The XXV is a fully automatic stove that features
two operating modes; Stove Temperature Mode and
Room Temperature Mode. In Stove Temperature Mode,
you select a burn rate and the stove will remain at the
same burn rate regardless of the room temperature.
In the Room Temperature Mode the stove
constar~tly monitors the temperature in the room and
adjusts the size of the fire and the heat output of the stove
so that the room is kept at a constant temperature. Room
Temperature Mode, in the AUTO position, has the added
advantage of turning the stove off if no heat is required
and turning the stove on again when the room temperature
drops below your desired room temperature set point.
Room Temperature Mode
Most consumers use the stove in the Room
Temperature Mode because it is the easiest and most
efficient method of keeping the room at a given
temperature. In the Room Temperature Mode, the Room
Sensing Probe constantly monitors room temperature. As
the weather changes outside and your home needs varying
amounts of heat to be at a desired temperature, the stove
will automatically adjust size and heat output of the fire so
that a constant even temperature is maintained. If the
weather warms up and no heat is required the stove will
gradually shut down. When the house cools down the
stove will automatically bring the room temperature to your
desired setting
In the Room Temperature Mode you can select
either Auto or Manual modes for the igniter using the
igniter toggle switch. When the toggle switch is in the
Auto position the igniter located inside the burr1 pot is ready
to automatically light the fire when required. When the
Fig 2o
toggle switch is set to the Manual position the stove can
be lit manually with either a gel or a wax type fire starter. Room Temperature Mode: This setting, see above, will
(see lighting instructions on page 18.) With the ignitertoggle
produces roomtem~eratureof70degree~withthedistribution
switch set in the Manual position the stove will automaticallv
blower
at medium
Weed.
adjust heat output, but the stove will not automatically s h d
down if no heat is required. Instead it will go to its lowest
setting and remain there.
The Manual position on the
igniter toggle switch lets you light the stove manually,
should the igniter fail for any reason. Secondly if you are
using the Harman battery back up system the Manual
setting will prevent the stove from turning off and on during
a power failure, which would drain the back up battery,
and possibly cause damage to the back-up or the stove.
In the Room Temperature Mode, the distribution
blower speed can be increased or decreased by adjusting
the Room Temp/Off/Stove Temp dial between Land H. As
output of the stove increases, the speed of the blower will
increase automatically to insure that more heat is
transferred out into the room. The distribution blower will
shut off as the room reaches the set temperature, this will
prevent overheating of the room.