This heating appliance does not just have automatic ignition, it has total automatic temperature control. The Accentra has
an input heat range from 0 to 40,000 BTU's. This patented feed system has a maximum feed rate of 5 lbs. per hour and a
minimum (maintenance) feed rate of .75 lbs. per hour and then "off" if necessary. The hopper holds approximately 50 pounds
of fuel. The unit has an easy to clean combustion system with an ash pan that holds ash from 1 ton of burned premium pellets.
The control is designed for easy and efficient operation. It has 2 automatic modes of operation and 2 manual modes of
operation.
The Accentra uses a small room sensor rather than a wall thermostat for more accurate temperature control. This unit is
equipped with several different safety devices which will be explained later in this manual. With its specially designed burn
pot and the "Advance Igniter" Automatic Ignition System, the unit can burn a large variety of pelletized fuels with varying
ash content. The accordion style cast iron heat exchanger system allows maximum surface area for the most efficient heat
transfer in a smaller firebox.
For Your Safety: When installing a solid fuel appliance, it is also recommended to install Smoke and Carbon Monoxide Detectors
on every level of the house. During the initial firing of the appliance, some smoke or odor may occur due to paint curing. You
may want to keep some windows open for ventilation during the first few hours of burning to prevent smoke detector activation.
Test your smoke and carbon monoxide detectors regularly.
SAFETY NOTICE: IF THIS Harman® ACCENTRA PELLET
STOVE IS NOT PROPERLY INSTALLED. A HOUSE FIRE MAY
RESULT. FOR YOUR SAFETY, FOLLOW THE INSTALLATION
DIRECTIONS. CONTACT LOCAL BUILDING OR FIRE
OFFICIALS ABOUT RESTRICTIONS AND INSTALLATION
INSPECTION REQUIREMENTS IN YOUR AREA.
Safety testing by Omni-Test Laboratories
ASTM-E1509-04 • ULC-S627-00 &
ULC/ORD-C1482-M1990• Report # 135-S-10b-2
This appliance is also approved for
installation into a shop.
352 Mountain House Road
Halifax, PA 17032
www.harmanstoves.com