Fig. 16
#7 Installing into an existing chimney
using 3" pl vent in combination with
6" or 8" single or double wall stove
pipe.
This method allows the installer to use 6" or 8"
single and double wall stove pipe ( sealed seam not
snap lock ) and
an existing masonry or class A chimney to vent the
stove.
The stove must use a pl type pellet vent and 90 degree
elbow to start at the stove connector and then use
the approved pipe adapter to connect to the size of
vent that continues into the chimney connector.
Support of the assembly must follow any pipe and
connector manufacturers recommendations
Pipe manufacturer clearance to combustibles,
NFPA and or any local codes must be followed for
this type of installation. Be sure to check with the
pipe manufacturer for clearance to combustibles.
#8 Installing through the ceiling
Through the ceiling vent, follow PLvent
manufacturers recommendations when using a wall
or ceiling pass through. Note: Do not place joints
within wall pass-throughs.
insulation or
er combustible
terials
are
(See Page 6 for
comer installation
12
XXV Pellet Stove