MU-GA35VB
OUTDOOR UNIT
NAME
SYMBOL
C1
COMPRESSOR CAPACITOR
C2
OUTDOOR FAN CAPACITOR
DSAR
SURGE ABSORBER
F
FUSE (T20AL250V)
NOTE:1. About the indoor side electric wiring refer to the indoor unit electric wiring diagram for servicing.
2. Use copper conductors only. (For field wiring)
3. Symbols below indicate.
/: Terminal block,
: Connector
7
REFRIGERANT SYSTEM DIAGRAM
MU-GA20VB
MU-GA25VB
MU-GA35VB
OUTDOOR UNIT
Flared connection
Flared connection
Refrigerant pipe [6.35
(with heat insulator)
TB2
WHT
2
BLK
1
CIRCUIT
BREAKER
TB1
BRN
L
BLU
N
PE
SYMBOL
MC
COMPRESSOR
MF
OUTDOOR FAN MOTOR (INNER FUSE)
TB1
TERMINAL BLOCK
TB2
TERMINAL BLOCK
Refrigerant pipe [9.52
(with heat insulator)
Stop valve
(with service port)
Stop valve
52C
DSAR
BRN
52C
F
51C
BRN
WHT
4
NO
COM
C1
RED
BLK
WHT
C2
RED
3
2
WHT
1
NAME
Compressor
Capillary tube
[3.0x[1.4x700 (MU-GA20VB
[3.0x[1.4x900 (MU-GA20VB
[3.0x[1.4x450 (MU-GA35VB)
7
WHT
1
C
MC
S
R
RED
BLK
MF
WHT
SYMBOL
NAME
51C
OVERLOAD RELAY
52C
COMPRESSOR CONTACTOR
Muffler
Outdoor
heat
exchanger
Strainer
#100
-
, MU-GA25VB
E1
-
, MU-GA25VB
E2
Refrigerant flow in cooling
Unit:mm
-
)
E1
-
)
E2