Fig. 25
Fig. 26
3-90-08326R25_06/13
venting
3 ft.
to combustibles
Combustibles
3 ft.
to combustibles
3 ft.
to combustibles
Combustibles
3 ft.
to combustibles
#1 Preferred method
This method provides excellent venting for normal operation
and allows the stove to be installed closest to the wall. Two
and a half inches from the wall is safe; however, three
inches allows better access to remove the rear panel. The
vertical portion of the vent should be three to five feet high.
This vertical section will provide natural draft in the event
of a power failure. Note: do not place joints within wall
pass-throughs.
#2 Preferred method
This method also provides excellent venting for normal
operation but requires the stove to be installed farther from
the wall. The vertical portion of the vent should be three to
five feet high and at least three inches from a combustible
wall. This vertical section will provide natural draft in the
event of a power failure. Note: do not place joints within
wall pass-throughs.
KEEP COmbuSTIblES (SuCh AS grASS,
lEAvES, ETC.) AT lEAST 3 FEET AwAY FrOm
ThE FluE OuTlET ON ThE OuTSIdE OF ThE
buIldINg.
CAuTION