Basic Code: AR12HSSDPWKNEE AR18HSFSAWKXEU Model Code: AR09JSFDHWKNCV AR09JSFDHWKXCV AR12JSFDHWKNCV AR12JSFDHWKXCV 5. Control Exploded Views And Part List...
Do not place a cloth or other materials over it. O Remove the batteries if you don't use the remote control for a long time. (If applicable) O Use the remote control within 7 meters from the indoor unit. (If applicable) Samsung Electronics...
O Young children or infirm persons should be always supervised when they use the air conditioner. O Max current is measured according to IEC standard for safety. O Current is measured according to ISO standard for energy efficiency. Samsung Electronics...
Smart Installation Smart Check - Don’t worry about the trouble-shooting in your home Triple Protector Plus - Use longer without damage in unsuitable conditions Easy Installation - Secure the easy Installation of Indoor unit and pipe connection Easy Filter Samsung Electronics...
Because the teat mode operate the cool mode by force not related to the set temperature / indoor temperature, check whether each subordinate is operated normally or not after completing installation Note and must turn off the power of the air conditioner. Samsung Electronics...
1. Tack out the batteries of remote control. 2. Press the temperature button simultaneously and insert the battery again. 3. Make sure the remote control display shown as Step 2 Enter the Options Setup mode and select your options asscording to the following procedure. Samsung Electronics...
2) Detach FILTER PRE from the PANEL FRONT. 3) Cover Panel is assembled on bottom of indoor unit as shown in the figure. Remove the Cap Screw as shown on the right side and then remove the screw and separate the Cover Panel. Samsung Electronics...
Page 21
5) Separate the hook after pushing both end of Cover Panel as shown in the figure. (Watch out for the damage of the hook) 6) Raise front part upward obliquely as shown in the figure and then remove the hooks. Samsung Electronics...
Page 22
Assembly of Cover Panel after service end. - Reassembly is in the reverse order of the removal. - Piping and drain hose must be careful not to damage and Progress must be done with both hands. Hook (Side) Hook (Center) Screw Cap Screw Samsung Electronics...
Page 23
4 HOOK Structures. When separate the hook : Use the (-) screw Driver. (-)Screw Driver Insert the hook and then pull the hook as shown on the right side. (Watch out for the damage of the hook) Samsung Electronics...
Page 24
Parts Procedure Remark 9) Remove the Panel Frame from the Main Frame as shown on the right side. 10) Remove the WIFI KIT connector. WIFI KIT connector is located of Panel Front. (For model with WIFI KIT) Samsung Electronics...
Page 25
9) Take off the CASE-CONTROL from the main frame after loosen the remaining connector. Caution: When you separate the connector, pull pressing the locking button. TRAY DRAIN 1) To detach TRAY-DRAIN from the main frame, pull the bottom of the TRAY-DRAIN towards you. Samsung Electronics...
Page 26
2) Unfasten the screw at the left side. (use + Screw Driver) 3) Unfasten the screw at the right side. (use + Screw Driver) 4) To detach Evaporator from the main frame, pull the bottom of the Evaporator towards you. Samsung Electronics...
Page 27
FAN MOTOR 1) Unfasten the screw. (use + Screw Driver) & CROSS FAN 2) Detach the FAN Motor case. 3) Unfasten the screw a little. (use + Screw Driver) 4) Pull the CROSS-FAN to the left side. 4-10 Samsung Electronics...
Page 28
- Confirm Seal of backside necessarily after replace of Assy SPI Lamp. - Seal should be close adhesion to SPI Lamp. - Measure as shown on the right side since replace. (If the seal is not close adhesion perfectly : Defectiveness can happen) Samsung Electronics 4-11...
CASE from Case-WIFI Button Separate Case-WIFI Top BUTTON from Case-WIFI Button Detach Assy Connector Wire from Case-WIFI Button WIRE *Caution When you separate the connector , pull press -ing the locking button Separate PBA WIFI from Case-WIFI Button Samsung Electronics...
Wi-Fi module Air intake (up and down) (left and right) Display Temperature indicator / Filter Reset indicator Defrost indicator Power consumption indicator / Auto clean indicator Power button/ Wi-Fi indicator Remote controller receiver Timer/ Auto clean indicator Samsung Electronics...
