free hit counter
Mitsubishi MSC-GA20VB Operating Instructions Manual
Mitsubishi MSC-GA20VB Operating Instructions Manual

Mitsubishi MSC-GA20VB Operating Instructions Manual

Mitsubishi msc-ga20vb; msc-ga25vb; msc-ga35vb split type air conditioners

Advertisement

Quick Links

SPLIT-TYPE AIR CONDITIONERS
Back to Index

OPERATING INSTRUCTIONS

INDOOR UNIT
MSC-GA20VB
MSC-GA25VB
MSC-GA35VB
OPERATING INSTRUCTIONS
To use this unit correctly and safely, be sure to read this operating instructions
before use.
Bedienungsanleitung
Um diese Einheit richtig und sicher zu verwenden, unbedingt diese Bedienungs-
anleitung vor der Inbetriebnahme durchlesen.
NOTICE D'UTILISATION
Pour avoir la certitude d'utiliser cet appareil correctement et en toute sécurité, veuillez
lire attentivement cette notice d'instructions avant de mettre l'appareil en fonction.
GEBRUIKSAANWIJZING
Om dit apparaat op de juiste manier en veilig te gebruiken, dient u eerst deze
gebruiksaanwijzing aandachtig door te lezen.
MANUAL DE INSTRUCCIONES
Para emplear correctamente este aparato y por razones de seguridad debe leer
este manual de instrucciones de manejo antes de su utilización.
LIBRETTO D'ISTRUZIONI
Per utilizzare correttamente quest'unità, leggere questo libretto d'istruzioni atten-
tamente e per intero.
∆ΗΓΙΕΣ ΛΕΙΤ ΥΡΓΙΑΣ
°È· Ó· ¯ÚËÛÈÌÔÔÈ‹ÛÂÙ ·˘Ù‹ ÙËÓ ÌÔÓ¿‰· ÛˆÛÙ¿ Î·È Ì ·ÛÊ¿ÏÂÈ·, ‚‚·Èˆı›ÙÂ
fiÙÈ ¤¯ÂÙ ‰È·‚¿ÛÂÈ ·˘Ùfi ÙÔ ÂÁ¯ÂÈÚ›‰ÈÔ Ô‰ËÁÈÒÓ ÚÈÓ ·fi ÙËÓ ¯Ú‹ÛË.
INSTRUÇÕES DE OPERAÇÃO
Para utilizar esta unidade correctamente, certifique-se de que lê estas instruções
de operação antes da utilização.
BRUGSANVISNING
Læs denne brugsanvisning før brugen så korrekt og forsvarlig anvendelse af klima-
anlægget sikres.
BRUKSANVISNING
För att använda enheten på rätt och säkert sätt ska denna bruksanvisning läsas
innan enheten tas i bruk.
‹fiLETME TAL‹MATLARI
‹fiLETME TAL‹MATLARI
‹fiLETME TAL‹MATLARI
‹fiLETME TAL‹MATLARI
‹fiLETME TAL‹MATLARI
Bu birimi do¤ru ve güvenli olarak çal›flt›rmak için, kullanmadan önce bu iflletme
talimatlar›n› mutlaka okuyun.
РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ
Для обеспечения правильного и безопасного использования прибора следует
до начала его эксплуатации внимательно прочитать данное руководство.
For customers
English
Für Kunden
Deutsch
A l'attention des clients
Français
Voor de klant
Nederlands
Para los clientes
Español
Per gli utenti
Italiano
°È· ÙÔÓ ÂÏ¿ÙË
∂ÏÏËÓÈο
Para os clientes
Português
Til kunden
För kunder
Svenska
Sat›n al›c›lar için
Türkçe
Для пользователей
Русский
Dansk

Advertisement

Table of Contents
loading

Summary of Contents for Mitsubishi MSC-GA20VB

  • Page 1: Operating Instructions

    INDOOR UNIT GEBRUIKSAANWIJZING Voor de klant Nederlands MSC-GA20VB • Om dit apparaat op de juiste manier en veilig te gebruiken, dient u eerst deze gebruiksaanwijzing aandachtig door te lezen. MSC-GA25VB...
  • Page 2: Table Of Contents

