E page F page S page APPROVED FOR RESIDENTIAL APPLIANCES FOR RESIDENTIAL USE ONLY READ AND SAVE THESE INSTRUCTIONS PLEASE READ ENTIRE INSTRUCTIONS BEFORE PROCEEDING. INSTALLATION MUST COMPLY WITH ALL LOCAL CODES. IMPORTANT: Save these Instructions for the Local Electrical Inspectors use. INSTALLER: Please leave these Instructions with this unit for the owner.
www.zephyronline.com Important safety Notice ..............4 Electrical & Installation requirements ..........5 Electrical requirements .............. 5 Before installing the hood ............5 List of Materials ................. 6 Parts supplied: ................6 Parts not supplied ..............6 Dimensions and clearances.............. 7 Installation Instructions ..............
READ AND SAVE THESE INSTRUCTIONS CAUTION: FOR GENERAL VENTILATING USE ONLY. DO NOT USE TO EXHAUST HAZARDOUS OR EXPLOSIVE MATERIALS OR VAPORS. WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: A. Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer. B.
www.zephyronline.com ELECTRICAL REQUIREMENTS Important: Observe all governing codes and ordinances. It is the customers responsibility: To contact a qualified electrical installer. To assure that the electrical installation is adequate and in conformance with National Electrical Code, ANSI/NFPA 70 ...
PARTS SUPPLIED: Blower unit housing Hood canopy Metal filter x 1 Halogen light bulb x 4 Upper and lower Duct covers x 4 Chimney structure Hardware Packet: Allen spanner x 1 Template Use, Care and Installation guide Nuts x 12 3,5x6,5 screws x 15 (11 to assemble Hood canopy to Chimney structure + 4 to fix duct covers to chimney structure and to hood canopy )
Closely follow the instructions set out in this manual. All responsibility, for any eventual inconveniences, damages or fires caused by not complying with the instructions in this manual, is declined. VENTING METHODS The hood is equipped with a transition B for discharge of fumes to the outside (Ducting version). Should it not be possible to discharge cooking fumes and vapour to the outside, the hood can be used in the Ductless (recirculating) version.
www.zephyronline.com Duct pieces Equivalent number Duct pieces Equivalent number lenght x used Total lenght x used Total 3 1/4 x 10 1 Ft. 6" Round 30 Ft. x ( Rect., wall cap straight with damper 7 Round,, 1 Ft.
1. Pre-installation calculations 2. Preparation of mounting surface Installing supports above ceiling drywall. Template Ceiling K = Kitchen Height C = Counter Height (36" standard) P = Prefered Height of Hood Bottom above counter (recommended 24-32) H = Hood height your 2"...
Page 11
www.zephyronline.com c. Install a 8 exhaust duct and extend length = S - 16 5. Note: disregard this step if is intended to install 5/8 from ceiling. Duct shall be securely fastened a remote ventilator. to joists. Do not use duct smaller than specified. Purchase and install the Integral ventilator (see paragraph Before installing the hood - Parts Attention: Duct installation is not required for non-...
8. Electrical connection Conduit WARNING Electrical Shock Hazard Warning: Turn off power circuit at the service panel before wiring this unit. 120 VAC, 15 or 20 Amp circuit required. J-Box cover ELECTRICAL GROUNDING INSTRUCTIONS THIS APPLIANCE IS FITTED WITH AN ELECTRICAL JUNCTION BOX WITH 3 WIRES, ONE OF WHICH (GREEN/YELLOW) SERVES TO GROUND THE APPLIANCE.
Page 13
www.zephyronline.com d. Fasten the canopy with 12 screws from the 12. Fix 6 nuts on the internal side of top duct covers bottom. sections (squere slots) and fix each other with 6 screws (3 per side). Rectangular FRONT slots Plan diagram FRONT sections...
Page 14
covers section (square slots - see drawings after sections with 8 screws each other (the lower step 11) and place it on the rear side of the hood on screws fix duct cover to canopy). top the canopy, cheack that it snaps with top duct covers assembly.
Page 15
www.zephyronline.com vent cover assembly. Cut the upper (wide) trim strips to length to fit the upper duct cover assembly. Assemble the upper trim strips to the upper duct cover assembly. Upper Upper Lower Lower 18. Check all light bulbs to make sure they are secure in their sockets.
1 Control panel 2 Grease filter 3 Grease filter release handle 4 Halogen lamp (position and nr. of lamps may vary) 5 Hood canopy 6 Duct cover 7 Air outlet (used for Ductless version only) CONTROLS Use the high suction speed in cases of concentrated kitchen vapours. It is recommended that the cooker hood suction is switched on for 5 minutes prior to cooking and to leave in operation during cooking and for another 15 minutes approximately after terminating cooking.
www.zephyronline.com Prior to any maintenance operation ensure that the cooker hood is disconnected from the power supply. CLEANING The cooker hood should be cleaned regularly internally and externally. For cleaning use a cloth moistened with a neutral liquid detergents. Avoid abrasive detergents. Warning: Failure to carry out the basic standards of the cleaning of the cooker hood and replacement of the filters may cause fire risks.
Issue Cause What to do After installation, the 1. The power source is not turned ON. 1. Make sure the circuit breaker and the unit doesnt work? units power is ON. 2. The power line and the cable locking 2. Check the power connection with the connector is not connecting properly.
Product damaged through negligence, misuse, abuse, accident. Improper installation and failure to follow installation instructions. When product is used commercially or other than its intended purpose. Damaged because of improper connection with equipment of other manufacturers. Repaired or modified by anyone other than Zephyrs Authorized Agents. What is Not Covered: Consumable parts such as light bulbs, filters, and fuses.