The following illustration shows the correct location of each label.
21
20
19
18
17
16
16
1
GEO label
2
Taiwan WWAN label (only for Taiwan)
3
FCC label
4
System label
5
Windows COA label
6
Non-encription label (for non-TPM model) or Indonesia
rating label
7
Information label
8
S/N label
9
Asset tag
10
IMEI label
11
Wireless label for special bid
1180 System board assembly and RJ45 sub card
Important notices for handling the system board:
When handling the system board, bear the following in mind:
• The system board has an accelerometer, which can be broken if several thousands of G-forces are applied.
Note: Dropping a system board from a height of as little as 6 inches so that it falls flat on a hard bench can subject
the accelerometer to as much as 6,000 G's of shock.
• Be careful not to drop the system board on a bench top that has a hard surface, such as metal, wood, or composite.
• If a system board is dropped, be sure to document the drop in any reject report, and replace the system board.
• Avoid rough handling of any kind.
• At every point in the process, be sure not to drop or stack the system board.
• If you put a system board down, be sure to put it only on a padded surface such as an ESD mat or a corrugated
conductive surface.
For access, remove these FRUs in order:
•
"1010 Battery pack" on page 62
94
Hardware Maintenance Manual
1 2 3 4 5
22
15
14
13
12
6
7
8
12
Asset tag
13
Wireless card label
14
Bluetooth label (only for Brazil)
15
Brazil WWAN label (only for Brazil)
16
SIRIM label or Indonesia POSTEL label
17
China telcom label
18
Israel label
19
China 3G logo WWAN label
20
China WWAN label
21
China 3G WWAN label
22
China GEO label (only for China)
9
10
11