirement is more than 29,800 BTU/h Inlet water temperature is lower 5.4 °F than the set temperature and BTU requirement is more than 14,880 BTU/h Conditions needed...
CONFIDENTIAL 240 (T-H3J), 340 (T-H3S) and 540 (T-H3) models Service Manial Ver. 1.00 12-8. (B) ON/OFF conditions: BTU requirements A. Calculating the ON/OFF conditions of the water heater "Condition needed to turn the water heater ON" – T ) × GPM × 500 > 14,880 "Condition needed to turn the water heater OFF"...
CONFIDENTIAL 240 (T-H3J), 340 (T-H3S) and 540 (T-H3) models Service Manial Ver. 1.00 12-9. Multi-unit system ON/OFF conditions Only 540 (T-H3) models In an Easy-Link system, the amount of 540 (T-H3) models called on to activate depends on the FLOW RATE and the SET TEMPERATURE.
CONFIDENTIAL 240 (T-H3J), 340 (T-H3S) and 540 (T-H3) models Service Manial Ver. 1.00 12-10. Operation time for unit rotation Only 540 (T-H3) models The unit that turns on first is whichever unit the 540 (T-H3) models decides is the primary unit. The priority unit will rotate when it reaches 100 ON/OFF cycles or after 12 hours of operation.
CONFIDENTIAL 240 (T-H3J), 340 (T-H3S) and 540 (T-H3) models Service Manial Ver. 1.00 12-11. Individual unit operation in easy-link system while parent unit is under abnormal conditions (Individual operation mode) Only 540 (T-H3) models In an easy-link system, if a parent unit undergoes abnormal conditions, the 540 (T-H3) models can operate as individual units.
CONFIDENTIAL 240 (T-H3J), 340 (T-H3S) and 540 (T-H3) models Service Manial Ver. 1.00 12-12. Easy-Link connections with previous models The 540 (T-H3) can be connected with the previous models ; 520 (T-H2). A. DIPswitch setting on the computer board of the 540 (T-H3) If a Easy-link system contains a 520 (T-H2), change DIPswitch No.6 on the lower bank all of the 540 (T-H3) computer board to the “ON”...
Page 77
CONFIDENTIAL 240 (T-H3J), 340 (T-H3S) and 540 (T-H3) models Service Manial Ver. 1.00 C-1. Temperature settings When the 540 (T-H3) is connected with any 520 (T-H2) as part of an Easy-Link system, the available set temperatures will default to what is available on a 520 (T-H2) (from 100 °F to 175 °F/185 °F as shown below).
Page 78
CONFIDENTIAL 240 (T-H3J), 340 (T-H3S) and 540 (T-H3) models Service Manial Ver. 1.00 HIGH TEMPERATURE MODE The following procedure apply only to case 1 of B. (Refer to P.76) CAUTION Operation Screen Turn on the 120 VAC power supply to the unit. Press the "ON/OFF"...
CONFIDENTIAL 240 (T-H3J), 340 (T-H3S) and 540 (T-H3) models Service Manial Ver. 1.00 12-13. High-Altitude Region Support Functions 240 (T-H3J) and 340 (T-H3S) models <Using these functions> Computer board The high-altitude region support functions have four operation levels, with the appropriate level being set up by the installer until the abnormal sound problem is solved.
Page 80
CONFIDENTIAL 240 (T-H3J), 340 (T-H3S) and 540 (T-H3) models Service Manial Ver. 1.00 Outdoor models of 240 (T-H3J) / 340 (T-H3S) : Propane DIPswitch settings Output Fan motor Level Elevation reduction speed change No.3 No.4 No.5 0 (DEFAULT) Up to 2,000 ft Up to -11 %...
Page 81
CONFIDENTIAL 240 (T-H3J), 340 (T-H3S) and 540 (T-H3) models Service Manial Ver. 1.00 540 (T-H3) models <Using these functions> computer board The desired level can be specified at the Lower bank of DIPswitches (No.2, No.3 and No.4) on the computer board. See the table below.
Page 82
CONFIDENTIAL 240 (T-H3J), 340 (T-H3S) and 540 (T-H3) models Service Manial Ver. 1.00 Outdoor models of 540 (T-H3) : Propane DIPswitch settings Output Fan motor Level Elevation reduction speed change No.2 No.3 No.4 0 (DEFAULT) Up to 2,000 ft Up to -11 % 4,000 ft Up to...
CONFIDENTIAL 240 (T-H3J), 340 (T-H3S) and 540 (T-H3) models Service Manial Ver. 1.00 12-14. Adjusting manifold gas pressure The manifold gas pressure on the water heater can be adjusted by following the procedures below. Adjusting the manifold pressure can cause unexpected combustion conditions during operation, which can cause a health hazard, damage the water heater, and/or shorten its lifespan.
Page 84
CONFIDENTIAL 240 (T-H3J), 340 (T-H3S) and 540 (T-H3) models Service Manial Ver. 1.00 Fig. 1 Fig. 2 Tube Computer board Manifold port To manometer Fig. 3 MIN button MAX button MAX button MIN button Increase button Decrease button Increase button Decrease button 240 (T-H3J) / 340 (T-H3S) models 540 (T-H3) models...
CONFIDENTIAL 240 (T-H3J), 340 (T-H3S) and 540 (T-H3) models Service Manial Ver. 1.00 12-15. Manually adjusting the fan motor speed Only 540 (T-H3)models While the FM+ DIPswitch will automatically increase the fan speed by 6%, the fan motor speed on the 540 (T-H3) models can also be manually adjusted.
