free hit counter
Harman P43 Installation Manual

Harman P43 Installation Manual

Harman p43; p61a; p68 freestanding pellet stove

Advertisement

INSTALLER: Leave this manual with party responsible for use and operation.
OwNER: Retain this manual for future reference.
NOTICE: SAVE THESE INSTRUCTIONS
Model(s):
P43, P61A & P68
Freestanding Pellet Stove
!
Tested and approved for wood pellets only. Burning of
any other type of fuel voids your warranty.
!
Check building codes prior to installation.
• Installation MUST comply with local, regional, state and
national codes and regulations.
• Contact local building or fire officials about restrictions and
installation inspection requirements in your area.
1
Installation Manual
Installation and Appliance Setup
CAUTION
CAUTION
Harman® • P-Series Installation Manual_R8 • 2014 - ___ • 04/15
Please read this entire manual before
installation and use of this pellet fuel-
burning room heater.
Failure to follow these instructions could
result in property damage, bodily injury
or even death.
• Do not store or use gasoline or other flammable vapors
and liquids in the vicinity of this or any other appliance.
• Do not overfire - If any external part starts to glow, you
are overfiring. Reduce feed rate. Overfiring will void
your warranty.
• Comply with all minimum clearances to combustibles
as specified. Failure to comply may cause house fire.
wARNING
HOT SURFACES!
Glass and other surfaces are hot during
operation AND cool down.
Hot glass will cause burns.
• Do not touch glass until it is cooled
• NEVER allow children to touch glass
• Keep children away
• CAREFULLY SUPERVISE children in same room as
stove.
• Alert children and adults to hazards of high temperatures.
High temperatures may ignite clothing or other
flammable materials.
• Keep clothing, furniture, draperies and other flammable
materials away.
NOTE
To obtain a French translation of this manual, please
contact your dealer or visit www.harmanstoves.com
Pour obtenir une traduction française de ce manuel, s'il
vous plaît contacter votre revendeur ou visitez www.
harmanstoves.com
wARNING
3-90-436168i

Advertisement

Table of Contents
loading

Summary of Contents for Harman P43

  • Page 1 To obtain a French translation of this manual, please Check building codes prior to installation. contact your dealer or visit www.harmanstoves.com • Installation MUST comply with local, regional, state and national codes and regulations. Pour obtenir une traduction française de ce manuel, s’il • Contact local building or fire officials about restrictions and vous plaît contacter votre revendeur ou visitez www. installation inspection requirements in your area. harmanstoves.com Harman® • P-Series Installation Manual_R8 • 2014 - ___ • 04/15 3-90-436168i...
  • Page 2: Table Of Contents

    I. Fire Safety ........21 J. Inspect Appliance & Components ....21 Harman® • P-Series Installation Manual_R8 • 2014 - ___ • 04/15 3-90-436168i...
  • Page 3: Installation Standard Work Checklist

    120VAC unswitched power provided to the appliance. ________________________________ Appliance Setup Section 5 (Pg. 21-22) All packaging and protective materials are removed ________________________________ Accessories installed properly ________________________________ Manual bag and all it’s contents are removed from inside the appliance and given to party responsible for use and operation ________________________________ Started appliance and verified that all motors and blowers operate as they should. ________________________________ Hearth and Home Technologies recommends the following: Photographing the installation and copying this checklist for your file. This checklist remain visible at all times on the appliance until the installation is complete. Comments: Further description of the issues, who is responsible (Installer/Builder/Other Trades, etc.) and corrective action needed __________________________________________________________________________________________ _________________________________________________________________________________________________ _________________________________________________________________________________________________ Comments communicated to party responsible____________________ by ________________________ on __________ (Builder / Gen Contractor) (Installer) (Date) Harman® • P-Series Installation Manual_R8 • 2014 - ___ • 04/15 3-90-436168i...
  • Page 4: Product Specific And Important Safety Information

    In the absence of local codes you must comply with the ASTM E1509-2004, ULC-S627-00, ULC/ORD-C- 1482-M1990, (UM) 84-HUD The P43, P61A and P68 are Certified to  comply with 2015 particulate emission standards. Not approved for sale after May 15, 2020. Harman® • P-Series Installation Manual_R8 • 2014 - ___ • 04/15 3-90-436168i...
  • Page 5: Btu Specifications

    ****Based on the maximum feed rate per hour multiplied by approximately 8,600 BTU’s which is the average BTU’s from Harman is a registered trademark of Hearth & Home a pound of pellets. ® Technologies. This wood heater needs periodic inspection and repair for proper operation. It is against federal regulations to operate this wood heater in a manner inconsistent with operating instructions in this manual. Harman® • P-Series Installation Manual_R8 • 2014 - ___ • 04/15 3-90-436168i...
  • Page 6: Getting Started

    • Avoid outside wall in cooler climates Windward Leeward Multi-level Roofs Recommended: NOT recommended: Outside Air Intake Outside Air Intake on windward side on leeward side Figure 2.1 Harman® • P-Series Installation Manual_R8 • 2014 - ___ • 04/15 3-90-436168i...
  • Page 7: Tools And Supplies Needed

