free hit counter
Download Print this page

Zephyr Milano Wall ZMI-M90BS Use, Care And Installation Manual

Hide thumbs Also See for Milano Wall ZMI-M90BS:

Advertisement

Available languages

Available languages

www.zephyronline.com
Milano Wall
ZMI-M90BS
ZMI-M90BG
C
TM
Model number:
Airflow Control Technology
Serial Number:
JUL12.0401 © Zephyr Corporation

Advertisement

loading

Summary of Contents for Zephyr Milano Wall ZMI-M90BS

  • Page 1 Milano Wall ZMI-M90BS ZMI-M90BG Model number: Airflow Control Technology Serial Number: JUL12.0401 © Zephyr Corporation...
  • Page 2 www.zephyronline.com...
  • Page 3 SAFETY NOTICE ..............LIST OF MATERIALS ............INSTALLATION Ducting Calculation Sheet ........Mounting Height & Clearance ........ Ducting Options ............Hood Specifi cations ........... Mounting the Range Hood ........Ductless Recirculating ..........FEATURES & CONTROLS Touch Controls ............. User Interface ...............
  • Page 4 www.zephyronline.com READ AND SAVE THESE INSTRUCTIONS WARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT USE THIS FAN WITH ANY SOLID-STATE CONTROL DEVICE. WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: a.
  • Page 5: Operation

    ZMI-M90BG - 212 Watts, 3.5 Amps Power consumption shown above is the default power specs. Hoods with Zephyr’s proprietary Airfl ow Control Technology (ACT) enabled will consume less power. See wiring diagram at the end of this manual for more information.
  • Page 6: Hardware Package Contents

    www.zephyronline.com MODELS: ZMI-M90BS, ZMI-M90BG PARTS SUPPLIED 1 - Duct cover wall bracket 1 - Duct cover assembly, top and bottom 1 - Hardware package 1 - 8” round damper, pre-installed 1 - Hood body with internal blower 1 - Canopy , glass or stainless steel 3 - 3W LED light bulbs 1 - Aluminum mesh filter HARDWARE PACKAGE CONTENTS...
  • Page 7 Equivalent number Equivalent number Duct pieces Duct pieces length x used T otal length x used T otal 3- 1/ 4” x 10” 1 Ft. 6”- 8” Round 30 Ft. Rect., wall cap straight with damper 7” Round, 1 Ft. 6”- 8”...
  • Page 8 www.zephyronline.com ALWAYS, when possible, reduce the number of transitions and turns. If a long duct run is required, increase duct size from 8” to 10”. If turns or transitions are required: Install as far away from duct opening and as far apart between the two transitions as possible.
  • Page 9 WARNING FIRE HAZARD NEVER exhaust air or terminate duct work into spaces between walls, crawl spaces, ceiling, attics or garages. All exhaust must be ducted to the outside, unless using the recirculating option. Use single wall rigid Metal ductwork only. Fasten all connections with sheet metal screws and tape all joints w/ certifi...
  • Page 10 www.zephyronline.com front of hood side of hood 12 13/16” 13 5/8” 8 3/8” STANDARD min. ducted - 26 ” min. recirc. - 31” max. - 50” Z1C-01MI min. ducted - 42” min. recirc. - 46” max. - 80” 23 15/16” 35 3/16”...
  • Page 11 CAUTION: At least two installers are required due to the weight and size of the hood. 1. Measure from range top to hood bottom and mark line A. (26” minimum from range top) . 11 1/4” 2. Plum and mark center line. 3.
  • Page 12 www.zephyronline.com Ductless recirculation is intended for applications where an exhaust duct work is not possible to be installed. When converted, the hood functions as a recirculating hood rather than an exhaust hood. Fumes and exhaust from cooking are drawn and fi ltered by a set of optional charcoal fi lters. The air is then purifi ed and re- circulated back within the home.
  • Page 13 Display (speed level, delay off, filter clean/change,clean air) Power / Delay Off clean mesh filter clean air replace charcoal filter Lights On/Dim/Off Adjust 6 Speed Levels 1 Power / Delay Off Button Power Button Function Button will turn power on and off for entire hood (fan and lights). - Hood will remember the last speed and light level it was turned off at.
  • Page 14 www.zephyronline.com Mesh Filter Clean Indicator (always enabled) - After 30 hours of fan usage the Graphic and words “ ” will illuminate indicating it is time to clean clean mesh filter the mesh filters. Graphic and words will remain illuminated until reset. - To reset: With hood off, hold the Button for three seconds, after three seconds the Graphic and words “...
  • Page 15: Surface Maintenance

