USER INTERFACE
Enable User
Select the check box to enable User Sockets and reveal the related configuration
options.
Socket
Enable Data
Select the check box to enable User Sockets and reveal the related configuration
Transmission
options. When enabled, Ethernet User Socket is selected as the channel to be used
by the scanner for transmitting data and/or messages.
Heartbeat
Select Disable, Enable Unconditioned, or Enable Conditioned from the drop-down
list. This parameter is available when the Data TX parameter is checked. It
enables/disables the transmission of the Heartbeat message signaling that the device
is still active.
Disable: The Heartbeat message is not transmitted
Enable Unconditioned: The Heartbeat message is always transmitted, even if
communication is still active
Enable Conditioned: The Heartbeat message is transmitted only when there is no
communication
Heartbeat
Enter a time value in seconds to define the amount of time between two message
Timeout
transmissions. If the input timeout expires and no transmission has occurred, the
Heartbeat message will be transmitted.
Heartbeat
Click
Message
beginning of the heartbeat message. Characters from NUL (00H) to ~ (7EH) can be
(max. 32
used. Click Submit to save your text to the origin window text field, or click Cancel to
chars)
return to origin window without transferring text.
The Heartbeat Message (header) string must be different from the Heartbeat
Terminator string.
Heartbeat
Click
Terminator
signal the end of the heartbeat message. Characters from NUL (00H) to ~ (7EH) can
(max. 32
be used. Click Submit to save your text to the origin window text field, or click Cancel
chars)
to return to origin window without transferring text.
The Heartbeat Terminator string must be different from the Heartbeat Message
(header) string.
Type
Select Server or Client from the drop-down list to define the type of the socket:
Server: The station waits for connections and can communicate with a maximum of
3 clients simultaneously
Client: The station tries a connection towards the server
Enter the IP address of the server to which the client tries to connect. This parameter is
Server
Address
available only when the socket is configured as a Client.
USER SOCKET N
Heartbeat Settings
to activate the Text Entry Tool and create heartbeat header text to signal the
to activate the Text Entry Tool and create Heartbeat Terminator text to
Socket Configuration
4
105