When installing and operating your Harman® Accentra Pellet Stove, respect basic safety standards. Read these instructions
carefully before you attempt to install or operate the Accentra. Failure to do so may result in damage to property or personal
injury and may void the product warranty.
Several issues must be addressed when selecting a suitable location for your Accentra Pellet Stove. Observing required
clearances to combustible materials, the proximity to a safe chimney or venting system, and the accessibility of electrical
supply must all be considered.
Place the stove away from combustible walls at least as far as shown in figures 10, 11, & 13.
Clearances may Only be reduced using methods Approved by the regulating Authority having jurisdiction.
Note that the clearances shown are minimum for safety but do not leave much room for access when cleaning or service
is needed.
Alternate floor protector dimension may be used as long as they satisfy the
measurement requirements shown below.
Minumum size floor protection for a corner installation hearth pad is 24
x 28
The Clearance to The Top of The Unit is 60" (152cm) Measured From The
Floor.
3-90-08326R25_06/13
".
5/8
2.25"
57mm
Fig.11
305mm
This is the minimum size Harman® recommends for an
alcove with a 60" ceiling.
14.75"
2.25"
6.25"
159mm
12"
14.75"
54"
"
1/16
5" min.
Fig. 13