    RISk OF FIRE OR ExPlOSION! Damaged parts Do NOT use makeshift compromises when installing this could impair safe operation. DO NOT install damaged, appliance, serious consequences may result. incomplete or substitute components. Keep appliance dry. Harman® • P-Series Installation Manual_R8 • 2014 - ___ • 04/15 3-90-436168i...
  • Page 8: Appliance Dimension Diagram

    P61A Freestanding Pellet Stove Outside Outside Air Intake Air Intake 5 1/8" 5 1/8" 22" 23 1/2" 20 3/4" P68 Freestanding Pellet Stove Outside Air Intake 5 1/4" 23-1/2” Figure 3.1 Harman® • P-Series Installation Manual_R8 • 2014 - ___ • 04/15 3-90-436168i...
  • Page 9: Clearances To Combustibles

    P43 Freestanding Pellet Stove 2"(51mm) 2"(51mm) 14" (355mm) with *10" (254mm) with side shields side shields 20" (508mm) *16" (406mm) without side shields without side shields *10" (254mm) 14" (355mm) *16" (406mm) 20" (508mm) 36"(914mm) 36"(914mm) 9"(228mm) 9"(228mm)- 13"(330mm) 9"(228mm)With Side Shields 9" (228mm) With or Without Side Shields 13"(330mm) Without Side Shields Figure 3.2 Harman® • P-Series Installation Manual_R8 • 2014 - ___ • 04/15 3-90-436168i...
  • Page 10: Floor Protection

    Minimum size floor protection for a corner installation CANADA hearth pad is 36” x 36” (USA ONLY). NOTE: Floor protector WIll NOT touch the wall. loor protector Figure 3.3 Harman® • P-Series Installation Manual_R8 • 2014 - ___ • 04/15 3-90-436168i...
  • Page 11: Termination Location And Vent Information

    Keep combustible materials (such as grass, leaves, etc.) at least 3 feet away from the flue outlet on the outside of the building. 3 Ft. to Combustibles Figure 4.2 Harman® • P-Series Installation Manual_R8 • 2014 - ___ • 04/15 3-90-436168i...
  • Page 12 Kaowool, mineral wool or an equivalent non- combustible insulation is recommended to be installed on top of the sealing plate to reduce the possibility of condensation. The connector pipe should extend through the smoke chamber to the base or into the first flue tile. Seal pipe joints with silicone or aluminum tape in addition to the sealing system used by the manufacturer. Be sure to design the venting so that it can be easily cleaned. Figure 4.4 Harman® • P-Series Installation Manual_R8 • 2014 - ___ • 04/15 3-90-436168i...
  • Page 13 #6 Installing into an existing chimney (Figure 4.6) w/Full liner This method provides excellent venting for normal operation. This method also provides natural draft in the event of a power failure. In some places in the US and Canada it is required that the vent pipe extend all the way to the top of the chimney. Seal pipe joints with silicone or aluminum tape in addition to the sealing system used by the manufacturer. The pipe or liner inside the chimney should be 4" diameter. In this method a cap should also be installed on the chimney to keep out rain. Figure 4.6 Harman® • P-Series Installation Manual_R8 • 2014 - ___ • 04/15 3-90-436168i...
  • Page 14 Through the ceiling vent, follow PL vent manufacturers clearance to combustible materials such as shrubbery, recommendations when using wall and ceiling pass through. mulch or tall grasses. Seal pipe joints with silicone or aluminum tape in addition to the sealing system used by the manufacturer. Do not place joints within wall pass-through. min. wall to outlet 12" Figure 4.9 Harman® • P-Series Installation Manual_R8 • 2014 - ___ • 04/15 3-90-436168i...
  • Page 15: Chimney Diagram

    CAN/CSA-B365. (if in Canada) G. The clearance to an inside corner is 12". H. A vent must not be installed within 3 feet (90 cm) above a gas meter/regulator assembly when measured from the horizontal center-line of the regulator. Harman® • P-Series Installation Manual_R8 • 2014 - ___ • 04/15 3-90-436168i...
  • Page 16: Venting & Use Of Elbows

    3” vent pipe should not be used in this • Vertical Pipe or Liner: ½ EVL Unit installation. However, since 4” pipe can support an EVL up to 30, the use of 4” pipe would create a satisfactory • Horizontal Pipe or liner: 1 EVL Unit installation. The total allowable equivalent vent length is: • 20 EVL for 3” pellet vent pipe or liner • 30 EVL for 4” pellet vent pipe or liner Due to the potential for fly ash accumulation in horizontal venting sections, the maximum permissible horizontal venting length is: • 4 ft. for 3” & 4” pellet vent pipe. Harman® • P-Series Installation Manual_R8 • 2014 - ___ • 04/15 3-90-436168i...
  • Page 17 Increaser Part #3PVPX4ADHB are highly recommended to be installed on the starter collar to insure a proper pipe connection to the unit. • INSTALL VENT AT CLEARANCES SPECIFIED BY THE VENT MANUFACTURER • Use silicone to create an effective vapor barrier at the location where the chimney or outside air ducting passes through to the exterior of the structure Harman® • P-Series Installation Manual_R8 • 2014 - ___ • 04/15 3-90-436168i...
  • Page 18: Outside Air

