MAINTENANCE
6.2.4 Tighten Mounting Hardware
1. Check all barcode scanner, CBX connection box(if applicable), SC5000 Controller (if
applicable), and power supply mounting hardware as applicable. Tighten as
necessary. Do not over-tighten. Be sure not to disturb the equipment's alignment as it
relates to the product transport.
2. Check the mounting hardware of the Photoelectric Sensor (if this option is being
used). Tighten as necessary. Do not over-tighten.
3. Check the mounting hardware of the tachometer (if this option is being used). Tighten
as necessary. Do not over-tighten.
6.2.5 Checking Barcode Scanning System Connections
Wiring connections to the barcode scanners are made between the connector panel and
CBX connection box and/or SC5000 Controller.
(See Chapter 3, Electrical Installation.)
1. Check all wiring connections to the connector panel. Tighten any loose connections
as necessary. Do not over-tighten.
2. Check all wiring connections to the CBX connection box and/or SC5000 Controller.
Tighten any loose connections as necessary. Do not over-tighten.
3. Check all cabling/conduit for signs of wear/damage. Repair/replace any damaged
cable connections as necessary.
6.2.6 Verify Barcode Scanner Operation
If after performing maintenance, the barcode scanning system continues to perform below
the normal operations experienced with the system under normal daily conditions, contact
Datalogic through our website at www.datalogic.com.
6.2.7 Verify Photoelectric Sensor Operation
1. Block the Photoelectric Sensor emitter beam to confirm it is aligned properly with the
reflector.
2. Verify that the TRIGGER LED on barcode scanner lights YELLOW when
photoelectric sensor beam is blocked.
If the photoelectric sensor's LED does not change status, adjust the photoelectric
sensor so that it is properly aligned with the reflector.
If the TRIGGER LED on the barcode scanner is not green when the photoelectric
sensor's beam is blocked, check the cabling between the photoelectric sensor and
CBX510 or SC5000 for damage.
6
227