CONFIDENTIAL 240 (T-H3J), 340 (T-H3S) and 540 (T-H3) models Service Manial Ver. 1.00 12-16. Freeze protection system The 240 (T-H3J) models, 340 (T-H3S) models and 540 Outdoor (T-H3-OS) models freeze protection system is comprised of the ceramic heating blocks. The ceramic heating blocks will heat up whatever portion of the heat exchanger the blocks are strapped to.
Page 87
CONFIDENTIAL 240 (T-H3J), 340 (T-H3S) and 540 (T-H3) models Service Manial Ver. 1.00 Ceramic heating blocks The two heating blocks focus on protecting the inlet and outlet piping inside the water heater, as well as the front drum pipe. The blocks will only activate based on what the freeze protection thermostat senses. The thermostat is located on the intake port for Direct Vent Indoor models, close in vicinity to the inlet and outlet pipes for Outdoor models.
CONFIDENTIAL 240 (T-H3J), 340 (T-H3S) and 540 (T-H3) models Service Manial Ver. 1.00 12-17. Draining and cleaning the inlet water filter 1. Close the manual gas shut off valve. 2. Turn off power to the water heater, wait a few seconds. And then turn on again. 3.
EK159 Case assembly for Indoor models EK164 Case assembly for Outdoor models 319143-505 EK187 Front cover for 240 and 340 Indoor (T-H3J-DV and T-H3S-DV) 319143-506 EK188 Front cover for 240 and 340 Outdoor (T-H3J-DV and T-H3S-OS) 319143-507 EK158 Front cover for 540 Indoor (T-H3-DV)
Page 94
CONFIDENTIAL 240 (T-H3J), 340 (T-H3S) and 540 (T-H3) models Service Manial Ver. 1.00 Common parts for Part # other models T-H3J, T-H3S Item # Description 240, 340 T-H3J, T-H3S 240, 340 and and T-H3 and 540 and T-H3 540 models models models models...
Page 95
CONFIDENTIAL 240 (T-H3J), 340 (T-H3S) and 540 (T-H3) models Service Manial Ver. 1.00 Common parts for Part # other models T-H3J, Item # Description 240, 340 T-H3J, T-H3S 240, 340 and T-H3S and and 540 and T-H3 540 models T-H3models models models T-K3,...
Page 96
CONFIDENTIAL 240 (T-H3J), 340 (T-H3S) and 540 (T-H3) models Service Manial Ver. 1.00 Common parts for Part # other models T-H3J, T-H3S Item # Description 240, 340 T-H3J, T-H3S 240, 340 and and T-H3 and 540 and T-H3 540 models models models models...
Page 97
Silicon ring for Outdoor models 319143-524 EK177 Exhaust port for Outdoor models 319143-525 EK198 Heat exchanger assembly for 240 and 340 Indoor (T-H3J-DV and T-H3S-DV) 319143-526 EK199 Heat exchanger assembly for 240 and 340 Outdoor (T-H3J-OS and T-H3S-OS) 319143-527 EK200...
Page 98
CONFIDENTIAL 240 (T-H3J), 340 (T-H3S) and 540 (T-H3) models Service Manial Ver. 1.00 Common parts for Part # other models T-H3J, T-H3S Item # Description 240, 340 T-H3J, T-H3S 240, 340 and and T-H3 and 540 and T-H3 540 models models models models...
Page 99
CONFIDENTIAL 240 (T-H3J), 340 (T-H3S) and 540 (T-H3) models Service Manial Ver. 1.00 Common parts for Part # other models T-H3J, T-H3S Item # Description 240, 340 T-H3J, T-H3S 240, 340 and and T-H3 and 540 and T-H3 540 models models models models...
Page 100
CONFIDENTIAL 240 (T-H3J), 340 (T-H3S) and 540 (T-H3) models Service Manial Ver. 1.00 Common parts for Part # other models T-H3J, T-H3S Item # Description 240, 340 T-H3J, T-H3S 240, 340 and and T-H3 and 540 and T-H3 540 models models models models...
Page 101
CONFIDENTIAL 240 (T-H3J), 340 (T-H3S) and 540 (T-H3) models Service Manial Ver. 1.00 Common parts for Part # other models T-H3J, T-H3S Item # Description 240, 340 T-H3J, T-H3S 240, 340 and and T-H3 and 540 and T-H3 540 models models models models...
Page 102
CONFIDENTIAL 240 (T-H3J), 340 (T-H3S) and 540 (T-H3) models Service Manial Ver. 1.00 Common parts for Part # other models T-H3J, T-H3S Item # Description 240, 340 T-H3J, T-H3S 240, 340 and and T-H3 and 540 and T-H3 540 models models models models...
Page 103
CONFIDENTIAL 240 (T-H3J), 340 (T-H3S) and 540 (T-H3) models Service Manial Ver. 1.00 Common parts for Part # other models T-H3J, T-H3S Item # Description 240, 340 T-H3J, T-H3S 240, 340 and and T-H3 and 540 and T-H3 540 models models models models...
CONFIDENTIAL 240 (T-H3J), 340 (T-H3S) and 540 (T-H3) models Service Manial Ver. 1.00 15. Revisions Version Description of changes Date 1.00 First edition 12/07/18 Page...