4
ANALOG TELEPHONE APPLICATION
Telephone function (continued)

2. Connection

Set the transceiver channel, volume level, TX output power, and other necessary settings, before connecting to the
VE-PG3.
1
Connect the VE-PG3 and the transceiver, using the appropriate optional cable.
• Verify that both the VE-PG3 and the transceiver are turned OFF when connecting the cable.
To [TRX1] (Upper slot)
A A B C
• The [TRX1] and [TRX2] ports (upper slots) accept the OPC-2275 connectors,
However, follow the example to correctly connect the transceiver to ONLY the [TRX1] slot.
2
When all the connections are complete, turn ON the transceiver and VE-PG3's power.
NOTE:
• Verify that both the radio and the VE-PG3 are turned OFF when connecting or disconnecting the transceiver.
• Keep the radio away from a PC, AC adaptor and other electronic equipment. The noise emitted from those equipment may
interfere with the radio.
• When operating the radio, do not transmit near the IP telephone.
VE-PG3 (Rear view)
PHONE
A B C
OPC-2275
LINE2 LINE1
Be sure to insert the
connectors top side up.
A
1
2
3
4
Top
Bottom
4-3
Icom's transceiver
(IC-F5060/IC-F6060 series)
To the external speaker jack
To the microphone connector
(Rear view)