The microwave can be fitted in position A or B:
Position Niche size
W
A
560 x 550 x 380
B
560 x 500 x 380
Measurements in (mm)
INSTALLING THE APPLIANCE
1. Remove all packaging and check carefully for
any signs of damage.
2. Fit the appliance into the kitchen cupboard
slowly, and without force, until the front frame
of the oven seals against the front opening of
the cupboard.
3. Ensure the appliance is stable and not
leaning. Ensure that a 4 mm gap is kept
between the cupboard door above and the
top of the frame (see diagram).
4 mm
D
H
4 mm
4 mm
Position A
Conventional
oven
Fixing Option 1:
Fix the oven in position with the screws provided.
The fixing points are located on the top and
bottom corners of the oven.
Fixing Option 2:
Please see the template sheet supplied with this
oven.
Important!
Ensure the bottom of the oven is 85 cm or
more above the floor. It is important to
ensure that the installation of this product
conforms to the instructions in this
operation manual and the conventional
oven manufacturer's installation
instructions.