Chapter 14
Removing and Replacing FRUs from the Cisco ASR 1000 Series Routers
Figure 14-31
1
Phillips screw
2
eUSB connector
Replace the Cisco ADR1000-RP into chassis and remove any external USB sticks.
Step 3
Once the new eUSB is installed and BinOS has successfully booted, this verifies that the new eUSB is
Note
functioning properly.
Restore the backup copy of the startup-config and boot image to the eUSB device.
Step 4
Router# copy nvram:startup-config stby-nvram:startup-config
Router# copy bootflash:asr1000rp1-adventerprisek9.02.01.00.122-33.XNA.bin
stby-bootflash:
Verify that the Cisco ASR1000-RP1 is operating properly. Check that the internal hard drive LED
Step 5
(labeled as DISK HD) is flashing green. To check if the LED flashes green, from the ROMMON or IOS
prompt, perform a:
dir harddisk
To restore data after the internal hard drive replacement, type:
Step 6
archive tar/xtrac tftp:usb0:asr1000.tar harddisk:
You have completed the replacement procedure for the eUSB device on a Cisco ASR1000-RP module.
OL-13208-11
Cisco ASR1000 Series RP eUSB Device Removal and Replacement
1
3
2
Cisco ASR 1000 Series Aggregation Services Routers Hardware Installation Guide
Removing and Replacing Cisco ASR 1000 Router eUSB Devices
3
Standoff
— —
14-41