free hit counter
Daikin FTS50BVMB Operation Manual
Hide thumbs Also See for FTS50BVMB:

Advertisement

DAIKIN ROOM AIR CONDITIONER
Operation Manual
MODELS
FTS50BVMB
FTS60BVMB
FTYS50BVMB
FTYS60BVMB
English
Deutsch
Français
Nederlands
Español
Italiano
ÅëëçíéêÜ
Portugues
Russian

Advertisement

Table of Contents
loading

Summary of Contents for Daikin FTS50BVMB

  • Page 1 DAIKIN ROOM AIR CONDITIONER MODELS FTS50BVMB FTYS50BVMB Operation Manual FTS60BVMB FTYS60BVMB English Deutsch Français Nederlands Español Italiano ÅëëçíéêÜ Portugues Russian...
  • Page 2 3P098586-2 M02B052 (0211) HT...
  • Page 3: Table Of Contents

    CONTENTS READ BEFORE OPERATION Safety precautions ......... 2 Names of parts..........4 Preparation Before Operation ......7 OPERATION AUTO · DRY · COOL · HEAT · FAN Operation ............. 10 Adjusting the Air Flow Direction ....12 POWERFUL Operation ........ 13 TIMER Operation .........
  • Page 4: Safety Precautions

    • Do not attempt to repair, relocate, modify or reinstall the air conditioner by yourself. Incorrect work will cause electric shocks, fire etc. For repairs and reinstallation, consult your Daikin dealer for advice and information. • The refrigerant used in the air conditioner is safe. Although leaks should not occur, if for some reason any refrigerant happens to leak into the room, make sure it does not come in contact with any flame as of gas heaters, kerosene heaters or gas range.
  • Page 5: Installation Site

    • Do not stand or sit on the outdoor unit. Do not place any object on the unit to avoid injury, do not remove the fan guard. • Do not place anything under the indoor or outdoor unit that must be kept away from moisture. In certain conditions, moisture in the air may condense and drip.
  • Page 6: Names Of Parts

    Names of parts I Indoor Unit The illustration shows a 50-class unit I Main unit control panel...
  • Page 7: I Outdoor Unit

    I Outdoor Unit I I I I Indoor Unit 1. Air filter • Push this switch once to start operation. Push once again to stop it. 2. Photocatalytic deodorizing filter or • The operation mode refer to the following table. Air purifying filter: •...
  • Page 8: Remote Controller

    I Remote Controller ON/OFF TEMP POWERFUL MODE SWING CANCEL TIMER < > ARC433A23, A24 1. Signal transmitter: 7. FAN setting button: • It sends signals to the indoor unit. • It selects the air flow rate setting. 2. Display: 8. SWING button: (page 12.) •...
  • Page 9: Preparation Before Operation

    Preparation Before Operation I To set the batteries Position + and – correctly! 1. Press with a finger and slide the front cover to take it off. 2. Set two dry batteries (AAA). 3. Set the front cover as before. ATTENTION I I I I About batteries •...
  • Page 10 Preparation Before Operation I To operate the remote controller • To use the remote controller, aim the transmitter at the indoor unit. If there is anything to block signals between the unit and the remote controller, such as a curtain, the unit will not operate.
  • Page 11: Operation

    I To set the clock 1. Press “CLOCK button”. is displayed. blinks. 2. Press “TIMER setting button” to set the clock to the present time. ON/OFF Holding down “ ” or “ ” button rap- TEMP POWERFUL idly increases or decreases the time dis- play.
  • Page 12: Auto · Dry · Cool · Heat · Fan Operation

    OPERATION AUTO · DRY · COOL · HEAT · FAN Operation The air conditioner operates with the operation mode of your choice. From the next time on, the air conditioner will operate with the same operation mode. I To start operation 1.
  • Page 13 I To change the air flow rate setting 5. Press “FAN setting button”. DRY mode AUTO or HEAT or COOL or FAN mode Five levels of air flow rate setting from “ ” to “ ” plus “ ” are available. The air flow rate setting is not variable.
  • Page 14: Adjusting The Air Flow Direction

    Adjusting the Air Flow Direction You can adjust the air flow direction to increase your com- fort. I To adjust the horizontal blade (flap) 1. Press “SWING button”. The display will light up and the flap will begin to swing. ON/OFF 2.
  • Page 15: Powerful Operation

    POWERFUL Operation POWERFUL operation quickly maximizes the cooling (heating) effect in any operation mode. You can get the maximum capacity. I To start POWERFUL operation 1. Press “POWERFUL button”. • POWERFUL operation ends in 20 minutes. Then the system automatically operates ON/OFF again with the settings which were used before POWERFUL operation.
  • Page 16: Timer Operation

    TIMER Operation Timer functions are useful for automatically switching the air conditioner on or off at night or in the morning. You can also use OFF TIMER and ON TIMER in combination. I To use OFF TIMER opera- tion • Check that the clock is correct. If not, set the clock to the present time.
  • Page 17: To Combine On/Off Timers

    I To use ON TIMER operation • Check that the clock is correct. If not, set the clock to the present time (page 9.). 1. Press “ON TIMER button”. is displayed. blinks. 2. Press “TIMER Setting button” until the time setting reaches the point you like.
  • Page 18: Care And Cleaning

    CARE Care and Cleaning Before cleaning, be sure to stop the operation and CAUTION turn the breaker OFF. Units I Indoor unit, Outdoor unit and Remote controller 1. Wipe them with dry soft cloth. I Front grille 1. Open the front grille. •...
  • Page 19: I Air Filter

    Filters 1. Open the front grille. (page 16) 2. Pull out the air filters. • Push a little upwards the tab at the center of each air filter, then pull it down. 3. Take off the air purify- tabs (3 tabs at top) ing filter with photo- catalytic deodorizing function.
  • Page 20: Before A Long Idle Period

    Check Check that the base, stand and other fittings of the outdoor unit are not decayed or corroded. Check that nothing blocks the air inlets and the outlets of the indoor unit and the outdoor unit. Check that the earth wire is not disconnected or broken. Check that the drain comes smoothly out of the drain hose during COOL or DRY operation.
  • Page 21: Trouble Shooting

    TROUBLE SHOOTING Trouble Shooting These cases are not troubles. The following cases are not air conditioner troubles but have some reasons. You may just continue using it. Case Explanation Operation does not start soon. • This is to protect the air conditioner. •...
  • Page 22: Check Again

    Check again. Please check again before calling a repair person. Case Check The air conditioner does not • Hasn’t a breaker turned OFF or a fuse blown? operate. • Isn’t it a power failure? (OPERATION lamp is off) • Are batteries set in the remote controller? •...
  • Page 23: Call The Service Shop Immediately

    Call the service shop immediately. WARNING I I I I When an abnormality (such as a burning smell) occurs, stop operation and turn the breaker OFF. Continued operation in an abnormal condition may result in troubles, electric shocks or fire. Consult the service shop where you bought the air conditioner.
  • Page 24: Fault Diagnosis

    Fault diagnosis FAULT DIAGNOSIS BY REMOTE CONTROLLER In the ARC433A series, the temperature display sections on the main unit indicate corresponding codes. “ ” 1. When the TIMER CANCEL button is held down for 5 seconds, a indication flashes on the temperature display section.