Glance
Installation guide
ENG
ENG

Advertisement

Table of Contents
loading

Summary of Contents for Faber Glance

  • Page 1 Glance Installation guide...
  • Page 2 1 < < < <...
  • Page 3 2 < < < <...
  • Page 4 ±110mm 3 < < < <...
  • Page 5: Table Of Contents

    Placing the appliance................ 9 Mounting the smoke emission outlet materials ........10 Building a chimney breast..............10 Chimney breast ................10 Glance Frameless ................11 Glance Framed ................11 removing the glass................. 11 Placing the decorative material..............12 Imitation logs ................12 Pebbles ..................
  • Page 6 11.2 Sample computations............... 17 Table ..................... 18 Technical data .................. 19 Dimension of the appliance ..............20 Dimension of the appliance with frame ............ 21 Ventilation Grills ................22 Dimension Service Hatch..............23 5 < < < <...
  • Page 7: Introduction

    1 Introduction The appliance can only be installed by a competent person in accordance with the Gas Safety. We urgently advise you to read this installation manual properly. This appliance complies with the guidelines for European gas appliances (Gas Appliances Directive) and bears the CE mark.
  • Page 8: Installation Requirements

    The false chimney breast and its construction may not rest on the appliance Requirements flue system and outlets  You should always make use of the materials prescribed by Faber International Ltd. Only by using these materials can Faber International Ltd. guarantee a proper functioning.
  • Page 9: Terminals

    through combustible wall or ceiling constructions. And observe sufficient distance.  Make sure that the concentric flue materials are bracketed every 2 metres when they have an extended length, so that the weight of the flue material is not resting on the appliance itself.
  • Page 10: Preparation And Installation Instructions

    4 Preparation and Installation instructions Gas connection The gas connection must comply with locally valid standards. We advise Pipe work from the meter to the appliance must be of adequate size., with near the appliance a gas isolater tap that should always be accessible. Place the gas connection in such a way that this is easily accessible, and that before service, the burner unit can be disconnected at all times.
  • Page 11: Mounting The Smoke Emission Outlet Materials

    Mounting the smoke emission outlet materials  In case of a wall or roof terminal, the hole must be at least 5 mm bigger than the diameter of the flue material.  Horizontal parts must be installed at a (3 degree) slope up away the appliance. ...
  • Page 12: Glance Frameless

    Glance Frameless Take the following points into account in connection with the removal of the glass.  Make use of the guide-line (see fig. 2.3 A). Build straight onto this. The guide-line will indicate the minimum window aperture. Never build within this window aperture! (see 2.3 )
  • Page 13: Placing The Decorative Material

    6 Placing the decorative material It is not allowed to add different or more materials to the combustion chamber. Always keep the pilot burner free from decorative material! Do not toss all the decorative material onto the burner all at once, it can be obstructed by dust particles.
  • Page 14: Checking The Installation

    7 Checking the installation. Checking the ignition of the pilot burner, main burner. Start the pilot and main burner according to the instructions in the user’s manual.  Check whether the pilot light is properly positioned above the main burner and is not covered by chips, an imitation log or pebbles.
  • Page 15: Checking The Flame Picture

    Checking the flame picture. Allow the applaince to burn for at least 20 minutes at full and then check the flame picture for: 1. Distribution of the flames 2. Colour of the flames If either one or both points are unacceptable, then check: ...
  • Page 16: Annual Maintenance

    9 Annual maintenance Service and cleaning:  Check and clean if necessary after checking: o The pilot light o The burner (in an LPG flat burner replace the burner sheet) o The combustion chamber o The glass o The logs for possible fractures o The outlet Replace: o (in an LPG flat burner replace the burner sheet)
  • Page 17: Calculation Of Flue System

    11 Calculation of flue system The possibilities for the lengths of flue pipes and the possible restrictors have been recorded in a table (see chapter 12 ) This table works with a vertical and a horizontal length.  To define the vertical length all lengths of flue pipes in a vertical direction should be added up.
  • Page 18: Sample Computations

    11.2 Sample computations Sample calculation 1 Count the horizontal lengths Flue pipe lengths C+E = 1 + 1 Bend D = 1 x 2 m Total Count the vertical lengths Flue pipe length A Roof terminal G Total Sample calculation 2 Count the horizontal lengths Flue pipe lengths J + L = 0,5 + 0,5 1 m Bends...
  • Page 19: Table

    12 Table Find the correct vertical and horizontal lengths in the table. In case of an “x”, or if the values are outside the table, the combination is not permitted. The value found indicates the width of the restrictor to be placed ("0" means no restrictor should be placed).
  • Page 20: Technical Data

    13 Technical data Gascat. II2H3+ II2H3+ II 2H3+ Type appliance C11 C31 C11 C31 C11 of C31 Reference gas Input Nett Efficiency class NOx class mbar inlet-pressure Gas rate at 15ºC and 1013 mbar gr/h Gas rate at 15ºC and 1013 mbar mbar Burner pressure at full mark Injector main burner...
  • Page 21: Dimension Of The Appliance

    14 Dimension of the appliance 20 < < < <...
  • Page 22: Dimension Of The Appliance With Frame

    15 Dimension of the appliance with frame 21 < < < <...
  • Page 23: Ventilation Grills

    16 Ventilation Grills 22 < < < <...
  • Page 24: Dimension Service Hatch

    17 Dimension Service Hatch 23 < < < <...
  • Page 25 24 < < < <...
  • Page 26 Saturnus 8 NL - 8448 CC Heerenveen Postbus 219 NL - 8440 AE Heerenveen T. +31(0)513 656500 F. +31(0)513 656501...