In case you wish to cancel the options or settings that you have just set, press the button again, then the most recently selected item will blink and you may simply cancel it by pressing the SET button while selected item is blinking. Samsung Electronics...
HEAT mode, and indoor fan and out- Indoor fan and outdoor fan stop operation door fan do not operate intermittently for within 20% intermittently in a HEAT mode. of the total heater operation. Samsung Electronics 10-1...
Is the power is normal? Exchange the PBA of no power unit (check the LED Lamp) Exchange the indoor unit PBA. Is the communication error occurred again? Terminate the service. Exchange the outdoor unit PBA. 10-2 Samsung Electronics...
Page 59
Is the connection of power cable supply power and measure the voltage of #1-#2 in and communication cable normal? the connector Exchange the indoor PBA Below 0.5V or Over 4.5V? Micom error or connector check Exchange the indoor PBA Samsung Electronics 10-3...
Page 60
Is the connection of power cable supply power and measure the voltage of #3-#4 and communication cable normal? and #5-#6 in the connector Exchange the indoor PBA Below 0.5V or Over 4.5V? Micom error or connector check Exchange the indoor PBA 10-4 Samsung Electronics...
Page 61
Is the connected louver wire? Does operation start when swing button of the Normal remote control unit pushed? Is the voltage changeable at the pin#2~#5 of CN61, Exchange the PBA CN62, CN63 (louver connector)? Up/Down louver motor is faulty. Samsung Electronics 10-5...
Page 62
Is the voltage of CN72 Exchange the Indoor PBA #3-#5 and #3-#6 with in 1Vdc~15Vdc during the operation? PBA problem or Motor problem Change the PBA first and check the operation Exchange the Fan motor 10-6 Samsung Electronics...
Is the connection of power cable supply power and measure the voltage of "B"in the connector and communication cable normal? Exchange the Outdoor PBA Below 0.5Vdc or Over 4.5Vdc? Micom error or connector check Exchange the Outdoor PBA Samsung Electronics 10-7...
Page 64
Is the connection of power cable supply power and measure the voltage of "B" in the connector and communication cable normal? Exchange the Outdoor PBA Below 0.5Vdc or Over 4.5Vdc? Micom error or connector check Exchange the Outdoor PBA 10-8 Samsung Electronics...
Page 65
Is the connection of power cable supply power and measure the voltage of "B"in the connector and communication cable normal? Exchange the Outdoor PBA Below 0.5Vdc or Over 4.5Vdc? Micom error or connector check Exchange the Outdoor PBA Samsung Electronics 10-9...
Page 66
Restart after power off Is the discharge over temperature Terminate the service sensor error appeared again? Download the EEPROM data Is the discharge over temperature Terminate the service sensor error appeared again? Exchange the Outdoor PBA Exchanged the Compressor 10-10 Samsung Electronics...
Is the voltage of "A" #3-#5 and Exchange the Outdoor PBA #3-#6 with in 1Vdc~15Vdc during the operation? PBA problem or Motor problem Change the PBA first and check the operation Exchange the Fan motor Samsung Electronics 10-11...
Is the connection of compressor wire is normal? Connect the comp wire normally Download the EEPROM data Is the restart error occurred again? Terminate the service Is the compressor body and interphase Exchange the Outdoor PBA resistance insulated? Exchange the compressor 10-12 Samsung Electronics...
Page 69
Is the connection of compressor wire is normal? Connect the comp wire normally (PBA and Compressor) Is the restart error occurred again? Terminate the service Is the compressor body and Exchange the Outdoor PBA interphase resistance insulated? Exchange the compressor Samsung Electronics 10-13...
Page 70
Connect the comp wire normally Is the O.C error occurred again? Terminate the service Is the condition of indoor/outdoor temperature Restart after returning to the normal load normal load? Is the O.C error Terminate the service occurred again? 10-14 Samsung Electronics...
Page 71
Is the position of Correct the sensor position or temperature sensor and sensing exchange the sensor value normal? Is the compressor body and interphase resistance Exchange the Outdoor PBA insulated? Exchange the compressor Samsung Electronics 10-15...
