Mobile Home Installation
When installing this unit in a mobile home several
requirements must be followed (Reference HUD Regula-
tion #24CFR3280):
1. The unit must be bolted to the floor. This can be
done by using clips (part # 2-0-677110) and 114" lag
screws.
2. The unit must also be connected to outside air.
See page 8.
3. Floor protection and clearances must be followed
as shown.
4. Unit must be grounded to the metal frame of the
mobile home.
CAU'TION: This appliance must be vented to the out-
side.
Due to high temperatures, the stove should be placed
out of traffic and away from furniture and draperies.
Children and adults should be alerted to the haz-
ards of high surface temperatures and should stay away
to avoid burns to skin and/or clothing.
Young children should be carefully supervised when
they are in the same room as the stove.
Clothing and other flammable materials should not
be placed on or near this unit.
Installation and repair of this Harman stove should be
done by a qualified service person. We recommend that the
stove be inspected before use and at least annually by a
qualified service person. Periodic cleaning is required
Fig. 5: Optional TOP Vent Pipe Clearances
throughout the heating season and at the end of each win-
xxv
Pellet Stove
5
ter for the stove to work efficiently. See cleaning instructions
on page 21.
, -
\
Installing
Place the stove on a noncombustible
floor protector that extends a minimum of 6
inches to the front, 2 inches to the sides and
flush with the rear of the hopper. Ash protec-
tion must also be positioned under any hori-
zontally run flue pipe. The minimum floor pro-
tector material is 20 gauge sheet metal. Other
floor protector materials are ceramic tile,
stone, brick, etc.
Place the stove away from combustible
walls at least as far as shown in Figures 2, 3
and 4.
Note that the clearances shown are mini-
,
mum for safety but do not leave much room
for access when cleaning or servicing. Please take this
into account when placing the stove.
Connect the power cord to a 120 V.A.C. 60Hz
grounded receptacle. (A surge protector is recommended
to protect the circuit board.) If the voltage entering your
home is below 11 6 volts your stove may not work prop-
erly. Also be sure that the polarity of the outlet that the
stove is plugged into is correct.
Prior to installing the flue pipe, connect a draft meter.
(The draft meter must have a minimum range of 0-
.5.)Record the first reading. Connect flue pipe to stove
and be sure all doors and windows in the home are closed.
Record the second draft reading
.
If the second
reading is more than .05" lower than the first reading,
check for possible restrictions or the need for outside air
(see page 8). For more information on the draft test pro-
cedure, refer to Page 20.
,
F
I o o
r
Protection must be 2 inches to
each side, 6 inches to the front, and 0 inches to the
back of the stove. Floor Protector minimum: 32" wide
FLUOR PROTECTOR
Fig.
4
-
I
n
I
-
,noon
VRorEcToR
3'
, .
Fig.
3