BRIDGE MODE SETTING SCREEN
8. [Port Settings] Menu (continued)

M Serial Communication

Set the serial communication details.
Note: The setting items appear only when "Enable" is selected in [Serial Communication].
Client Mode:Disable
q
w
e
y
u
i
o*
!0 *
!1 *
!2 *
!3 *
*Appears only when "Manual" is selected in [Data mode].
q Serial Communication ..........
w Client Mode ..........................
e TCP Port Number .................
r Server Address. . ......................
t Server Port Number................
y Communication Control ........
u Signal Level ..........................
i Data Mode .....................
o Baud Rate .............................
!0 Data Bits. . .................................
!1 Parity. . .......................................
!2 Stop Bits. ..................................
!3 Session Timer. . ........................
!4 Connection Status. . .................
[Port Settings]–[EXT Output 1 (EXT1)/EXT Output 2 (EXT2)]
Client Mode:Enable
q
w
r
t
y
u
o
!0
!1
!2
!4
Select "Enable" to use the serial communication.
Select "Enable" to use the serial communication as the client. (Default: Disable)
Enter the port number between 1024 and 65535.
Enter the destination VE-PG3's IP address.
Enter the destination VE-PG3's port number.
Range: "1024" to "65535"
Select the communication type.
Select the serial communication line signal level from "±5 V (RS-232C),"
"0V/5V (Logic)" and "0V/3V (Logic)."
Select the communication method for the Serial Communication between a
device and the VE-PG3.
• Auto:
Automatically starts the serial communication from a Virtual
Serial Port installed on your PC.
• Manual:
Manually sets a serial communication method for a device.
Select a serial communication speed between a device and the VE-PG3.
Select the number of bits for the serial communication between 5 and 8.
Select a parity bit of [none], [odd], or [even].
Select the stop bit length for the data of 1 or 2.
Set the time to cut the TCP session when there is no communication from the host.
Range: 0 to 86400 seconds *The timeout does not occur when "0" is set.
Displays the connection status. Click "Connection" to connect the serial com-
munication.
5-98
(Default: Disable)
(Default: EXT1= 50002, EXT2= 50003)
(Default: EXT1=50002, EXT2=50003)
(Default: Full-Duplex)
(Default: ±5 V (RS-232C))
(Default: Auto)
(Default: 9600)
(Default: none)
(Default: 8)
(Default: 1)
(Default: 30)