The PUG condensing units are cooling only models that are • TOP DISCHARGE - The warm air from the top designed specifically for use with Mitsubishi Electronics PK, mounted fan is blown up away from the structure and PC, and PL MR. SLIM indoor units of matching nominal any landscaping.
(DB) temperature using a thermometer. Refrigerant charging should only be carried out by a qualified air conditioning contractor. Table 1: SUPERHEAT VALUE INDOOR WB OUTDOOR DB°F °F 100 105 1. Evaporator Entering Air °F Mitsubishi Electronics 2003...
Page 22
To bring the tube temperature in line with the required dry bulb. value from Table 2, add refrigerant to the service port to cause the tube temperature to fall and reclaim refrigerant to cause the temperature to rise. Mitsubishi Electronics 2003...
DB (°F) WB (°F) DB (°F) WB (°F) Standard Temperature Maximum Temperature – Cooling Minimum Temperature – Maximum Humidity 1. A low ambient accessory kit is required for operation below this temperature which extends cooling operation to 25°. Mitsubishi Electronics 2003...
VAPOR OD R-22 CHARGE, OZ/FT PUG18, 24 0.14 PUG30, 36, 42 0.33 FACTORY CHARGE / ADD CHARGE ARI RATING POINT MODEL 25 FT 40 FT 55 FT 70 FT R-22 CHARGE, OZ PUG18 PUG24 PUG30 PUG36 PUG42 Mitsubishi Electronics 2003...
P8 fault. If the switch opens 3 times within a one-hour period, the outdoor unit will be “locked out” and must be serviced. Turning line voltage off and back on to the outdoor unit will reset the lockout. Mitsubishi Electronics 2003...
Page 27
LATS Open 4 Flash Sequence Low Pressure Safety Switch Open “CCH” LED indicates that the crankcase heater is energized. “2” LED indicates that the indoor unit is calling for compressor operation, 12VDC is present on control wire #2. Mitsubishi Electronics 2003...
It is important to use a back-up wrench on the liquid line base valve connections when accessing the orifice. Failure to do so could loosen the base valve connections and cause a refrigerant leak. FIELD CONNECTION INDOOR COIL LINE OUTDOOR COIL SUCTION ACCUMULATOR COMPRESSOR FIELD CONNECTION LINE COOLING CYCLE FLOW Mitsubishi Electronics 2003...
036-21534-001 Rev. B (0703) PARTS BREAKDOWN Mitsubishi Electronics 2003...
Page 31
New replacement parts shown in bold face type at the first printing of parts list dated 4/ Major components and suggested stocking items are shown with shaded item number. “<“ Across from row indicates a change in that row. --- Not applicable to specified model. Mitsubishi Electronics 2003...
Page 32
New replacement parts shown in bold face type at the first printing of parts list dated 4/ Major components and suggested stocking items are shown with shaded item number. “<“ Across from row indicates a change in that row. --- Not applicable to specified model. Mitsubishi Electronics 2003...
Low Ambient Kit 2LA08700324 All PUG Models (extends cooling operation to 25°) TO ORDER AUTHORIZED FACTORY REPLACEMENT PARTS - Contact your local Mitsubishi Electric distributor. or visit our website at www.mrslim.com for a Distributor and Dealer listing. Mitsubishi Electronics 2003...
Page 34
14 NOTES Mitsubishi Electronics 2003 036-21534-001 Rev. B (0703) Supersedes: 036-21534-001 Rev. A (0603)