PS
DATA: Select when the communication chain uses
•
the PS
DATA protocol.
•
This selection enables the DATA terminal on the
rear panel for communication.
RS-232C: Select when a protocol other than PS
is used.
This selection enables the RS-232C terminal on the
rear panel for communication.
Note: Parallel use of the DATA and RS-232C terminals
is not possible.
G Baud Rate (BAUD RATE)
1. Move the cursor to BAUD RATE with the [D] or [C] but-
ton.
2. Select the rate with the JogDial, and press the JogDial.
The default value is 9600 bits per second.
4800: 4 800 bps
9600: 9 600 bps*
19200: 19 200 bps
G Data Bit (DATA BIT)
1. Move the cursor to DATA BIT with the [D] or [C] but-
ton.
2. Select the bit length with the JogDial.
The default value is 8 bits.
7: 7 bits* ; select when using RS-232C protocol.
8: 8 bits
G Parity Check (PARITY CHECK)
1. Move the cursor to PARITY CHECK with the [D] or [C]
button.
2. Select the check mode with the JogDial.
The default is NONE.
NONE: No parity check
EVEN: Even parity
ODD: Odd parity*
G Stop Bit (STOP BIT)
1. Move the cursor to STOP BIT with the [D] or [C] but-
ton.
2. Select the number of stop bits with the JogDial.
The default is 1.
1: 1 bit*
2: 2 bits
G Wait Time (WAIT TIME)
The unit retransmits data after waiting the specified time if
there is no response from the connected device.
DATA
•
1. Move the cursor to WAIT TIME with the [D] or [C] but-
ton.
2. Select the waiting time with the JogDial.
The default is OFF.
OFF: Retransmission is disabled. *
100MS: 100 m seconds
200MS: 200 m seconds
1S: 1 second
G Control Unit Address (CTL-UNIT
ADDRESS) (only for PS
When the recorder performs as a controller in the system,
the unit address can be set from the setup menu on the
monitor.
1. Move the cursor to CTL-UNIT ADDRESS with the [D] or
[C] button.
2. Select the address with the JogDial.
The default value is 1.
Assignable address: From 1 to 99, must be unique in
the chain.
Note: Assign an address except 1 to WJ-HD220 when
using a system controller in the system.
G System Unit Address (SYS-UNIT
ADDRESS) (exclusive to PS
When the recorder performs as a system unit, the unit
address can be set from the setup menu on the monitor.
1. Move the cursor to SYS-UNIT ADDRESS with the [D] or
[C] button.
2. Select the address with the JogDial.
The default value is 1.
Assignable address: From 1 to 99, must be unique in
the chain.
DATA)
•
DATA)
•
39