Page 72
("A") is normal in operation mode? Check the power input Normal range(280Vdc~320Vdc) Is the DC_link sensing voltage("B") is normal in operation mode? Exchange the Outdoor PBA Normal range (0.2Vdc~4.8Vdc) Exchange the Outdoor PBA Is the reactor insulation damaged? Exchange the Reactor 10-16 Samsung Electronics...
Page 73
Start the operation (cooling mode or heating mode) Is the DC_link sensing voltage("B") is normal in operation mode? Exchange the Outdoor PBA Normal range (0.2Vdc~4.8Vdc) Exchange the Outdoor PBA Is the reactor insulation damaged? Exchange the Reactor Samsung Electronics 10-17...
Page 74
Check the input power in the powercord. Normal range(180Vac ~ 270Vac) Restart after power off. Start the operation (cooling mode or heating mode) Is the DC_link voltage ("A") is normal in operation mode? Check the input power Normal range(280Vdc~320Vdc) 10-18 Samsung Electronics...
Page 75
Is the DC_link sensing voltage("D")is normal in operation mode? Exchange the Outdoor PBA Normal range (0.2Vdc~4.0Vdc) Exchange the Outdoor PBA Is the reactor insulation damaged? Exchange the Reactor Samsung Electronics 10-19...
Page 76
Is the position of Correct the sensor position or temperature sensor and the sensing exchange the sensor value normal? Is the connection cable for the compressor and power Correct the cable connection terminal normal? Exchange the Outdoor PBA 10-20 Samsung Electronics...
Page 77
IC451 R408,R409,R410 DB92-02867A R063,R064,R065 IC451 Restart after power off. Is the PFC shunt and IPM Exchange the Outdoor PBA shunt resistance value correct? Is the current sensor error appeared again? Terminate the service Exchange the Outdoor PBA Samsung Electronics 10-21...
Page 78
4) Is the cover assembly in control-box normal? 2. Troubleshooting procedure Restart after power off. Are there screws in PBA-heatsink? Fastening the screw (4 screws) Check the fan connection Is the fan operation normal? Change the Fan motor Exchange the Outdoor PBA 10-22 Samsung Electronics...
Page 79
Is the Comp Vlimit error occurred again? Terminate the service Is the condition of indoor/outdoor temperature Restart after returning to the normal load normal load? Is the O.C error Terminate the occurred again? service Samsung Electronics 10-23...
Page 80
Is the position of Correct the sensor position or temperature sensor and sensing exchange the sensor value normal? Is the compressor body and interphase resistance Exchange the Outdoor PBA insulated? Exchange the compressor 10-24 Samsung Electronics...
Page 81
2. Troubleshooting procedure MODEL "A" DB92-02866A CN501 DB92-02867A CN202 power off and download EEPROM data (or. Insert the service EEPROM IC) Restart after power off Terminate the service Is the error appeared again? Exchange the Outdoor PBA Samsung Electronics 10-25...
Page 82
* Heating mode * * Cooling mode * Is the outdoor temperature over 40 or Is the outdoor temperature under -7 under -30 ? The temperature condition is too poor to operate. Wait until temperature is changed 10-26 Samsung Electronics...
Page 83
Terminate the service. Check the EEV valve operation. Is the EEV valve connection normal? Connect the EEV valve. Is the EEV valve is operation? Check the sound of EEV valve Change the EEV valve. after power on. Samsung Electronics 10-27...
Page 84
Check the pipe crack. Is the pressure of refrigerant normal? Fill up the refrigerant. Exchange the Indoor PBA Exchange the Outdoor PBA 10-28 Samsung Electronics...
Page 85
Check the fuse open or not? (F001) Exchange the Main PBA Restart after power off. Is the power normal? Check the power source. Is AC power is normal for SMPS? Exchange the Main PBA CN150 : 220Vac~240Vac Check SMPS wire connection Samsung Electronics 10-29...
Page 86
DC wire (3PIN RED, 3PIN BLU) with Main PBA Connector CN151, CN152, Check the DC voltage in Exchange the Main PBA Main PBA. Is the voltage is normal in Main PBA? (Main : CN151,CN152 Check) Exchange the Main PBA, SMPS PBA 10-30 Samsung Electronics...
