3
CONVERTER MODE APPLICATION
4. Making an emergency announcement (continued)

2. Connection

Set the transceiver channel, volume level, TX output power, and other necessary settings, before connecting to the
VE-PG3.
NOTE:
• Full duplex communication is impossible.
Communicate with each other by taking turns speaking.
• Pause briefly before you speak, to confirm your party has finished speaking.
• The communication route will be disconnected when the IP telephone's handset is put on the hook, or the VE-PG3 receives no
audio for the preset time (default: 15 seconds).
1
Connect the VE-PG3 and the transceiver using the OPC-2275 cable.
• Verify that both the VE-PG3 and the transceiver are turned OFF when connecting the cable.
To [TRX1] (Upper slot)
A A B C
• The [TRX1] and [TRX2] ports (upper slots) accept the OPC-2275 connectors.
However, follow the example to correctly connect the transceiver to ONLY the [TRX1] slot.
2
Make a cable the length you need, with two connectors wired as shown, and the appropriate connectors for
your audio device. Then connect it to the [EXT1] on the VE-PG3 and then to your audio device.
• See Section 8 for the port details.
To [EXT1] (lower slot)
A
B
1 2 3 4
1 2 3 4
3
When all the connections are completed, turn ON the transceiver and VE-PG3's power.
VE-PG3 (Rear view)
LINE2 LINE1
PHONE
Be sure to insert the
A B C
connectors top side up.
OPC-2275
A
1 2 3 4
A1 A2 A3 A4
Icom's transceiver
(IC-F5060/IC-F6060 series)
To the external speaker jack
A
1
2
3
4
Top
Bottom
B
Connector pin configuration
A1: Audio output (OUT)
A2: Audio output ground
A3: Audio input (IN)
A4: Audio input ground
1 2 3 4
B3: Control input
B1 B2 B3 B4
B4: Control ground
3-19