    Use silicone to create an effective vapor barrier at the location where the chimney or outside air ducting passes through to the exterior of the structure. Figure 4.14 Harman® • P-Series Installation Manual_R8 • 2014 - ___ • 04/15 3-90-436168i...
  • Page 19: Locating Your Appliance And Chimney

    Minimum Vacuum Requirements: .35 - .55 • Downdrafts Prior to installing the flue pipe, connect a draft meter. (The • Tight sealing construction of the structure draft meter must have a minimum range of 0 - .5”) Record the first reading. Connect flue pipe to stove and be sure all doors • Mechanical exhausting devices and windows in the home are closed. Record the second draft reading _______. If the second reading is more than .05” lower than the first reading, check for possible restrictions or the need for outside air. For more information on the draft test procedure, refer to Page 21 Harman® • P-Series Installation Manual_R8 • 2014 - ___ • 04/15 3-90-436168i...
  • Page 20: Avoiding Smoke & Odors

    House demand may consume the air needed for the appliance. It may be necessary to add additional ventilation to the space in which the pellet appliance is located. Consult with your local HVAC professional to determine the ventilation demands for your house. Vent Pipe Be sure to use approved pellet vent pipe wall and ceiling pass- through fittings to go through combustible walls and ceilings. Be sure to use a starting collar to attach the venting system to the stove. The starting collar must be secured to the flue stub with at least three screws, and sealed with high temp silicone caulking. 4" stainless steel flex vent piping is only allowed for use in masonry fireplaces and chimneys or factory built wood burning fireplaces with class A metal chimneys. Pellet venting pipe (also known as Type L vent) is constructed of two layers with air space between the layers. This air space acts as an insulator and reduces the outside surface temperature to allow a clearance to combustibles of only 1 inch. The sections of pipe lock together to form an air tight seal in most cases; however, in some cases a perfect seal is not achieved. For this reason and the fact that the P-Series operates with a positive vent pressure, we specify that the joints also be sealed with silicone. Where passing through an exterior wall or roof, be sure to use the appropriate pass-through device providing an adequate vapor barrier. Venting manufacturers generally provide these pass-through devices. Harman® • P-Series Installation Manual_R8 • 2014 - ___ • 04/15 3-90-436168i...
  • Page 21: Fire Safety

    MINIMUM LOw BURN RATE THAT MUST NOT BE ALTERED. IT IS AGAINST FEDERAL REGULATIONS TO ALTER THIS SETTING OR OTHERwISE OPERATE THIS wOOD HEATER IN A MANNER INCONSISTENT wITH OPERATING INSTRUCTIONS IN THIS MANUAL. Harman® • P-Series Installation Manual_R8 • 2014 - ___ • 04/15 3-90-436168i...
  • Page 22: Appliance Setup

    If needed, install the (2) 5/16-18 X 3/4” leveling bolts located in the hardware kit. Figure 5.1. Leveling Bolt Leveling Bolt Shipping Bolts C. Firebrick Note: These same holes are used for securing the stove in mobile home The P43 Pellet Stove has a single (1) firebrick that gets Figure 5.1 installation. installed horizontally on the angle bracket above the burnpot. The P61A and P68 have three (3) firebrick that get installed vertically on the angle bracket. Figure 5.2. D. Flame Guide 1 Firebrick P43 Pellet Stove Install the cast iron flame guide on top of the burn pot. Make...
  • Page 23: Room Sensor

    Figure 5.5 Connect the power cord to a 120 VAC, 60 Hz grounded receptacle. (A surge protector is recommended to protect the circuit board.) Also be sure that the polarity of the outlet that the stove is plugged into is correct. Figure 5.4 Harman® • P-Series Installation Manual_R8 • 2014 - ___ • 04/15 3-90-436168i...
  • Page 24: Reference Materials

    THE STOVE FOR HIGHER HEAT OUTPUT MAY CAUSE DAMAGE TO THE STOVE AND COULD RESULT IN A HOUSE FIRE. USE ONLY APPROVED FUELS AND FOLLOw ONLY THESE OPERATION GUIDELINES. Harman® • P-Series Installation Manual_R8 • 2014 - ___ • 04/15 3-90-436168i...
  • Page 25: Wiring Diagram

    B. wiring Diagram Harman® • P-Series Installation Manual_R8 • 2014 - ___ • 04/15 3-90-436168i...
  • Page 26 352 Mountain House Road, Halifax, PA 17032 www.harmanstoves.com Please contact your Harman dealer with any questions or concerns. ® For the location of your nearest Harman dealer, ® please visit www.harmanstoves.com. Printed in U.S.A Harman® • P-Series Installation Manual_R8 • 2014 - ___ • 04/15 3-90-436168i...

This manual is also suitable for:

P61aP68