4-1. Equipment Required
. Oscilloscope
Sony Tektronix 2465 or equivalent (with bandwidth of
350 MHz)
. NTSC/PAL/SECAM component signal generator
Sony Tektronix TG2000 +AVG1 (option module)
+AWVG1 (option module) or equivalent
. Monoscope signal generator
ShibaSoku TP22AX or equivalent
. VG (programmable video signal generator)
VG814 or equivalent
. Frequency counter
Advantest TR5821AK or equivalent
PVM-14L5/20L5/D14L5A/D20L5A
Section 4
Electrical Adjustments
. Digital VOM
Advantest TR6845 or equivalent
. Variable auto-transformer
. High tension voltmeter
. DC power supply
. Ammeter
. Luminance meter
Minolta CA-110 or equivalent.
If the Minolta CA-110 is not available, perform the
measurement by visual inspection by comparing the
monitor that has already been adjusted earlier with the
monitor that you want to adjust.
n
Start the following adjustments after 5 minutes have
passed after the main power is turned on.
4-1