Page 87
Is the SMPS is normal? Exchange the SMPS PBA "G" Main 12V : 11Vdc ~ 13Vdc Is the SMPS is normal? Exchange the SMPS PBA "H" Main 5V : 4. 5 Vdc ~ 5. 5 Vdc Exchange the PBA Samsung Electronics 10-31...
Page 88
1) Check the power condition at customer's house (Is there any power noise?) 2) Have been there power failure? 2. Troubleshooting procedure MODEL Error display DB92-02866A/2867A Restart after power off Is the AC line zero cross signal error appeared again? Terminate the service Exchange the Outdoor PBA 10-32 Samsung Electronics...
Page 89
Reset the option code again at indoor unit Is the capacity miss match error appeared again? Terminate the service Download the EEPROM data Is the capacity miss match error appeared again? Terminate the service Exchange the Outdoor PBA Exchange the Indoor PBA Samsung Electronics 10-33...
Page 90
2) Check the battery in remote control 3) All the lights out and check again : Change electronic typed to a fluorescent light 4) Put the set in operation and check the voltage of display PBA 5) Replace the display PBA 10-34 Samsung Electronics...
Page 91
Is the EEV valve is operation? Change the EEV valve. Check the sound of EEV valve after power on. Check the pipe crack. Is the pressure of refrigerant normal? Fill up the refrigerant. Exchange the Indoor PBA Exchange the Outdoor PBA Samsung Electronics 10-35...
Page 92
- Discharge temperature and the indoor [Execute the troubleshooting] temperature measurements confirm Check the refrigerant leaks. that the difference is more than 10 . Check the PCB Relay. - Fill up perfectly refrigerant after re-vacuum. Execute the related trouble- shooting. 10-36 Samsung Electronics...
2) The fan motor of the indoor unit . Fan motor connector(CN72) is faulty. 1. Fan speed(high) doesn't run. 2. Continuous Operation 3) The power voltage between terminal #1-#3 of the . PBA is faulty. connector(CN72) is 0V. Samsung Electronics 10-37...
Page 94
(There is no problem with Main PBA in this case) - In the above case, the change of all-in-one Terminal Block will make Main PBA operate again. Circuit Block 3. Measurement method of fair/defective thermal fuse Fail Defective 10-38 Samsung Electronics...
Page 97
2) The fan motor of the indoor unit . Fan motor connector(CN72) is 1. Fan speed(high) doesn't run faulty 2. Continuous Operation 3) The power voltage between terminal #3-#5 of the . PBA is faulty connector(CN72) is 0V Samsung Electronics 11-3...
It occurs when the drain pump is plugged out or it is out of order. Check the power of the drain pump and the position of the drain hose, and when the pump is faulty, contact the drain pump manufacturer. Samsung Electronics do not manufacture drain pumps. So, we are not able to correct the drain pump problems.
Page 101
Also, the remote con- troller may mot work under intensive light from a 3-wave length lamp or a neon sign due to the EMI. In this case, take the remote controller closer to the receiver. Samsung Electronics 12-3...
Page 102
There is a cost table. But, our service engineer needs to visit to total up the cost correctly. When you move in, make sure to contact Samsung Electronics Service Center or Authorized Service Agent in advance to streamline the process.
Electric and earth work shall meet the "Electric Facility Technology Standard" and the "Internal Wire Regulation" of the Electric Business Laws. Inspection & Trial Run Upon completion of the tests, you shall make a trial run while you explain the main functions of the air conditioner to finish the installation. 12-6 Samsung Electronics...
3 way valve. And mount the service port cap to 3 way valve. Valve stem Stem cap 7) Check for gas leakage. (gas) - At this time, especially check for gas leakage from the 3 way valve's stem nuts, and from the service port cap. (liquid) Samsung Electronics 12-7...
7) Close the cap of each valve. Relocation of the air conditioner entering. At this time, cover the valve of the outdoor unit and the other pipe using a cap or vinyl plug to avoid foreign material entering. 12-8 Samsung Electronics...
12-7.Reference Sheet Index for Model Name 10th 11th 12th 13th 14th Project Capacity Sell Feature Series Color Export Unit Item Reference 3TH 4TH Item ITEM Item Export 12Year INVERTER HP Export 13Year INVERTER CO Export 14Year Export 15Year Export 16Year Item2 9TH DIGIT Item1...