Chapter 12
Cisco ASR 1001 Router Overview and Installation
The Cisco ASR 1001 Router can support two AC or two DC power supplies. Do not mix AC and DC
Note
power supply units in the same chassis.
Figure 12-21
Figure 12-21
1
8
1
AC and DC power supply fasteners
2
AC power supply inlet
3
Power supply LED
4
DC power supply negative (-) connection
Table 12-8
DC power supplies.
Table 12-8
LED Color and State
Solid green
Blinking green, at the rate of one
blink per second
Solid amber
Blinking amber, at the rate of one
blink per second
Off
OL-13208-11
shows both the AC and DC power supplies for the Cisco ASR 1001 Router.
Cisco ASR 1001 Router AC Power Supply and DC Power Supply
3
2
1
10 0- 24 0
V~
5- 2A
50 -6 0H z
1
8
describes the power supply LED. The function of the LED is the same for both the AC and
Cisco ASR 1001 Router AC and DC Power Supply LED
Cisco ASR 1000 Series Aggregation Services Routers Hardware Installation Guide
Cisco ASR 1001 Router Power Supply Installation
4
5
6
-4 8V /-6 0V
14 A
7
3
1
5
DC power supply positive (+) connection
6
DC power supply ground symbol
7
DC power supply terminal block connection
8
AC and DC power supply handles
Description
Power output is on and within the normal operating range.
Input power that is within the normal operating range is being
supplied, but the Standby switch is in the Standby position (and
not in the On position).
A power supply critical event has occurred, and the power
supply has shut down. The critical event can be temperature,
voltage, current, or fan operating outside the normal operating
range.
A power supply warning event has occurred, but the power
supply can continue to operate. The warning event can be
temperature, voltage, current, or fan operating outside the
normal operating range.
Power supply is shut down.
12-33