    SURFACE MAINTENANCE: Clean the hood surface periodically with hot soapy water and clean cotton cloth. Do not use corrosive or abrasive detergent, or steel wool/scouring pads which will scratch and damage surface. For heavier soil use liquid degreaser. After cleaning it is recommended that you use non-abrasive stainless steel polish/cleaners, to polish and buff out the stainless luster and grain.
  • Page 16 www.zephyronline.com TROUBLESHOOTING PROCEDURES FOR MILANO WALL Issue Cause What to do After installation, 1. The power source is not turned ON. 1. Make sure the circuit breaker and the unit’s the unit doesn’t power is ON. work. 2. The power line and the cable locking connector 2.
  • Page 17 Some local codes limit the maximum amount of CFM a range hood can move. ACT allows you to control the maximum blower CFM of hoods with Zephyr’s DCBL Suppression System without the need for expensive make up air kits. ACT enables the installer to easily set the maximum blower speed to one of three most commonly specifi...
  • Page 18 www.zephyronline.com...
  • Page 19 Model: ZMI-M90BG/M90BS Voltage 120V 60Hz Power consumption Total: Max. 212W @ 3.5A Lamp: Max. 3Wx3 5A 250V Fan: Max. 203W AC-N AC-L THERMALLY PROTECTED ON/OFF DOWN LAMP Power consumption shown for default 715 CFM blower confi guration ACT 590 CFM - Fan Max. 130W @ 1.8A ACT 440 CFM - Fan Max.
  • Page 20 www.zephyronline.com DESCRIPTION PART# Replacement Parts Light Bulb 3W LED (each) Z0B-0032 Aluminum Mesh Filter (each) 50200044 Optional Accessories Recirculating Kit ZRC-00MI Replacement Charcoal Filter Z0F-C002 Duct Cover Extension Z1C-01MI Gray Glass Canopy 36” ZMG-02GY To order parts, visit us online at http://store.zephyronline.com or call us at 1.888.880.8368...
  • Page 21: Limited Warranty

    Zephyr Corporation (referred to herein as “we” or “us”) warrants to the original consumer purchaser (referred to herein as “you” or “your”) of Zephyr products (the “Products”) that such Products will be free from defects in materials or work- manship as follows: Three Year Limited Warranty for Parts and LED lamps: For three years from the date of your original purchase of the Products, we will provide, free of charge, Products or parts to replace those that failed due to manufacturing defects.
  • Page 22 Milano Wall ZMI-M90BS ZMI-M90BG Numéro de modèle : _________________ Numéro de série : _________________ Airflow Control Technology JUL12.0401 © Zephyr Corporation...
  • Page 23 www.zephyronline.com...
  • Page 24 MISE EN GARDE DE SÉCURITÉ ......LISTE DU MATÉRIEL ............INSTALLATION Feuille de calcul pour le conduit ......Espace libre et hauteur de montage ....Options d’installation pour le conduit ....Spécifi cations de la hotte ......... Montage de la hotte ...........
  • Page 25 LISEZ ET CONSERVEZ CES INSTRUCTIONS www.zephyronline.com AVERTISSEMENT POUR RÉDUIRE LES RISQUES D’INCENDIE OU DE DÉCHARGE ÉLECTRIQUE, N’UTILISEZ PAS CET APPAREIL AVEC UN TABLEAU DE COMMANDE À SEMI-CONDUCTEURS. AVERTISSEMENT POUR RÉDUIRE LES RISQUES D’INCENDIE, DE DÉCHARGE ÉLECTRIQUE OU DE BLESSURE, RESPECTEZ CES CONSIGNES : a.
  • Page 26: Exigences Électriques

    ZMI-M90BG – 212 Watts, 3.5 Ampères Consommation ci-dessus est des spécifi cations d’alimentation par défaut. Hottes avec Zephyr technologie écoulement d’air de contrôle exclusif (ACT) a permis consomme moins d’énergie. Voir le schéma de câblage à la fi n de ce manuel...
  • Page 27: Pièces Non Fournies

