Routine Maintenance
6
Close the Front Cover and the Top Cover.
7
Reset the counter (see Reset the Usage Counters on page 188).
NOTE
Confirm the following items:
• The value of the Separation Pad Count is 0 (see Check Supplies Replacement Cycle on page 181).
• The error message on the Status Monitor has been cleared.
• The LCD or LED indications do not show Replace Pad or Replace Parts.
Replace the Pick-up Roller
Your machine is equipped with a scan counter. The counter automatically counts how many times the
machine has scanned. When the machine scans 50,000 times, the machine will display a message on the
Status Monitor to remind you to replace the Pick-up Roller.
1
Open the Top Cover a and the Front Cover s.
2
Hold the both sides of the Pick-up Roller Cover a and then pull the cover down.
a
s
a
8
8
185