    CONTENTS • This air conditioner is NOT intended for use by children or infirm persons without supervisions. SAFETY PRECAUTIONS ................................ 2 NAME OF EACH PART ................................3 WARNING PREPARATION BEFORE OPERATION ..........................4 I FEEL... AUTO OPERATION ..............................6 Do not use intermediate connection of the power supply cord or the extension cord and do not MANUAL OPERATION (COOL, DRY, HEAT/FAN) ........................
  • Page 3: Name Of Each Part

    SAFETY PRECAUTIONS NAME OF EACH PART Indoor unit CAUTION Do not use the unit for special purposes. Front panel • Do not use this air conditioner to preserve precision devices, food, animals, plants and art objects. Air cleaning filter Air inlet This may cause deterioration of quality, etc.
  • Page 4: Preparation Before Operation

    NAME OF EACH PART PREPARATION BEFORE OPERATION PREPARATION BEFORE OPERATION PREPARATION BEFORE OPERATION Remote controller Auto restart function Auto restart function Auto restart function These models are equipped with an auto restart function. If you do not want to use this function, Signal transmitting section please consult the service representative because the setting of the unit needs to be changed.
  • Page 5: Preparation Before Operation

    PREPARATION BEFORE OPERATION Handling of the remote controller Remote controller When the remote controller cannot be used (emergency operation) • The range that the signal can reach is about 6 m when the remote controller is pointed at the front of the When the batteries of the remote controller run out or the remote controller malfunctions, the emergency operation How to set the batteries and the current indoor unit.
  • Page 6: I Feel

    I FEEL... AUTO OPERATION With the “ (I FEEL...)” auto operation mode, the optimum room condition can be set automatically Description of “I FEEL...” mode with a one-touch operation. Details of operation To start operation: According to the room temperature when the operation starts, the operation mode is automatically set to COOL, DRY or ON/OFF Press the button.
  • Page 7: Manual Operation (Cool, Dry, Heat/Fan)

    MANUAL OPERATION (COOL, DRY, HEAT/FAN) AIR FLOW VELOCITY AND DIRECTION ADJUSTMENT AIR FLOW velocity and direction can be selected as required. To select the COOL, DRY or HEAT/FAN mode: To change the AIR FLOW velocity, press the button. ON/OFF Press the button.
  • Page 8: Econo Cool Operation

    ECONO COOL OPERATION WHEN THE AIR CONDITIONER IS NOT GOING TO BE USED FOR A LONG TIME Use this operation when you want to be comfortable in COOL mode even with energy saved. Perform the following operations while the unit is operat- When it is not going to be used for a long When the air conditioner is to be used ing in the MANUAL COOL mode.
  • Page 9: Cleaning The Catechin Air Filter

    CLEANING THE CATECHIN AIR FILTER REPLACEMENT OF THE AIR CLEANING FILTER (OPTION) When the capacity is lowered because of dirt, etc., it is necessary to replace the air cleaning filter. Cleaning the catechin air filter (about once every 2 weeks) Air cleaning filter replacement (about once every 4 months) After washing with water/lukewarm water, dry Remove the catechin air filter.
  • Page 10: Before Contacting The Service Representative, Check The Following Again

    BEFORE CONTACTING THE SERVICE REPRE- WHEN YOU THINK THAT TROUBLE HAS OCCURRED SENTATIVE, CHECK THE FOLLOWING AGAIN Question Answer (not a malfunction) Question Answer (not a malfunction) The air conditioner cannot • This protects the air conditioner according to in- The air flow direction •...
  • Page 11: Installation, Relocation And Inspection

    Consult your dealer. If you have any questions, consult your dealer. SPECIFICATIONS NOTE: Set name MSH-GA20VB MSH-GA25VB MSH-GA35VB MS-GA20VB MS-GA25VB MS-GA35VB 1. Rating condition Model Indoor MSC-GA20VB MSC-GA25VB MSC-GA35VB MSC-GA20VB MSC-GA25VB MSC-GA35VB Outdoor MUH-GA20VB MUH-GA25VB MUH-GA35VB MU-GA20VB MU-GA25VB MU-GA35VB Cooling —...
  • Page 12 This product is designed and intended for use in the residential, commercial and light-industrial environment. The product at hand is based on • Low Voltage Directive 73/23/ EEC the following EU regulations: • Electromagnetic Compatibility Directive 89/336/ EEC HEAD OFFICE: MITSUBISHI DENKI BLDG., 2-2-3, MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN SG79Y369H01...

This manual is also suitable for:

Msc-ga35vbMsc-ga25vb