6. SPECIFICATIONS OF ELECTRICAL PARTS

6-1. Indoor Unit
RAS-B10SKVP-E, RAS-B13SKVP-E, RAS-B16SKVP-E
RAS-10SKVP-ND, RAS-13SKVP-ND, RAS-16SKVP-ND
No.
Parts name
1
Fan motor (for indoor)
2
Room temp. sensor (TA-sensor)
3
Heat exchanger temp. sensor (TC-sensor)
4
Heat exchanger temp. sensor (TCJ-sensor)
5
Louver motor
6-2. Outdoor Unit
RAS-10SAVP-E, RAS-13SAVP-E, RAS-16SAVP-E
RAS-10SAVP-ND, RAS-13SAVP-ND, RAS-16SAVP-ND
No.
Parts name
1
Reactor
2
Outside fan motor
3
Suction temp. sensor (TS sensor)
4
Discharge temp. sensor (TD sensor)
5
Outside air temp. sensor (TO sensor)
6
Heat exchanger temp. sensor (TE sensor)
7
Terminal block (6P)
8
Compressor
9
Coil for P.M.V.
10
Coil for 4-way valve
11
Cord heater assembly (-ND model only)
12
Heater fuse assembly (-ND model only)
Type
MF-280-30-5R
( – )
( – )
( – )
MP24Z3N
Model name
CH-57
ICF-140-43-4R
(Inverter attached)
(Inverter attached)
(Inverter attached)
(Inverter attached)
——
DA111A1F-24F
CAM-MD12TF
STF
CSC-2
——
www.ilmalämpöpumput.com
– 22 –
Specifications
DC280–340V, 30W
10kΩ at 25°C
10kΩ at 25°C
10kΩ at 25°C
Output (Rated) 1W, 16 poles, DC12V
Rating
L = 10mH, 16A
DC140V, 43W
10kΩ (25°C)
62kΩ (20°C)
10kΩ (25°C)
10kΩ (25°C)
20A, AC250V
3-phases 4-poles 750W
DC12V
AC220–240V
AC230V, 75W
AC250V, 3.15A