When installing the Accentra in a mobile home several
requirements must be followed:
1. The unit must be bolted to the floor. This can be done with
1/4" lag screws through the 2 holes in the base plate shown
in Fig. 16
2. The unit must also be connected to outside air. See page
15.
3. Floor protection and clearances must be followed as
shown on page 10.
4. Unit must be grounded to the metal frame of the mobile
home.
5. Chimney must meet requirements of CAN/ULC-S629,
Standard for 650°C Factory Built Chimneys. Follow
Manufacturer's guidelines concerning height and
clearances to combustibles. Use the same manufacturer's
components to provide an effective vapor barrier where
the chimney or other component penetrates to the exterior
of the mobile home. dO NOT mIX COmPONENTS FrOm
dIFFErENT mANuFACTurErS. The top section of
chimney and the chimney cap must be removable to a
maximum height of 13.5' for transport of the mobile home.
CAuTION: This appliance must be vented to the outside.
Due to high temperatures, the Accentra should be placed
out of traffic and away from furniture and draperies. Children
and adults should be alerted to the hazards of high surface
temperatures and should stay away to avoid burn to skin and/
or clothing. Young children should be carefully supervised
when they are in the same room as the stove. Clothing and
other flammable materials should not be placed on or near
the Accentra Pellet Stove.
Installation and repair of the Accentra Pellet Stove should
be done by a qualified service person. The appliance should
be inspected before use and at least annually by a qualified
service person. More frequent cleaning will be required.
It is imperative that control compartments, burners, and
circulating air passageways of the Accentra be kept clean.
wArNINg! dO NOT INSTAll IN SlEEPINg rOOm
mObIlE hOmE INSTAllATION ShOuld bE dONE IN
ACCOrdANCE wITh ThE mANuFACTurEd hOmE ANd
SAFETY STANdArd (hud), CFr 3280, PArT 24.
AFTEr ThE INSTAllATION IS COmPlETE
Before the first fire is lit, check and record the high and low
draft reading numbers on page 13. Make adjustments to the
low draft at this time, if necessary.
3-90-08326R25_06/13
mobile home Installation
Fig. 16
Unit bolt down holes for mobile home installation lag to floor
with 1/4" diameter lag bolts with washer. (not supplied.) Note:
If the optional leg kit is used, a longer bolt will be required.
Canadian Standard ulC S627 requires that all outdoor-
aired space heaters must be attached to the structure.
CAuTION
ThE STruCTurAl INTEgrITY OF ThE mObIlE
hOmE FlOOr, wAll, ANd CEIlINg/rOOF muST bE
mAINTAINEd.
CAuTION
ThE STOvE IS hOT whIlE IN OPErATION.
KEEP ChIldrEN, ClOThINg ANd FurNITurE AwAY.
CONTACT mAY CAuSE SKIN burNS.
wArNINg
KEEP COmbuSTIblE mATErIAlS SuCh AS grASS,
lEAvES, ETC. AT lEAST 3 FEET AwAY FrOm ThE
POINT dIrECTlY uNdEr ThE vENT TErmINATION.