FO-4500H
18
Paper exit sensor
Fig. 18
1. Remove the Paper Exit Sensor (PC3).
2. Remove the two G-rings from the Fusing Unit.
NOTE:
When reinstalling the G-rings:
•
Be careful of the direction.
•
Securely position them into the grooves of the Fusing Roller.
3 – 27