Chapter 14
Removing and Replacing FRUs from the Cisco ASR 1000 Series Routers
To remove the Cisco ASR1000-RP and then the eUSB device from the chassis, follow these steps:
Step 2
Attach an ESD-preventive wrist strap between you and an unpainted router surface.
a.
If connected, remove any I/O cables from the Cisco ASR1000-RP.
b.
Using a number two Phillips or a 3/16-inch flat-blade screwdriver, loosen the two captive screws on
c.
the faceplate of the Cisco ASR1000- RP.
Using the handles on both sides of the module, with two hands, gently slide the module out of the
d.
chassis slot.
Caution
Handle the Cisco ASR1000-RP by the carrier edges only; never touch the printed circuit board
components or connector pins.
Place the Cisco ASR1000-RP module on an antistatic surface with its printed circuit board
e.
components facing upward.
Locate the eUSB device on the ASR1000 Series RP board.
f.
eUSB component on the Cisco ASR1000-RP1 and
component on the Cisco ASR1000-RP2 route processor.
Figure 14-29
1
Cisco ASR 1000 Series RP1 eUSB device
location
Remove the small Phillips screw holding the eUSB board in-place (see
g.
OL-13208-11
Cisco ASR1000-RP1 eUSB Location
1
Cisco ASR 1000 Series Aggregation Services Routers Hardware Installation Guide
Removing and Replacing Cisco ASR 1000 Router eUSB Devices
Figure 14-29
Figure 14-16
shows the location of the eUSB
— —
Figure
shows the location of the
14-30).
14-39