7-3 Gain control

7-3-1 ADC gain setting

Logrl=N

7-3-2 Analog gain setting

again=N
It is recommended to use "7-3-1 ADC gain setting", as the four-fold value of Analog gain is too
sensitive and is more likely to worsen the standard deviation.
It is recommended to make Flat field correction again after gain changing.
Do not use the gain command "gain position" which has been used in the conventional product.
Sets the ADC gain
Initial value =40
The relationship between the setting value and ADC gain is shown in the
following chart.
Vertical axis: Scale factor (1 at logrl=40)
Horizontal axis: Setting value N
Sets the Analog gain of the camera.
0:
one-fold
1:
four-fold
N : 0 to 255