room Sensor and rear Shield Installation
room Sensor Installation
Fig. 19
The room sensor is a small temperature sensor on the end of
a 60" wire. This sensor is installed much like a standard wall
thermostat. Because it is so small, it can be hidden along the
trim of a doorway or even up the leg of a coffee table. There
is a remote room sensor port on the rear of the unit for easy
external connection. Use standard 18-2 thermostat wire to
extend the distance to the desired location (100' maximum).
The room sensor should be installed in the location where
you want to control the temperature.
NOTE: Distances of more than 25 feet from the unit or in
another room are not recommended. The room sensor is
essential for the Accentra's excellent efficiency.
It is recommended that the room sensor be installed,
even if only installed on the rear of the unit as a return air
sensor. There is an intake screen on the bottom of the rear
sheet metal enclosure. This is an ideal place to tie wrap the
sensor head to sense return air temperature.
3-90-08326R25_06/13
rear Shields
5/16" Hex Head
Screws (2 on
each side)
The rear insulated shields are split in the middle for easy
removal. Each shield has two 5/16" hex head screws that only
need to be loosened (NOT REMOVED) to allow the shield
to slide away from the unit. NOTE: It is not recommended
that the unit be operated with the shields removed, due
to the hot and moving parts which they protect.
rEmINdErS
Fig. 21
Do not allow pellets or sawdust to build up on the hopper lip.
Inspect the hopper lid gasket for damage. A good hopper lid
seal is very important for proper operation.
NOTE: All PACKAgINg & ShIPPINg mATErIAlS
muST bE rEmOvEd FrOm ThE STOvE bEFOrE
OPErATINg.
5/16" Hex Head
Screws (2 on
each side)
Fig. 20
Hopper Lid Foam
Gaskets
Hopper lip