free hit counter

Sip Transport; Sip Server Type; Sip Session Timer Enabled - Siemens optiPoint 410 S Administrator's Manual

Hide thumbs Also See for optiPoint 410 S:
Table of Contents

Advertisement

xml_03.fm
XML Overview
Administration Tags
3.3.3.16

SIP transport

Parameter
sip-transport
Index
Value
0, 1, 2
Example
<Item name="sip-transport">0</Item>
Notes
e164, must be configured in the HiPath 8000 (SMC) Config Portal
3.3.3.17

SIP server type

Parameter
server-type
Index
Value
1, 2, 3, 4
Example
<Item name="server-type">2</Item>
Notes
e164
3.3.3.18

SIP session timer enabled

Parameter
session-timer
Index
Value
true, false
Example
<Item name="session-timer">false</Item>
Notes
e164
3-14
WEB
Transport protocol
0=UDP
1=TCP
2=TLS
WEB
SIP server type
1=HiQ8000
2=Broadsoft
3=Sylantro
4=other
WEB
Session timer on or off
A31003-2056-X619-1-76A9, March 25 2006