9. HRS METER (Hours meter)

The data of "HRS METER" of the menu are memorized in addresses 00 to 13 of page A. (VC-358D board IC1105 (EEPROM)). When
replacing the drum assy. capstan motor or mechanism deck, reset the data of the addresses corresponding to the replaced parts to "00".
Note: Same data is memorised in two addresses, so be sure to reset both addresses.
Page A
Address 00 to 13
Address
Name
00
OPERATION (L)
01
OPERATION (H)
02
DRUM RUN (L)
03
DRUM RUN (H)
04
TAPE RUN (L)
05
TAPE RUN (H)
06
THREADING (L)
07
THREADING (H)
08
CHECK SUM (L)
09
CHECK SUM (H)
0A
OPERATION (L)
0B
OPERATION (H)
0C
DRUM RUN (L)
0D
DRUM RUN (H)
0E
TAPE RUN (L)
0F
TAPE RUN (H)
10
THREADING (L)
11
THREADING (H)
12
CHECK SUM (L)
13
CHECK SUM (H)
Resetting method:
1)
Select page: 0, address: 01, and set data: 01.
Select the addresses indicated by z in the following table corresponding to the replaced parts, and input data: 00.
2)
Note: Press the PAUSE button of the adjustment remote commander each time to set the data.
Replaced parts
Mechanism deck
Drum assy
Capstan motor
3)
Select page: 0, address: 01, and set data: 01.
HRS METER data re-writing procedure
When a user forgets a password, replace IC1105 (EEPROM) on VC-358D board. At this time, replace IC1105 in the following order to copy
the HRS METER data.
Processing before replacing IC1105:
1)
Note down the data of page: A, address: 00 to 13.
Processing after replacing IC1105 :
1)
Select page: 0, address: 01, set data: 01.
2)
Select page: A, address: 00 to 13, and input the data noted down.
Note: Press the PAUSE button of the adjustment remote commander each time to set the data.
3)
Select page: 0, address: 01, set data: 00.
Power supply operation counted time (Lower digits)
Power supply operation counted time (Upper digits)
Drum rotation counted time (Lower digits)
Drum rotation counted time (Upper digits)
Capstan rotation counted time (Lower digits)
Capstan rotation counted time (Upper digits)
Unloading counter (Lower digits)
Unloading counter (Upper digits)
Check sum (Lower digits)
Check sum (Upper digits)
Power supply operation counted time (Lower digits)
Power supply operation counted time (Upper digits)
Drum rotation counted time (Lower digits)
Drum rotation counted time (Upper digits)
Capstan rotation counted time (Lower digits)
Capstan rotation counted time (Upper digits)
Unloading counter (Lower digits)
Unloading counter (Upper digits)
Check sum (Lower digits)
Check sum (Upper digits)
Address
02, 03, 0C, 0D
04, 05, 0E, 0F
(DRUM RUN)
(TAPE RUN)
z
z
z
z