Page 1
(ver.0.0) 1 / 9 Line Scan Camera Instruction Manual Model: TL-2048UFD TAKENAKA SENSOR GROUP TAKENAKA SYSTEM CO.,LTD. □ H e a d O f f i c e 86-66 Nomizo-cho Otsuka Yamashina-ku 607-8135 Kyoto JAPAN TEL:+81-75-593-9300 FAX +81-75-593-9790 □ C a m e r a D e p t .
3 / 9 1. Outline ● CCD line scan camera with 2048 pixels of image sensor and of 40MHz data rate. ● Ω- Digital video signal (10 bit) and analog video signal (0 to 2.5V at 75 terminated) are delivered at a time as in the case of UFD series camera.
4 / 9 4. Specifications Number of pixels 2048 Pixel size 10μm × 10μm Photo array length 20.48 mm Data rate 40 MHz Scan rate 18 kHz Max. 55.5 μsec or more Line transfer pulse input Analog signal: 0 to 2.5V, 75Ω Video output Digital signal: 10bit (D0 to D9+, D0 to D9-) Sensitivity...
5 / 9 5. Camera I / O 5-1 Power source The camera is powered through 15-pin connector. Though ripple-free and stable power source is preferable, the switching supply is also employable. In general, ripple voltage of a stabilized power source is approx.35mV, and approx.120mV for a switching supply.
6 / 9 Exposure control EXP switch on the rear It can switch the exposure mode between three types of exposure modes by setting panel of the camera ① Line period exposure EXP setting N=0 Exposure during each period of EXT.SYNC ②...
Page 7
7 / 9 Internal SW configuration (A) Sectional side view PCB1-VR2 PCB2-CN6 PCB1-VR2 Anti-blooming adjustment volume PCB2-CN6 Writing connector to ALTERA's chip (B) Sectional side view PCB2-SW1 PCB1-VR1 PCB2-SW1 GAIN switch 1 to 3 of SW1 GAIN ×1 OFF OFF OFF ×2 ON OFF OFF ×3...
Page 8
8 / 9 TL-2048UFD Timing chart Line period exposure 【 】 EXP switch:0 Ext_SYNC Ext_CLK Delay time of SYNC_OUT against Ext_SYNC↑:44clk SYNC_OUT(Φ P) SYNC width:10clk CLK_OUT DATA_OUT Effective pixel start:42clk Fixed time exposure 【 】 EXP switch:1~E Ext_SYNC Ext_CLK Φ A 12clk...
9 / 9 External dimensions 88.5 68.2 VIDEO SYNC M2.6(depth6,3faces) N i k o n M o u n t Element DI GIT AL OU T POWER (27.6) F . B : 4 6 . 5 1/4"20UNC (Tripod socket hole) 2-M6 11.2 17.5 17.5...