7. Remove two glass tapes securing the LCD cable and disconnect the LCD cable from
the connector on the LCD unit.
CAUTION: When removing the LCD cable, be careful not to damage the connector.
8. Remove the following screws and LCD unit.
•
M2×3C
CAUTION: When lifting up the top of the LCD unit, hold the corners of the LCD unit.
The top edge of LCD unit is sensitive area.
Glass tape
LCD unit
M2×3C BIND
TECRA A9/TECRA S5/TECRA P5/Satellite Pro S200 Maintenance Manual (960-633) [CONFIDENTIAL] 4-77
BIND screw
Figure 4-48 Removing the LCD unit
4 Replacement Procedures
×4
LCD cable
M2×3C BIND