Note: these instructions should be read carefully and retained for future reference. Please leave these instructions with the user. The Glance is developed to be installed either with a frame (see figure 1) or frameless (see figure 2) on both sides. A combination of both is also possible what makes three possibilities: •...
2 Safety and general information Before installation, ensure that the local distribution conditions (identification of the type of gas and pressure) and the adjustment of the appliance are compatible. This gas appliance is factory set and can not be adjusted. This appliance does not contain any component manufactured from asbestos or any asbestos related products.
• always ventilate the space above the appliance. Use a Faber ventilation grid • to avoid cracking, the plaster has to dry for at least 1 day per millimetre plaster •...
Page 10
4. elbows and bends at the transition of horizontal to vertically are not to be counted 5. the wall mounted terminal counts for 1 meter 3.2.1 Terminal position Verify if the required terminal position meets the local installation regulations regarding disturbance, good functioning and ventilation (see also appendix G).
4 Instruction for Installation Gas Connection Installation pipes should be in accordance with BS 6891. Pipe work from the meter to the appliance must be of adequate size. The complete installation including the meter must be tested for soundness and purged as described in the above code.
Page 12
• Position the gas control in a way it will be accessible behind the inspection lid • Prepare the gas connection • Check the appliance height again and adjust when necessary. Make sure the appliance is level • Assemble the flue system onto the firebox Placing a fire with frame in a wall •...
Page 13
Placing the log set • First place the chips all over the burnerplate, see the card delivered with the logset • Spread the chips as much as possible (keep the pilot burner area free of chips) • Place the log set as shown Placing the pebbles •...
5 Commissioning (functional checks) Pilot ignition check • Ignite the pilot light as described in the user manual • Check if the pilot burner stays alight • Extinguish the pilot burner Check functional burner and pilot burner The appliance is preset to give the correct heat input. No further adjustment is necessary. Always check the inlet pressure and burner pressure: •...
6 Handing over (final check and customer briefing) • Instruct the customer on the full operation of the appliance and the remote control, including replacement of batteries • Advise the customer how to clean the appliance including the glass • Hand over these instructions including the user guide to the consumer •...
Page 16
Attention: Before placing the glass: check the glass sealing rope is in good condition and makes an effective seal. Be sure that there are no fingerprints on the glass. It is not possible to remove those prints after you burn the appliance for a while (they are burnt in). Place the glass in front of the appliance and fix the glass frame or use the glass clamps.
Appendix A: Example calculation Calculation 1: Calculating horizontal extension fig. 2a: Flue lenght C + E = 1m + 1m Elbows D = 2m Total horizontal extension Measure or calculate effective height (Hvert) Flue lenght A Roof mounted terinal Total effective height When calculating table 2: It is allowed.
Determine according to the table the right flue restrictor size • When meeting an X, and when the values are outside the table, the combination is not allowed • Normally the 30 mm flue restrictor is preinstalled Horizontale lengte (m) Glance < < < <...
Appendix C: Installation of the flue Connection with use of concentric duct material Make a hole of ø 153 mm for the wall or roof mounted terminal. The horizontal pipes need to rise away from the appliance at a rate of 3 degrees per metre Build the system starting from the appliance on.
Page 20
1. Place the aluminium closure plate (A) onto the chimney. Permanently attach and make airtight. 2. Pull the liner (C) through the chimney. 3. Connect the liner onto the roof terminal and fix this with the clamp provided with the chimney connection set.
Appendix E: Technical specifications Country II 2H+ II 2H+ II 2H+ II 2H+ Appliancetype C11 of C31 C11 of C31 C11 of C31 C11 of C31 Reference gas Input (nett) [kW] Efficiency class Inlet pressure [mbar] Gasrate (15ºC & 0.935 m 640g/h 0.935 m 640g/h...
Appendix G: Terminal position Dimension Terminal position Balanced flue room (kW input 7.5 kW expressed in net) sealed Natural Draught Direct below an opening, airbrick, opening windows, etc. Above an opening, airbrick, opening window, etc. Horizontally to an opening, airbrick, opening window, etc. Below gutters, soil pipes or drain pipes Below eaves Below balconies or carport roof...
Page 25
– info@faber.nl Saturnus 8 NL - 8448 CC Heerenveen Postbus 219 NL - 8440 AE Heerenveen T. +31(0)513 656500 F. +31(0)513 656501 40010576 0612...