Dealer Diagnostic Port
For dealer maintenan
only Requires special DDM
monitor supplied to Hanan
Dealers exclusively
Distribution
speed adjustment range.
L=low
H
=
high
Variable speed anywhere
between L and H; although
as the stove temp. goes
up, so does the low end of
the scale.
Mode Selector
/
Allows you to choose
,Temp dial
Allows you to adjust the
room temperature in
Room Temp Mode using
the outer scale marked in
degrees Fahrenheit. It
also allows you to adjust
the stove temperature
while in Stove Temp Mode
using the inner scale
marked from I to 7.
-Indicates power to the
igniter
Status light error messages:
between Room Temp
0
I
Mode, Stove Temp Mode, or
4
lndicates power to the
I Blink: lndicates control board self diagnostic fail-
6 Blinks : Indicates that the control has calculated
we. This requires a manual reset*.
poor or incomplete combustion occurring for more
3 Blinks: lndicates ESP (Exhaust Sensing Probe) than 50 minutes.
failure. This requires a manual reset*.
A six blink status may be set if the stove is allowed
4 Blinks: Can occur only in Room Temp Mode and to run out of pellets. TO reset, turn mode selector to
indicates Room Sensing Probe failed or not installed. "OFF" then back on to the desired mode. If the unit
was not out of pellets see Troubleshooting section,
If a Room Sensing Probe is then installed, the sta-
Page
26,
for more d; t a i l s .
tus light will automatically reset.
* M a n u a l -
disconnect power cord for a few
(In Igniter Auto- Mode Only): Indicates seconds and reconnect. If error still occurs call your
that the unit has failed to light within the 36 minute
start cycle. To reset -Turn Mode Selector to "OFF",
then turn to either mode again.
OFF: Also allows you to vary
XXV Pellet Stove
19
feed motor.
the distribution blower speed
by turning the knob to the
0
high or low side of
0
lndicates power to
v
u
s
t
i
o
n blower
mode.
Igniter switch
Indicates power to
0
Test
Runs all motors at full
speed for one minute to
check operation. After two
distribution blower.
Status Light
Will be lit in either stove
or room temp mode when
I
pointer is not within off
minutes the stove will go to
position band except after
minimum burn and the
normal shut down. Blinks
blowers will alternate from
Feed adjuster
Power Light
to indicate errors listed
high to low every minute to
Sets the maximum feed rate
Indicates power to the control.
below.
remind you that you an? still
in "Test Modeff.