  • Page 3: Table Of Contents

    Content 1. Product Overview ........4 1.1 Components and Associated Products  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  6  ...
  • Page 4: Product Overview

    ® Helios IP Uni is very easy to install. All you have to do is connect the system into your LAN via a network cable and feed it from a 12 V power supply or your PoE supporting LAN.
  • Page 5: Advantages Of Use

    Integrated electronic lock switches with wide setting options LAN (PoE) or external 12 V power supply Configuration via web interface or dedicated PC application SIP 2.0 support HTTP server for configuration SNTP client for time synchronisation with server ® TELEKOMUNIKACE a.s., www.2n.cz...
  • Page 6: Components And Associated Products

    9153102 1 button 2 buttons 1 button, pictograms ® Helios IP Uni is designed for outdoor applications and requires no additional roof. ® Helios IP Uni units can be flush mounted without requiring any additional accessories. Use the appropriate mounting box (see below) for wall (surface) mounting.
  • Page 7: Voip Telephones

    91341481E 91378100E Part No. Adapter 12 V / 2 A 932928E Part No. A stabilised power supply has to be used if the 12 V transformer 91378100US Ethernet (PoE) power supply is not available. PoE injector ® TELEKOMUNIKACE a.s., www.2n.cz...
  • Page 8: Additional Modules

    Additional Modules Part No. 9159010 Part No. 9137410E Security Relay External IP relay ® TELEKOMUNIKACE a.s., www.2n.cz...
  • Page 9: Terms And Symbols

    Warning Always abide by this information to prevent damage to the device. Caution Important information for system functionality. Useful information for quick and efficient functionality. Note Routines or advice for efficient use of the device. ® TELEKOMUNIKACE a.s., www.2n.cz...
  • Page 10: Description And Installation

    2. Description and Installation Here is what you can find in this section: 2.1 Before You Start 2.2 Mechanical Installation 2.3 Electric Installation 2.4 Button Tags ® TELEKOMUNIKACE a.s., www.2n.cz...
  • Page 11: Before You Start

    2.1 Before You Start Product Completeness Check ® Before you start please check the contents of your Helios IP Uni delivery: ® 1× 2N Helios IP Uni 1× Torx 10 / Torx 20 double-ended wrench ® 1× Helios IP Uni Installation Manual 1×...
  • Page 12: Mechanical Installation

    Flush mounting – classic bricks (including hollow bricks, thermally insulated walls, etc.) What you need: A properly cut hole Plaster, mounting glue, mounting foam or mortar as necessary Flush mounting – plasterboard What you need: Just a properly cut hole ® TELEKOMUNIKACE a.s., www.2n.cz...
  • Page 13: Wall Mounting

    Caution ® Stainless steel screws are used for the Helios IP Uni assembly. Other screws than stainless steel ones corrode soon and may aesthetically deteriorate the surrounding environment! Having removed the front panel, make sure that no dirt gets inside the product (especially onto the sealing surface).
  • Page 14 We do not recommend you to insert the button tags now. Replace the stainless steel front panel fixing it with the stainless steel screws you unscrewed in step 4 above. ® TELEKOMUNIKACE a.s., www.2n.cz...
  • Page 15 Check the plasterboard wall and room interior pressure values (caused, e.g., by overpressure ventilation). If the difference between the values is too great, separate the intercom using, for example, the mounting box enclosed and seal the cable passage to avoid loudspeaker damage. ® TELEKOMUNIKACE a.s., www.2n.cz...
  • Page 16 Wall Mounting Use the wall (surface) mounting box, part No. 9153003 , and follow the instructions enclosed. ® TELEKOMUNIKACE a.s., www.2n.cz...
  • Page 17: Electric Installation

    Auto-MDIX function and so both the straight and crossed cable versions can be used External Power Supply Connection ® Helios IP Uni can be fed either from an external 12 V / 2 A DC power supply or from the LAN equipped with the PoE 802.3af supporting network elements. ®...
  • Page 18: External Power Supply

    PoE Supply ® Helios IP Uni is compatible with the PoE 802.3af (Class 0 – 12,95 W) technology and can be supplied directly from the LAN via compatible network elements. If your ®...
  • Page 19: Button Tags

