10 XMIT TO CONFIRM
PRESS
Numbers do not match
after activating the
Zn ZT RC In: L
11 00
Note that when editing, an "s"
next to the loop number indi-
cates that the transmitter's
serial number has been
enrolled.
NOTE: Following the successful enrollment of each wireless device, remove ONE of the serial number labels from the
device and affix it in the appropriate column on the ENROLLED TRANSMITTERS worksheet of the Programming
Form; then enter the other information (zone number, zone type, loop number, etc.) relevant to that device. This
information would be useful if any troubleshooting is needed later on. The installer may want to consider leaving this
worksheet at the site (in the panel cabinet).
To Remove a Zone
To either temporarily or permanently remove a zone from the system (5800 system):
1. Enter the programming mode:
Key Installer Code + 8 + 0 + 0 and press
2. The following display appears:
S E T T O C O N F I R M ?
0 = N O 1 = Y E S
3. The following display appears:
E n t e r Z n N u m .
( 0 0 = Q u i t )
✱
Press [
Zn ZT RC In: L
10 03
✱
Press [
0 1 Z o n e T y p e
Z o n e D i s a b l e d
The prompt to confirm appears. This prompt appears only if you
asnswered "Yes" to the SET TO CONFIRM? prompt at the bottom of
✱
TO SKIP
page 16-4. To confirm, activate the loop input or button that corresponds
to this zone.
The system checks for a duplicate. If a duplicate exists, a long error beep
sounds.
Press [#] to back up and re-enter the serial and/or loop number.
If Serial or Loop
If the serial/loop number combination transmitted does not match the
serial and loop number entered, a display similar to the one below
appears. If the loop number does not match, it is also displayed.
transmitter
→
If so, activate the transmitter's loop input or button one or more times.
If a match is still not obtained (i.e., summary display does not appear),
press the [#] key twice and enter the correct loop input or, if correct, press
[#] again and then enter the correct serial number.
If the serial number transmitted matches the serial number entered, the
keypad beeps 3 times and advances to the Summary display of the next
10 RF: -
zone to be programmed.
Enter 0 for No; 1 for Yes.
0
Enter zone number to be removed. Example: 10.
1 0
] to continue.
This summary display appears.
10 RF: 1s
] to continue.
4. Enter 00. This sets the zone type to Zone Disabled.
0 0
Press [
K e y d
A 0 2 2 - 4 0 6 3
R c v d
A 0 2 2 - 4 0 6 4
✱
56.
✱
] to continue.
Section 6: Zone Programming
1
1
6–5