Summary of Contents for Accurate Technology Digi Scale Model 10

  • Page 1 Digi Scale ™ User Manual for: Digi Scale Model 10 & Model 20 and all products with a Digi (white) Digital Readout Firmware version P1.040 & Higher...
  • Page 2 1 year commencing from the date of original purchase. Upon notification of a defect, Accurate Technology, Inc., shall have the option to repair or replace any defective part. Such services shall be the customer's sole and exclusive remedy. Expenses incidental to repair, maintenance, or replacement under warranty, including those for labor and material, shall be borne by Accurate Technology, Inc.
  • Page 3: Table Of Contents

    +, 0, and – Keys.......................... 11 Changing Resolution ........................11 Incremental Measurements ......................11 Lock Mode ..........................11 Reverse Scaling .......................... 12 Changing the Batteries ....................... 12 Jumpers ............................. 13 Frequently Asked Questions ....................... 14 Accurate Technology Digi Scale Page 3 of 17...
  • Page 4: General Information

    It is, however, well suited for most general purpose measuring applications requiring digital precision, low cost, battery power, and reliable operation. For more demanding applications Accurate Technology ProScale™ ABS should be considered. Some differences are: Feature...
  • Page 5: Digi Scale-10

    Note: If you ordered a Digi-Kit” product that contains instructions for installation on or for a specific product, (ie Digi Fence or Digi Stop) follow those installation instructions rather than the instructions presented here. Accurate Technology Digi Scale Page 5 of 17...
  • Page 6 3. Note the orientation of the Encoder. When the side with two screw holes is on the right, moving the scale up produces positive readings and moving the scale down produces negative readings. Scale: Attached to moving part Encoder: Attach to stationary Read- head Digital Readout Accurate Technology Digi Scale Page 6 of 17...
  • Page 7 Encoder do not get damaged. (A slight “wiggling” motion when installing the scale into the Encoder will simplify the process.) Note: If your application requires a scale of a different length, see SHORTENING SCALES. Accurate Technology Digi Scale Page 7 of 17...
  • Page 8: Shortening Scales

    3. Use a file or sanding tool to chamfer the cut end to approximately the specifications shown in the illustration. 4. Remove all burrs. 5. Test the shortened scale by sliding a Encoder on. There should not be any binding. .07” (2mm) .25” (6mm) Wires Wires Accurate Technology Digi Scale Page 8 of 17...
  • Page 9: Digi Scale-20

    If they do, they will interfere with the Encoder. Check that the scale is properly aligned with the direction of motion of the moving part. Accurate Technology Digi Scale Page 9 of 17...
  • Page 10 ( .8 3 " ) 3 3 . 0 m m ( 1 . 3 " ) M o d e l 2 0 S c a le Guide Clip Pressure/Spacing (End View) Accurate Technology Digi Scale Page 10 of 17...
  • Page 11: Readout Keys

    For the best resolution switch to a decimal mode. * A measurement system that measures length in inches, feet, yards, and miles; capacity in cups, pints, quarts, and gallons; weight in ounces, pounds, and tons; and temperature in degrees Fahrenheit. Accurate Technology Digi Scale Page 11 of 17...
  • Page 12: 0, And - Keys

    MODE key. measurement units (in or mm) on the LCD display will blink when the Readout is in lock mode, and the +, - keys will not change the displayed position. Accurate Technology Digi Scale Page 12 of 17...
  • Page 13: Reverse Scaling

    DO NOT BEND BATTERY CLIPS! THESE CLIPS ARE DESIGNED TO BE LOOSE WHEN THE CASE IS OPEN AND WILL COMPRESS AND SECURE THE BATTERIES IN PLACE WHEN THE CASES ARE SCREWED TOGETHER. Accurate Technology Digi Scale Page 13 of 17...
  • Page 14: Jumpers

    Changes the direction of readings. Resolution Position A: .001in / .01mm (high resolution) Position B: .01in / .1mm. (normal resolution) fractions remain the same in both settings (1/16, 1/32, 164) FACTORY USE ONLY Accurate Technology Digi Scale Page 14 of 17...
  • Page 15: Frequently Asked Questions

    The readings are “backwards”? You can change the “scaling” direction of the system by: 1. Reversing the orientation of the Encoder on the Scale 2. Changing the position of Jumper JP1 on the circuit board Accurate Technology Digi Scale Page 15 of 17...
  • Page 16 Accurate Technology Digi Scale Page 16 of 17...
  • Page 17 Please register your system at http://www.proscale.com/registration.htm Accurate Technology, Inc. 270 Rutledge Rd. Unit E Fletcher, NC 28732 USA 800 233-0580 • 828-654-7920 Fax 828-654-8824 www.digi-kit.com customerservice@accurate-technology.com This manual is available online at www.digi-kit.com Accurate Technology Digi Scale Page 17 of 17...

This manual is also suitable for:

Digi scale model 20