Re-Entering The Server Serial Number - HP ProLiant ML310 Maintenance And Service Manual

Hide thumbs Also See for ProLiant ML310:
Table of Contents

Advertisement

IMPORTANT: Positive (+) polarity must be positioned up.
5. Slide the replacement battery into the proper position with the positive (+) side up.
6. Replace the server access panel and connect cables to the server.
7. Run RBSU to reconfigure the server by pressing the F9 key when prompted during server
startup. Refer to the ROM-Based Setup Utility User Guide for more information on
RBSU.

Re-entering the Server Serial Number

After replacing the system board or clearing the NVRAM, the server serial number must be
re-entered.
1. During the server startup sequence, press the F9 key to access RBSU.
2. Select the System Options menu.
3. Select Serial Number. The following warning is displayed:
WARNING! WARNING! WARNING! The serial number is loaded into the
system during the manufacturing process and should NOT be
modified. This option should ONLY be used by qualified service
personnel. This value should always match the serial number
sticker located on the chassis.
Press the Enter key to clear the warning.
4. Enter the serial number and press the Enter key.
5. Press the Escape key to close the menu.
6. Press the Escape key to exit RBSU.
7. Press the F10 key to confirm exiting RBSU. The server will automatically reboot.
HP ProLiant ML310 Server Maintenance and Service Guide
Removal and Replacement Procedures
2-41