    www.zephyronline.com MODÈLES : ZMI-M90BS, ZMI-M90BG PIÈCES FOURNIES 1 - Support mural de recouvrement de conduit 1 - Pièce de recouvrement de conduit, haut et bas 1 - Trousse de quincaillerie 1 - Registre circulaire de 8”, préinstallé 1 - Boîtier de la hotte avec ventilateur interne 1 - Pavillon, verre ou inox 3 - Ampoules DEL 3W 1 - Filtre à...
  • Page 28 Equivalent number Equivalent number Duct pieces Duct pieces length x used T otal length x used T otal 3- 1/ 4” x 10” 1 Ft. 6”- 8” Round 30 Ft. Rect., wall cap straight with damper 7” Round, 1 Ft. 6”- 8”...
  • Page 29 www.zephyronline.com possible l’un de l’autre. La hauteur de montage minimale ne devrait pas être moins de 26”. La hauteur de montage maximale ne devrait pas outrepasser 34”. x . C Il est important d’installer la hotte à la hauteur de montage adéquate. Les hottes installées x .
  • Page 30 AVERTISSEMENT DE RISQUE D’INCENDIE N’évacuez ou ne terminez JAMAIS l’échappement du conduit dans les espaces entre les murs, les vides sanitaires, le plafond, le grenier, ou le garage. Tous les échappements doivent être dirigés à l’extérieur de la maison, à moins que l’option de reprise d’air ne soit utilisée. N’utilisez que des conduits en métal pour cloison simple.
  • Page 31 www.zephyronline.com Devant de la hotte Côté de la hotte 12 13/16” 13 5/8” 8 3/8” STANDARD Min. avec conduit - 26 ” Min. avec reprise d’air - 31” max. - 50” Z1C-01MI Min. avec conduit - 42” Min. avec reprise d’air - 46” max.
  • Page 32 ATTENTION : Compte tenu du poids et des dimensions de la hotte, au moins deux installateurs sont nécessaires. 1. Prenez la mesure entre la surface de la cuisinière et la base de la hotte; marquez la ligne A (min. 26” à partir du dessus de la cuisinière). Support pour le 2.
  • Page 33 www.zephyronline.com La confi guration de reprise sans conduit a été conçue pour les applications où il est impossible d’installer un conduit d’aération. Lorsque transformée, la hotte fonctionne comme une hotte de reprise d’air plutôt que comme un système d’évacuation d’air. Les vapeurs et fumées de cuisson sont aspirées et fi ltrées par un ensemble optionnel de fi ltres à charbon.
  • Page 34 Touche de mise en Affichage (vitesse, arrêt automatique, nettoyage/changement des filtres, purificat marche/arrêt automatique clean mesh filter clean air replace charcoal filter Lumières : Allumer/Veilleuse/É Choix de six vitesses 1-Touche de mise en marche/arrêt automatique Fonction de mise en marche - La touche permet d’allumer et d’éteindre la hotte (ventilateur et lumières).
  • Page 35 www.zephyronline.com Indicateur de nettoyage des filtres à tamis (toujours en fonction) - Après 30 heures d’utilisation du ventilateur, le symbole et les mots « clean mesh filter » s’illuminent, indiquant qu’il est temps de nettoyer les filtres à tamis. Le symbole et les mots restent illuminés jusqu’à la réinitialisation de la fonction. - Pour réinitialiser : Lorsque la hotte est éteinte, appuyez et tenez la touche enfoncée pendant trois secondes.
  • Page 36 ENTRETIEN DES SURFACES: Nettoyez régulièrement les surfaces de la hotte avec de l’eau savonneuse chaude et un chiffon de coton propre. N’utilisez pas de détergent abrasif ou corrosif, de laines d’acier ou de tampons à récurer; ils égratigneront et endommageront les surfaces. Pour les taches plus tenaces, utilisez du produit dégraissant liquide.
  • Page 37 www.zephyronline.com PROCÉDURES DE DÉPANNAGE POUR LA HOTTE MILANO WALL Problème Cause Solution Après 1. Le bloc d’alimentation n’est pas allumé 1. Assurez-vous que l’alimentation du disjoncteur l’installation, et de l’appareil est allumée l’appareil ne 2. La ligne électrique et le raccord de câble ne sont 2.
  • Page 38 ACT vous permet de contrôler le maximum CFM de les hottes avec le système de répression DCBL à partir de Zephyr sans avoir besoin de coûteux kits pour l’air de remplacement. ACT permet à l’installateur de régler facilement la vitesse maximale du ventilateur à l’un des trois les plus couramment prescrits niveaux de CFM;...
  • Page 39 www.zephyronline.com...
  • Page 40 SCHÉMA DE CIRCUITS MOTEUR DEL DEL Modèle : ZMI-M90BG/M90BS 120V 60Hz Tension : BRANCHEMENT DES COMMANDES Consommation d’énergie Total: Max. 212W @ 3.5A Lampe : Max. 3Wx3 5A 250V Ventilateur : Max. 203W AC-N AC-L CCI DES COMMANDES BOÎTIER PROTÉGÉ THERMIQUEMENT HAUT LAMPE ON/OFF...
  • Page 41 www.zephyronline.com DESCRIPTION DE PIÈCE Pièces de remplacement Ampoule DEL 3W (chaque) Z0B-0032 Filtre à tamis en aluminium (chaque) 50200044 Accessoires optionnels Ensemble de reprise d’air ZRC-00MI Filtre à charbon de remplacement Z0F-C002 Ensemble de prolongement de recouvrement de conduit Z1C-01MI Pavillon en verre gris 36”...
  • Page 42: Garantie Limitée

    Zephyr Corporation (désigné aux présentes sous le nom de « nous ») garantit au premier acheteur (désigné aux présen- tes sous le nom de « vous » ou « votre ») de produits Zephyr (les « Produits ») que lesdits produits sont exempts de défauts de fabrication ou de main-d’œuvre selon les conditions suivantes :...

This manual is also suitable for:

Milano wall zmi-m90bg