    Tag Inserting/Replacing Instructions ® Helios IP Uni provides an intuitive, easy access to the name plates. The tags are easy to insert and replace even without a manual. You need not remove the front panel and thus are not exposed to the risk of loss of components while replacing the tags.
  • Page 20: Function And Use

    3. Function and Use ® In this section we describe the basic and extending functions of the 2N Helios IP product. Here is what you can find in this section: 3.1 Configuration 3.2 Control 3.3 Maintenance ® TELEKOMUNIKACE a.s., www.2n.cz...
  • Page 21: Configuration

    3.1 Configuration ® Helios IP Uni Use a PC equipped with any web browser to configure: Launch your web browser (Internet Explorer, Firefox, etc.). Enter the IP address of your intercom (http://192.168.1.100/, e.g.). Log in using the Admin user name and password.
  • Page 22 Wait for the second sound signal Press the quick dial button 5 times. ® Helios IP Uni will read its IP address. If the address is 0.0.0.0, it means that the intercom has not obtained the IP address from the DHCP server.
  • Page 23 The 15 times 1 sequence must be entered within 30 seconds after the first sound signal for security reasons. The inter-digit delay may be 2 s at most. The static IP address mode will be switched into the dynamic IP address mode and vice versa upon restart. ® TELEKOMUNIKACE a.s., www.2n.cz...
  • Page 24: Control

    3.2 Control ® This subsection describes how to control Helios IP Uni when viewed by an external user. Speed Dial Buttons Press the speed dial buttons on the basic unit to make quick dialling for the first 1 or 2 (depending on the model type) in the telephone directory.
  • Page 25: Maintenance

    3.3 Maintenance Cleaning ® If used frequently, Helios IP Uni gets dirty. To clean it, use a piece of soft cloth moistened with clean water. We recommend you to obey the following principles while cleaning: Never use aggressive detergents (such as abrasives or strong disinfectants).
  • Page 26: Technical Parameters

    Power supply: 12 V ± 15 % / 2 A DC or PoE PoE: PoE 802.3af (Class 0 – 12.95 W) LAN: 10/100BASE-TX s Auto-MDIX, RJ-45 Recommended cabling: Cat-5e or higher Passive switch: NO and NC contacts, up to 30 V / 1 A AC/DC ® TELEKOMUNIKACE a.s., www.2n.cz...
  • Page 27 39 mm × × 47 mm with flush mounting box × × 57 mm for wall mounting Weight Product net weight: 500 g Mounting box: 135 g Total weight incl. package: 800 g Covering leve: IP54 ® TELEKOMUNIKACE a.s., www.2n.cz...
  • Page 28: Supplementary Information

    5. Supplementary Information Here is what you can find in this section: 5.1 Troubleshooting 5.2 Directives, Laws and Regulations 5.3 General Instructions and Cautions ® TELEKOMUNIKACE a.s., www.2n.cz...
  • Page 29: Troubleshooting

    5.1 Troubleshooting For the most frequently asked questions refer to faq.2n.cz ® TELEKOMUNIKACE a.s., www.2n.cz...
  • Page 30: Directives, Laws And Regulations

    5.2 Directives, Laws and Regulations Europe ® Helios IP Uni conforms to the following directives and regulations: Directive 1999/5/EC of the European Parliament and of the Council, of 9 March 1999 – on radio equipment and telecommunications terminal equipment and the mutual...
  • Page 31 Consult the dealer or an experienced radio/TV technician for help. Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment. ® TELEKOMUNIKACE a.s., www.2n.cz...
  • Page 32: General Instructions And Cautions

    The manufacturer also assumes no responsibility for additional costs incurred by the consumer as a result of making calls using a line with an increased tariff. ® TELEKOMUNIKACE a.s., www.2n.cz...
  • Page 33: Electric Waste And Used Battery Pack Handling

    Make sure that the devices to be disposed of are complete. Do not throw battery packs into fire. Battery packs may not be taken into parts or short-circuited either. ® TELEKOMUNIKACE a.s., www.2n.cz...
  • Page 34 2N TELEKOMUNIKACE a.s. Modřanská 621, 143 01 Prague 4, Czech Republic Phone: +420 261 301 500, Fax: +420 261 301 599 E-mail: sales@2n.cz Web: www.2n.cz EN1812_v2.1 ® TELEKOMUNIKACE a.s., www.2n.cz...